Diagnostic meta-analysis of the efficacy of ultrasonography for diagnosing carpal tunnel syndrome: A comparison between Asian and non-Asian populations
Journal of the Formosan Medical Association · 2025-07 · 124 (7) · 666-674
DOI: 10.1016/j.jfma.2024.06.026 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of the Formosan Medical Association, 2025-07. Verfasst von Yan-Ting Luo und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical Medicine and Rehabilitation, Taipei Tzuchi Hospital, Buddhist Tzuchi Medical Foundation, New Taipei City, Taiwan. Hauptthemen laut MEDLINE: Asian People, Carpal Tunnel Syndrome, Median Nerve, Ultrasonography. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Taipei Tzu Chi Hospital, Center for Truth in Science, Buddhist Tzu Chi Medical Foundation.
Abstract (Originalsprache)
BACKGROUND: Ultrasonography is used to diagnose carpal tunnel syndrome (CTS) according to various criteria. This diagnostic meta-analysis aimed to evaluate the efficacy of ultrasonography for diagnosing CTS, focusing on the cross-sectional area (CSA) of the median nerve (MN) at the inlet of the carpal tunnel and regional variations in diagnostic thresholds between Asian and non-Asian populations. METHODS: A comprehensive literature search was conducted using PubMed, Embase, and the Cochrane Library. The risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2). Patient demographic data, diagnostic "gold standards", CSA cutoff values, and diagnostic results were extracted. Meta-analysis was performed to determine the sensitivity, specificity, and optimal CSA cutoff values. RESULTS: For the 25 included studies, a combined sensitivity of 88% and specificity of 84% for CSA measurements at the carpal tunnel inlet were obtained. The Asian group had a sensitivity of 84% and specificity of 86%, while the non-Asian group had a sensitivity of 91% and specificity of 82%. The mean CSA in the Asian group was significantly lower than that in the non-Asian group (12.93 mm2 and 14.77 mm2, respectively; p = 0.042). For the Asian group, the summary receiver operating characteristic curve had an area under the curve (AUC) of 0.92 with an optimal cutoff of 10.5 mm2; for the non-Asian group, an AUC of 0.94 was obtained with a cutoff of 11.5 mm2. CONCLUSION: Ultrasonography is a reliable diagnostic method for CTS, with distinct optimal cutoff values observed between Asian and non-Asian populations. Therefore, population-specific diagnostic criteria for CTS are recommended.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Physical Medicine and Rehabilitation, Taipei Tzuchi Hospital, Buddhist Tzuchi Medical Foundation, New Taipei City, Taiwan.
- Department of Physical Medicine and Rehabilitation, Taipei Tzuchi Hospital, Buddhist Tzuchi Medical Foundation, New Taipei City, Taiwan; Department of Medicine, Tzu Chi University, Hualien, Taiwan.
- Department of Physical Medicine and Rehabilitation, Taipei Tzuchi Hospital, Buddhist Tzuchi Medical Foundation, New Taipei City, Taiwan; Department of Medicine, Tzu Chi University, Hualien, Taiwan. Electronic address: y…
Förderung
- Taipei Tzu Chi Hospital
- Center for Truth in Science
- Buddhist Tzu Chi Medical Foundation
Zitieren
APA
Luo, Y. T., Huang, Y. T., Chiu, V., Chang, Y. W., & Horng, Y. S. (2025). Diagnostic meta-analysis of the efficacy of ultrasonography for diagnosing carpal tunnel syndrome: A comparison between Asian and non-Asian populations. Journal of the Formosan Medical Association, 124(7), 666-674. https://doi.org/10.1016/j.jfma.2024.06.026
Vancouver
Luo YT, Huang YT, Chiu V, Chang YW, Horng YS. Diagnostic meta-analysis of the efficacy of ultrasonography for diagnosing carpal tunnel syndrome: A comparison between Asian and non-Asian populations. Journal of the Formosan Medical Association. 2025;124(7):666-674. doi:10.1016/j.jfma.2024.06.026
BibTeX
@article{Luo2025,
author = {Luo, Yan-Ting and Huang, Yu-Ting and Chiu, Valeria and Chang, Yi-Wei and Horng, Yi-Shiung},
title = {Diagnostic meta-analysis of the efficacy of ultrasonography for diagnosing carpal tunnel syndrome: A comparison between Asian and non-Asian populations},
journal = {Journal of the Formosan Medical Association},
year = {2025},
volume = {124},
number = {7},
pages = {666--674},
doi = {10.1016/j.jfma.2024.06.026}
}
EUVIMED