Agreement of Temperatures Measured Using a Non-Contact Infrared Thermometer With a Rectal Digital Thermometer in Horses
Journal of Equine Veterinary Science · 2023
DOI: 10.1016/j.jevs.2023.104243 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Equine Veterinary Science, 2023. Verfasst von Leslie Easterwood und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Large Animal Clinical Sciences, Texas A&M University, College Station, TX. Electronic address: leasterwood@tamu.edu. Hauptthemen laut MEDLINE: Thermometers, Body Temperature. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 16 Literaturangaben.
Abstract (Originalsprache)
Evaluating the body temperature of horses is an essential tool for monitoring horse health and biosecurity in groups of horses. Temperatures of horses and foals are determined most often using rectal thermometry. Rectal thermometry has limitations that include safety considerations for horses and humans. Thus, we investigated the agreement between a noncontact infrared thermometer (NCIT) and a rectal digital thermometer in 142 horses and 34 foals. For each horse and foal, measurements using the NCIT were collected from the forehead (n = 2) or neck (n = 1) and with a rectal digital thermometer (n = 1). Although the NCIT demonstrated good reliability (i.e. repeatability of measurements), a large negative bias (nearly 2°F (-16.7°C) in adult horses and >3°F (-16.1°C) in foals) was observed between readings from the NCIT and the rectal thermometer in healthy horses. Although horses with febrile illness were not included in the study, our results indicate that the large and inconsistent bias observed with the NCIT indicates that these devices will not be a suitable substitute for rectal thermometry for obtaining valid estimates of core body temperature in horses.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Large Animal Clinical Sciences, Texas A&M University, College Station, TX. Electronic address: leasterwood@tamu.edu.
- Equine Infectious Disease Laboratory, Department of Large Animal Clinical Sciences, Texas A&M University, College Station, TX.
Zitieren
APA
Easterwood, L., & Cohen, N. D. (2023). Agreement of Temperatures Measured Using a Non-Contact Infrared Thermometer With a Rectal Digital Thermometer in Horses. Journal of Equine Veterinary Science. https://doi.org/10.1016/j.jevs.2023.104243
Vancouver
Easterwood L, Cohen ND. Agreement of Temperatures Measured Using a Non-Contact Infrared Thermometer With a Rectal Digital Thermometer in Horses. Journal of Equine Veterinary Science. 2023. doi:10.1016/j.jevs.2023.104243
BibTeX
@article{Easterwood2023,
author = {Easterwood, Leslie and Cohen, Noah D},
title = {Agreement of Temperatures Measured Using a Non-Contact Infrared Thermometer With a Rectal Digital Thermometer in Horses},
journal = {Journal of Equine Veterinary Science},
year = {2023},
doi = {10.1016/j.jevs.2023.104243}
}
EUVIMED