EUVIMEDEUVIMED entdecken
Crossref

Highly accurate calibration of particle number portable emissions measurement systems (PN-PEMS) via actual soot charging probability correction

Haotian Guo, Chengxiang Guo, Tongzhu Yu, Huaqiao Gui, Yixin Yang, Zhe Ji, Junjie Liu, Jiguang Wang, Jianguo Liu

Journal of Environmental Sciences · 2026

DOI: 10.1016/j.jes.2025.11.059 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Environmental Sciences, 2026. Verfasst von Haotian Guo und 8 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Environmental Optics and Technology, Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Ac…. Hauptthemen laut MEDLINE: Environmental Monitoring, Soot, Vehicle Emissions, Air Pollutants. Die Arbeit nennt 36 Literaturangaben. Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China, Engineering Laboratory.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The upcoming Euro 7 vehicle emissions regulation sets new requirements for calibrating particle number portable emissions measurement systems (PN-PEMS). In current PN concentration calibration methods, arbitrary selection of aerosol materials and incorrect estimation of multiply-charged particles lead to calibration deviation. This study proposes a novel, accurate calibration method based on the calibration and correction of the actual charging probability of soot for calibrating PN-PEMS. The accurate calibration results of a PN-PEMS show a maximum reduction of 7.65 % in the +1-charging probability deviation and of 3.15 % in the counting efficiency deviation. The calibration of the actual charging probability of soot introduces a calibration uncertainty increment of 0.09 %-2.71 %, and the overall uncertainty is < 4.76 %, which makes the calibration results more credible. The interaction of calibration aerosols of different physicochemical properties with the condensation particle counter working fluid and catalytic stripper device is the main reason for the different PN-PEMS calibration results. The calibration of the actual charging probability of particles is the fundamental method to eliminate the calibration deviation caused by the estimation and correction of multiply-charged particles.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Environmental MonitoringSootVehicle EmissionsAir PollutantsCalibrationAerosolsParticle Size

Stichwörter der Autor:innen

Accurate calibrationCharging probabilityMultiply-charged correctionParticle number (PN)Portable emissions measurement systems (PEMS)Soot

Substanzen

SootVehicle EmissionsAir PollutantsAerosols

Autor:innen und Institutionen

  • Key Laboratory of Environmental Optics and Technology, Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China; University of Science and Tech…
  • Key Laboratory of Environmental Optics and Technology, Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China; Institute of Environmental Hef…
  • Key Laboratory of Environmental Optics and Technology, Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China. Electronic address: yxyang@aio…
  • National Institute of Metrology, Beijing 100029, China.
  • China Automotive Technology and Research Center Co., Ltd., No. 68 Xianfeng East Road, Dongli District, Tianjin 300300, China.

Förderung

  • National Key Research and Development Program of China
  • National Natural Science Foundation of China
  • Engineering Laboratory

Zitieren

APA

Guo, H., Guo, C., Yu, T., Gui, H., Yang, Y., Ji, Z., Liu, J., Wang, J., & Liu, J. (2026). Highly accurate calibration of particle number portable emissions measurement systems (PN-PEMS) via actual soot charging probability correction. Journal of Environmental Sciences. https://doi.org/10.1016/j.jes.2025.11.059

Vancouver

Guo H, Guo C, Yu T, Gui H, Yang Y, Ji Z, et al. Highly accurate calibration of particle number portable emissions measurement systems (PN-PEMS) via actual soot charging probability correction. Journal of Environmental Sciences. 2026. doi:10.1016/j.jes.2025.11.059

BibTeX
@article{Guo2026,
  author = {Guo, Haotian and Guo, Chengxiang and Yu, Tongzhu and Gui, Huaqiao and Yang, Yixin and Ji, Zhe and Liu, Junjie and Wang, Jiguang and Liu, Jianguo},
  title = {Highly accurate calibration of particle number portable emissions measurement systems (PN-PEMS) via actual soot charging probability correction},
  journal = {Journal of Environmental Sciences},
  year = {2026},
  doi = {10.1016/j.jes.2025.11.059}
}
Kostenlos starten →