Highly accurate calibration of particle number portable emissions measurement systems (PN-PEMS) via actual soot charging probability correction
Journal of Environmental Sciences · 2026
DOI: 10.1016/j.jes.2025.11.059 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Environmental Sciences, 2026. Verfasst von Haotian Guo und 8 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Environmental Optics and Technology, Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Ac…. Hauptthemen laut MEDLINE: Environmental Monitoring, Soot, Vehicle Emissions, Air Pollutants. Die Arbeit nennt 36 Literaturangaben. Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China, Engineering Laboratory.
Abstract (Originalsprache)
The upcoming Euro 7 vehicle emissions regulation sets new requirements for calibrating particle number portable emissions measurement systems (PN-PEMS). In current PN concentration calibration methods, arbitrary selection of aerosol materials and incorrect estimation of multiply-charged particles lead to calibration deviation. This study proposes a novel, accurate calibration method based on the calibration and correction of the actual charging probability of soot for calibrating PN-PEMS. The accurate calibration results of a PN-PEMS show a maximum reduction of 7.65 % in the +1-charging probability deviation and of 3.15 % in the counting efficiency deviation. The calibration of the actual charging probability of soot introduces a calibration uncertainty increment of 0.09 %-2.71 %, and the overall uncertainty is < 4.76 %, which makes the calibration results more credible. The interaction of calibration aerosols of different physicochemical properties with the condensation particle counter working fluid and catalytic stripper device is the main reason for the different PN-PEMS calibration results. The calibration of the actual charging probability of particles is the fundamental method to eliminate the calibration deviation caused by the estimation and correction of multiply-charged particles.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Key Laboratory of Environmental Optics and Technology, Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China; University of Science and Tech…
- Key Laboratory of Environmental Optics and Technology, Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China; Institute of Environmental Hef…
- Key Laboratory of Environmental Optics and Technology, Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China. Electronic address: yxyang@aio…
- National Institute of Metrology, Beijing 100029, China.
- China Automotive Technology and Research Center Co., Ltd., No. 68 Xianfeng East Road, Dongli District, Tianjin 300300, China.
Förderung
- National Key Research and Development Program of China
- National Natural Science Foundation of China
- Engineering Laboratory
Zitieren
APA
Guo, H., Guo, C., Yu, T., Gui, H., Yang, Y., Ji, Z., Liu, J., Wang, J., & Liu, J. (2026). Highly accurate calibration of particle number portable emissions measurement systems (PN-PEMS) via actual soot charging probability correction. Journal of Environmental Sciences. https://doi.org/10.1016/j.jes.2025.11.059
Vancouver
Guo H, Guo C, Yu T, Gui H, Yang Y, Ji Z, et al. Highly accurate calibration of particle number portable emissions measurement systems (PN-PEMS) via actual soot charging probability correction. Journal of Environmental Sciences. 2026. doi:10.1016/j.jes.2025.11.059
BibTeX
@article{Guo2026,
author = {Guo, Haotian and Guo, Chengxiang and Yu, Tongzhu and Gui, Huaqiao and Yang, Yixin and Ji, Zhe and Liu, Junjie and Wang, Jiguang and Liu, Jianguo},
title = {Highly accurate calibration of particle number portable emissions measurement systems (PN-PEMS) via actual soot charging probability correction},
journal = {Journal of Environmental Sciences},
year = {2026},
doi = {10.1016/j.jes.2025.11.059}
}
EUVIMED