Cement-mortar lining failure and metal release caused by electrochemical corrosion of ductile iron pipes in drinking water distribution systems

Hao Guo, Rui Wang, Menghan Jiang, Yimei Tian, Yapeng Jin, Weigao Zhao, Chenwan Wang, Jianhua Yin

Journal of Environmental Sciences · 2025-06 · 152 · 488-502

DOI: 10.1016/j.jes.2024.06.003 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Environmental Sciences, 2025-06. Verfasst von Hao Guo und 7 weiteren Autor:innen. Beteiligte Einrichtung: The Institute of Seawater Desalination and Multipurpose Utilization, MNR (Tianjin), Tianjin 300192, China. Electronic address: guohao@isdmu.com.cn. Hauptthemen laut MEDLINE: Drinking Water, Iron, Water Pollutants, Chemical, Water Supply. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 56 Literaturangaben. Gefördert von: Natural Science Foundation of Tianjin Municipality, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The electrochemical corrosion of ductile pipes (DPs) in drinking water distribution systems (DWDS) has a crucial impact on cement-mortar lining (CML) failure and metal release, potentially leading to drinking water quality deterioration and posing a risk to public health. An in-situ scanning vibrating electrode technique (SVET) with micron-scale resolution, microscopic scale detection and water quality analysis were used to investigate the corrosion behavior and metal release from DPs throughout the whole CML failure process. Metal pollutants release occurred at three different stages of CML failure process, and there are potential risks of water quality deterioration exceeding the maximum allowable levels set by national standards in the partial failure stage and lining peeling stage. Furthermore, the effects of water chemistry (Cl-, SO42-, NO3-, and Ca2+) on corrosion scale growth and iron release activity, were investigated during the CML partial failure stage. Results showed that the CML failure process in DPs was accelerated by the autocatalysis of localized corrosion. Cl- was found to damage the uncorroded metal surface, while SO42- mainly dissolved the corrosion scale surface, increasing iron release. Both the oxidation of NO3- and selective sedimentation of Ca2+ were found to enhance the stability of corrosion scales and inhibit iron release.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Drinking WaterIronWater Pollutants, ChemicalWater SupplyCorrosionConstruction MaterialsMetalsEnvironmental Monitoring

Stichwörter der Autor:innen

Cement mortar liningCorrosionMetal releaseSVETWater distribution system

Substanzen

Drinking WaterIronWater Pollutants, ChemicalMetals

Autor:innen und Institutionen

  • The Institute of Seawater Desalination and Multipurpose Utilization, MNR (Tianjin), Tianjin 300192, China. Electronic address: guohao@isdmu.com.cn.
  • Shandong Huankeyuan Environmental Engineering Co., Ltd., Jinan 250000, China.
  • School of Environmental Science and Engineering, Tianjin University, Tianjin 300350, China.
  • The Institute of Seawater Desalination and Multipurpose Utilization, MNR (Tianjin), Tianjin 300192, China.
  • School of Environmental Science and Safety Engineering, Tianjin University of Technology, Tianjin 300384, China.

Förderung

  • Natural Science Foundation of Tianjin Municipality
  • National Natural Science Foundation of China

Zitieren

APA

Guo, H., Wang, R., Jiang, M., Tian, Y., Jin, Y., Zhao, W., Wang, C., & Yin, J. (2025). Cement-mortar lining failure and metal release caused by electrochemical corrosion of ductile iron pipes in drinking water distribution systems. Journal of Environmental Sciences, 152, 488-502. https://doi.org/10.1016/j.jes.2024.06.003

Vancouver

Guo H, Wang R, Jiang M, Tian Y, Jin Y, Zhao W, et al. Cement-mortar lining failure and metal release caused by electrochemical corrosion of ductile iron pipes in drinking water distribution systems. Journal of Environmental Sciences. 2025;152:488-502. doi:10.1016/j.jes.2024.06.003

BibTeX
@article{Guo2025,
  author = {Guo, Hao and Wang, Rui and Jiang, Menghan and Tian, Yimei and Jin, Yapeng and Zhao, Weigao and Wang, Chenwan and Yin, Jianhua},
  title = {Cement-mortar lining failure and metal release caused by electrochemical corrosion of ductile iron pipes in drinking water distribution systems},
  journal = {Journal of Environmental Sciences},
  year = {2025},
  volume = {152},
  pages = {488--502},
  doi = {10.1016/j.jes.2024.06.003}
}