EUVIMEDEUVIMED entdecken
Crossref

Construction of eco-friendly dual carbon dots ratiometric fluorescence probe for highly selective and efficient sensing mercury ion

Yongli Liu, Xiaoyan Su, Huanjia Liu, Guifen Zhu, Guobei Ge, Yuxin Wang, Penghui Zhou, Qingxiang Zhou

Journal of Environmental Sciences · 2025-02 · 148 · 1-12

DOI: 10.1016/j.jes.2024.01.013 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Environmental Sciences, 2025-02. Verfasst von Yongli Liu und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Environment, Henan Key Laboratory for Environmental Pollution Control, Key Laboratory for Yellow River and Huai River Water Environmental a…. Hauptthemen laut MEDLINE: Mercury, Carbon, Fluorescent Dyes, Water Pollutants, Chemical. Die Arbeit wurde bisher 49-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: Henan Normal University, National Natural Science Foundation of China, Youth Science Foundation of Henan Normal University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In present work, blue carbon dots (b-CDs) were derived from ammonium citrate and guanidine hydrochloride, and red carbon dots (r-CDs) were stemmed from malonate, ethylenediamine and meso‑tetra (4-carboxyphenyl) porphin based on facile hydrothermal method. Eco-friendly ratiometric fluorescence probe was innovatively constructed to effectively measure Hg2+ utilizing b-CDs and r-CDs. The developed probe displayed two typical emission peaks at 450 nm from b-CDs and 650 nm from r-CDs under the excitation at 360 nm. Mercury ion has strong quenching effect on the fluorescence intensity at 450 nm due to the electron transfer process and the fluorescence change at 450 nm was used as the response signal, whereas the fluorescence intensity at 650 nm kept unchangeable which resulted from the chemical inertness between Hg2+ and r-CDs, serving as the reference signal in the sensing system. Under optimal circumstances, this probe exhibited an excellent linearity between the fluorescence response values of ΔF450/F650 and Hg2+ concentrations over range of 0.01-10 µmol/L, and the limit of detection was down to 5.3 nmol/L. Furthermore, this probe was successfully employed for sensing Hg2+ in practical environmental water samples with satisfied recoveries of 98.5%-105.0%. The constructed ratiometric fluorescent probe provided a rapid, environmental-friendly, reliable, and efficient platform for measuring trace Hg2+ in environmental field.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MercuryCarbonFluorescent DyesWater Pollutants, ChemicalQuantum DotsEnvironmental MonitoringSpectrometry, FluorescenceLimit of DetectionFluorescence

Stichwörter der Autor:innen

Blue carbon dotsEco-friendlinessElectron transferHg(2+)Red carbon dots

Substanzen

MercuryCarbonFluorescent DyesWater Pollutants, Chemical

Autor:innen und Institutionen

  • School of Environment, Henan Key Laboratory for Environmental Pollution Control, Key Laboratory for Yellow River and Huai River Water Environmental and Pollution Control, Ministry of Education, Henan Normal University,…
  • College of Chemical Engineering and Environment, China University of Petroleum-Beijing, Beijing 102249, China. Electronic address: zhouqx@cup.edu.cn.

Förderung

  • Henan Normal University
  • National Natural Science Foundation of China
  • Youth Science Foundation of Henan Normal University
  • Science and Technology Innovation Talents in Universities of Henan Province

Zitieren

APA

Liu, Y., Su, X., Liu, H., Zhu, G., Ge, G., Wang, Y., Zhou, P., & Zhou, Q. (2025). Construction of eco-friendly dual carbon dots ratiometric fluorescence probe for highly selective and efficient sensing mercury ion. Journal of Environmental Sciences, 148, 1-12. https://doi.org/10.1016/j.jes.2024.01.013

Vancouver

Liu Y, Su X, Liu H, Zhu G, Ge G, Wang Y, et al. Construction of eco-friendly dual carbon dots ratiometric fluorescence probe for highly selective and efficient sensing mercury ion. Journal of Environmental Sciences. 2025;148:1-12. doi:10.1016/j.jes.2024.01.013

BibTeX
@article{Liu2025,
  author = {Liu, Yongli and Su, Xiaoyan and Liu, Huanjia and Zhu, Guifen and Ge, Guobei and Wang, Yuxin and Zhou, Penghui and Zhou, Qingxiang},
  title = {Construction of eco-friendly dual carbon dots ratiometric fluorescence probe for highly selective and efficient sensing mercury ion},
  journal = {Journal of Environmental Sciences},
  year = {2025},
  volume = {148},
  pages = {1--12},
  doi = {10.1016/j.jes.2024.01.013}
}
Kostenlos starten →