Numerical simulation study of indoor disinfection spray distribution based on CFD-DPM method
Journal of Engineering Research · 2024-09 · 12 (3) · 562-570
DOI: 10.1016/j.jer.2023.10.039 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Engineering Research, 2024-09. Verfasst von Ye Lu und 3 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Shanghai Rising-Star Program, Shanghai Science and Technology Development Foundation.
Abstract (Originalsprache)
In today's world, environmental safety has become a top priority, with a special focus on terminal disinfection of indoor environments, which has proven to be a crucial and formidable issue in infection control. The use of hydrogen peroxide disinfection through vaporization or atomization presents a viable solution to the challenges posed by traditional wiping disinfection and ultraviolet disinfection methods that are plagued by incomplete disinfection and other factors that can significantly reduce the virus content within a room. To improve the application of hydrogen peroxide disinfection spray, the CFD-DPM (Computational Fluid Dynamics-Discrete Particle Model) method is employed to simulate the particle distribution of traditional sprays in a 30m3 room. The study places emphasis on analyzing the impact of the placement position and bottle number of disinfection spray on the distribution of spray particles. The results demonstrate an impressive consistency between the numerical simulation method and experimental findings regarding the particle size distribution of disinfectant spray across various Schemes, validating the method's accuracy and reliability. However, the placement of a single disinfection spray source is insufficient to achieve uniformly distributed particles throughout the space when a bathroom is present within a given room. Nevertheless, by placing internal and external sources within the bathroom, the distribution of disinfectant spray particles becomes more even, thanks to a well conceived placement technique and an increased number of spray sources. Among all the schemes tested, Scheme 4 stands out for its ability to produce the greatest number of spray particles, with almost 60.71% of these particles remaining airborne for over 40 seconds. Therefore, it is also the most effective scheme for conducting disinfection.
Förderung
- Shanghai Rising-Star Program
- Shanghai Science and Technology Development Foundation
Zitieren
APA
Lu, Y., Li, S., Xu, W., & Wang, Y. (2024). Numerical simulation study of indoor disinfection spray distribution based on CFD-DPM method. Journal of Engineering Research, 12(3), 562-570. https://doi.org/10.1016/j.jer.2023.10.039
Vancouver
Lu Y, Li S, Xu W, Wang Y. Numerical simulation study of indoor disinfection spray distribution based on CFD-DPM method. Journal of Engineering Research. 2024;12(3):562-570. doi:10.1016/j.jer.2023.10.039
BibTeX
@article{Lu2024,
author = {Lu, Ye and Li, Shen and Xu, Wen and Wang, Ying},
title = {Numerical simulation study of indoor disinfection spray distribution based on CFD-DPM method},
journal = {Journal of Engineering Research},
year = {2024},
volume = {12},
number = {3},
pages = {562--570},
doi = {10.1016/j.jer.2023.10.039}
}