A new methodology for the evaluation of radon diffusion coefficients in anti-radon membranes
Journal of Environmental Radioactivity · 2025-07 · 287 · 107708
DOI: 10.1016/j.jenvrad.2025.107708 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Environmental Radioactivity, 2025-07. Verfasst von Manuela Portaro und 6 weiteren Autor:innen. Beteiligte Einrichtung: Università degli Studi "Roma Tre", Dipartimento di Scienze, Largo San Leonardo Murialdo 1, 00146, Roma, Italy. Electronic address: manuela.portaro@un…. Hauptthemen laut MEDLINE: Radon, Air Pollutants, Radioactive, Radiation Monitoring, Air Pollution, Indoor. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Università degli Studi Roma Tre, Ministero dell’Istruzione, dell’Università e della Ricerca, Dipartimento di Scienze, Università degli Studi Roma Tre.
Abstract (Originalsprache)
Indoor radon is classified as a carcinogen because it can lead to lung cancer. Some radon preventive strategies are related to building protection with radon barrier materials whose capacity to stop the gas depends on the diffusion coefficient, which can be calculated using different techniques. In this article, we propose a new experimental device, called TESTMAT, to measure the radon diffusion coefficient, using a weak radon source, to prevent radiation protection oversight. The device is small and made from PVC. The sample of the tested material is placed between the source and the receiver containers, as indicated by ISO/TS 11665-13 standard. Since a non-stationary radon diffusion occurs in the system, we developed a specific software, ENDORSE, to model radon activity concentrations in the receiver chamber and the diffusion through the material by applying the explicit finite difference method. The software utilizes Montecarlo simulation to determine the error associated with the diffusion coefficient. Different tests were performed to calibrate the system and assess the value and the evolution of background radon during the two-week measurement. When working with low-activity radon sources, this parameter cannot be neglected, particularly with the best performing membranes. An adequate sample holder was selected to guarantee a good airtightness, with a leakage constant of only 7 % of the radon decay constant. The minimum detection limits were calculated based on the material thickness and the source intensity. The system was finally tested with three commercially available waterproofing membranes and results compared with expected values, based on literature.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Università degli Studi "Roma Tre", Dipartimento di Scienze, Largo San Leonardo Murialdo 1, 00146, Roma, Italy. Electronic address: manuela.portaro@uniroma3.it.
- Università degli Studi "Roma Tre", Dipartimento di Scienze, Largo San Leonardo Murialdo 1, 00146, Roma, Italy. Electronic address: ilaria.rocchetti@uniroma3.it.
- Istituto Nazionale Geofisica e Vulcanologia, Sezione Roma 1, Via Vigna Murata 605, 00143, Roma, Italy. Electronic address: gianfranco.galli@ingv.it.
- Università degli Studi "Roma Tre", Dipartimento di Scienze, Largo San Leonardo Murialdo 1, 00146, Roma, Italy. Electronic address: paola.tuccimei@uniroma3.it.
- Università degli Studi "Roma Tre", Dipartimento di Scienze, Largo San Leonardo Murialdo 1, 00146, Roma, Italy. Electronic address: michele.soligo@uniroma3.it.
- Mapei S.p.A, Waterproofing Line, Via Carlo Cafiero 22, 20158, Milano, Italy. Electronic address: c.longoni@mapei.it.
Förderung
- Università degli Studi Roma Tre
- Ministero dell’Istruzione, dell’Università e della Ricerca
- Dipartimento di Scienze, Università degli Studi Roma Tre
Zitieren
APA
Portaro, M., Rocchetti, I., Galli, G., Tuccimei, P., Soligo, M., Longoni, C., & Vasquez, D. (2025). A new methodology for the evaluation of radon diffusion coefficients in anti-radon membranes. Journal of Environmental Radioactivity, 287, 107708. https://doi.org/10.1016/j.jenvrad.2025.107708
Vancouver
Portaro M, Rocchetti I, Galli G, Tuccimei P, Soligo M, Longoni C, et al. A new methodology for the evaluation of radon diffusion coefficients in anti-radon membranes. Journal of Environmental Radioactivity. 2025;287:107708. doi:10.1016/j.jenvrad.2025.107708
BibTeX
@article{Portaro2025,
author = {Portaro, Manuela and Rocchetti, Ilaria and Galli, Gianfranco and Tuccimei, Paola and Soligo, Michele and Longoni, Cristina and Vasquez, Dino},
title = {A new methodology for the evaluation of radon diffusion coefficients in anti-radon membranes},
journal = {Journal of Environmental Radioactivity},
year = {2025},
volume = {287},
pages = {107708},
doi = {10.1016/j.jenvrad.2025.107708}
}
EUVIMED