Polarity reversal enabled copper cycling in an electro-Fenton-based combined system for suppressed Cu(II) release and enhanced BPA degradation
Journal of Environmental Management · 2026-04 · 403 · 129241
DOI: 10.1016/j.jenvman.2026.129241 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Environmental Management, 2026-04. Verfasst von Zhi Xu und 8 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemical Engineering, Northeast Electric Power University, Jilin, 132012, China. Hauptthemen laut MEDLINE: Copper, Benzhydryl Compounds, Phenols, Water Pollutants, Chemical. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 50 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Copper-based Fenton-like technology is promising for wastewater treatment but is bottlenecked by Cu(II) secondary pollution. This study integrates electrode polarity reversal into a copper-based electro-Fenton system to achieve active "rocking-chair" copper ion cycling between electrodes. In contrast to conventional passive supplementation, this strategy represents the first report of its specific combination and successfully converts Cu(II) from an environmental liability into a recyclable resource. A single polarity reversal at 30 min increased BPA removal from 83.6% to 93.8%, while reducing effluent Cu(II) from 13.6 mg/L to 1.6 mg/L. A coupled Fenton-like/electro-Fenton reactor further improved performance; with optimized reversal frequency and a three-electrode design, BPA removal reached 93.4% and 91.6% in the two units, and residual Cu(II) dropped to as low as 0.53 mg/L. Mechanistically, polarity reversal enhanced singlet oxygen generation by 1.2-fold, and 2DCOS analysis revealed preferential degradation of protein-like substances in real wastewater. Validation with real wastewater confirmed the system's stability and practical feasibility. This work turns the longstanding issue of Cu(II) pollution into a recyclable resource, offering a simple, cost-effective, and sustainable polarity reversal strategy that advances the practical application of Fenton-like technology in real wastewater treatment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Chemical Engineering, Northeast Electric Power University, Jilin, 132012, China.
- School of Chemical Engineering, Northeast Electric Power University, Jilin, 132012, China. Electronic address: cyteng@neepu.edu.cn.
- School of Chemical Engineering, Northeast Electric Power University, Jilin, 132012, China. Electronic address: zhftju@163.com.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Xu, Z., Xiong, W., Zhou, C., Liu, Z., Teng, C., Wang, Z., Lv, H., Zhang, M., & Zhang, H. (2026). Polarity reversal enabled copper cycling in an electro-Fenton-based combined system for suppressed Cu(II) release and enhanced BPA degradation. Journal of Environmental Management, 403, 129241. https://doi.org/10.1016/j.jenvman.2026.129241
Vancouver
Xu Z, Xiong W, Zhou C, Liu Z, Teng C, Wang Z, et al. Polarity reversal enabled copper cycling in an electro-Fenton-based combined system for suppressed Cu(II) release and enhanced BPA degradation. Journal of Environmental Management. 2026;403:129241. doi:10.1016/j.jenvman.2026.129241
BibTeX
@article{Xu2026,