Synergistic effects of Cl−/SO42− and sulfate-reducing bacteria on the grounding grid corrosion: performance, metabolites and mechanisms
Journal of Environmental Management · 2026
DOI: 10.1016/j.jenvman.2026.128807 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Environmental Management, 2026. Verfasst von Yuxian Zhang und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemical Engineering, Northeast Electric Power University, Jilin, 132012, China. Hauptthemen laut MEDLINE: Sulfates, Bacteria. Die Arbeit nennt 83 Literaturangaben. Gefördert von: State Grid Jilin Electric Power.
Abstract (Originalsprache)
The grounding grid of transmission equipment suffers corrosion due to abundant soil anions and microorganisms, posing a risk to the power system. In this study, the effects of different concentration ratio of Cl-/SO42- and sulfate-reducing bacteria (SRB) on the corrosion of grounding grid were investigated, and the chemical-biological coupling corrosion patterns in complex environments were revealed. The results showed that corrosion rate of Q235 steel was improved with the increase of Cl-/SO42- concentration ratio. The maximum Icorr value of 159.650 μA cm-2 and the most severe corrosion of Q235 steel were observed at a Cl-/SO42- concentration ratio of 5. In contrast, the corrosion rate of galvanized steel exhibited an initial increase followed by a decrease with the rising concentration ratio of Cl-/SO42-. The Icorr reached the maximum value of 7.332 μA cm-2 when the concentration ratio of Cl-/SO42- was 7.5. Under the protection of the galvanized layer, the overall corrosion rate of galvanized steel was significantly lower than that of Q235 steel. The Cl- preferentially entered oxide film voids and accelerated metal dissolution due to its small ionic radius and strong penetration ability. The SO42- could promote the cathodic depolarization process of SRB and facilitate anodic metal dissolution. The results of this study have important guiding significance for the protection of grounding metal corrosion in the soil and the timely adjustment of control measures.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Chemical Engineering, Northeast Electric Power University, Jilin, 132012, China.
- School of Chemical Engineering, Northeast Electric Power University, Jilin, 132012, China. Electronic address: zhanglanhe@163.com.
- School of Hydraulic Engineering, Guangxi Vocational College of Water Resources and Electric Power, Nanning, 530023, China.
- School of Chemical Engineering, Northeast Electric Power University, Jilin, 132012, China. Electronic address: zhangmingshuangtg@163.com.
Förderung
- State Grid Jilin Electric Power
Zitieren
APA
Zhang, Y., Zhang, L., Liu, H., Zhang, M., & Li, K. (2026). Synergistic effects of Cl−/SO42− and sulfate-reducing bacteria on the grounding grid corrosion: performance, metabolites and mechanisms. Journal of Environmental Management. https://doi.org/10.1016/j.jenvman.2026.128807
Vancouver
Zhang Y, Zhang L, Liu H, Zhang M, Li K. Synergistic effects of Cl−/SO42− and sulfate-reducing bacteria on the grounding grid corrosion: performance, metabolites and mechanisms. Journal of Environmental Management. 2026. doi:10.1016/j.jenvman.2026.128807
BibTeX
@article{Zhang2026,
author = {Zhang, Yuxian and Zhang, Lanhe and Liu, Hui and Zhang, Mingshuang and Li, Keke},
title = {Synergistic effects of Cl−/SO42− and sulfate-reducing bacteria on the grounding grid corrosion: performance, metabolites and mechanisms},
journal = {Journal of Environmental Management},
year = {2026},
doi = {10.1016/j.jenvman.2026.128807}
}
EUVIMED