Preparation of Ti/RuO2-IrO2 electrodes and their application in broad-spectrum electrochemical detection of COD
Journal of Environmental Management · 2025
DOI: 10.1016/j.jenvman.2025.124699 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Environmental Management, 2025. Verfasst von Yanhe Han und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Environmental Engineering, Beijing Institute of Petrochemical Technology, Beijing 102617, China. Electronic address: hanyanhe@bipt.edu.…. Hauptthemen laut MEDLINE: Biological Oxygen Demand Analysis, Electrochemical Techniques. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 61 Literaturangaben. Gefördert von: Beijing Municipal Commission of Education, Natural Science Foundation of Beijing Municipality, National Natural Science Foundation of China.
Abstract (Originalsprache)
An electrode with RuO2 and IrO2 co-deposited on a Ti surface (Ti/RuO2-IrO2), notable for its high catalytic activity and stability, was developed for the rapid and environmentally friendly electrochemical determination of chemical oxygen demand (COD). This study thoroughly examined factors influencing electrode preparation, COD detection mechanisms, and the factors affecting COD detection, as well as broad-spectrum analysis. Under optimal conditions, which include a deposition time of 53.5 min, a current density of 5.5 mA/cm2, and 2.35 mmol of RuCl3, the electrode achieved a linear correlation coefficient of 0.99 for COD detection. The co-doping of RuO2 and IrO2 significantly enhanced the electrode's specific surface area and charge transfer rate, thereby improving the oxidation of organic compounds. The detection limit for COD was established at 1.8 mg/L, with a range of 0-250 mg/L, using an oxidation potential of 0.90 V and an electrolysis time of 150 s at an initial electrolyte pH of 6 with 0.03 mol/L NaNO3. The electrode effectively oxidized organic compounds across this range and demonstrated tolerance to chloride concentrations up to 800 mg/L. Electrode stability was confirmed through 30 repetitive cycles with no significant performance degradation. The detection results for simulated water samples were in strong agreement with the results obtained from the dichromate colorimetric method, with a linear equation of y = 0.01x+1.11, with an R2 of 0.99. The detection outcomes for six different sources of real water samples indicated consistent correlation between the electrochemical COD detection method using the Ti/RuO2-IrO2 electrode and the dichromate colorimetric method. This research showed the Ti/RuO2-IrO2 electrode has certain potential as COD detection element, leveraging its high charge transfer rate and extensive active area.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Environmental Engineering, Beijing Institute of Petrochemical Technology, Beijing 102617, China. Electronic address: hanyanhe@bipt.edu.cn.
- Department of Environmental Engineering, Beijing Institute of Petrochemical Technology, Beijing 102617, China.
- Baoding Hualian Top Technology, Hebei 071000, China.
- Department of Environmental Engineering, Beijing Institute of Petrochemical Technology, Beijing 102617, China. Electronic address: maxuejiao@bipt.edu.cn.
Förderung
- Beijing Municipal Commission of Education
- Natural Science Foundation of Beijing Municipality
- National Natural Science Foundation of China
Zitieren
APA
Han, Y., Zhao, Q., Liu, T., Liu, L., Ma, X., & Wang, N. (2025). Preparation of Ti/RuO2-IrO2 electrodes and their application in broad-spectrum electrochemical detection of COD. Journal of Environmental Management. https://doi.org/10.1016/j.jenvman.2025.124699
Vancouver
Han Y, Zhao Q, Liu T, Liu L, Ma X, Wang N. Preparation of Ti/RuO2-IrO2 electrodes and their application in broad-spectrum electrochemical detection of COD. Journal of Environmental Management. 2025. doi:10.1016/j.jenvman.2025.124699
BibTeX
@article{Han2025,
author = {Han, Yanhe and Zhao, Qingpeng and Liu, Ting and Liu, Lina and Ma, Xuejiao and Wang, Nannan},
title = {Preparation of Ti/RuO2-IrO2 electrodes and their application in broad-spectrum electrochemical detection of COD},
journal = {Journal of Environmental Management},
year = {2025},
doi = {10.1016/j.jenvman.2025.124699}
}