Comparative study of different ultrasound based hybrid oxidation approaches for treatment of real effluent from coke oven plant
Journal of Environmental Management · 2024
DOI: 10.1016/j.jenvman.2024.120095 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Environmental Management, 2024. Verfasst von Ananya Dey und 1 weiteren Autor:innen. Beteiligte Einrichtung: Chemical Engineering Department, Institute of Chemical Technology, Matunga, Mumbai, 400 019, India. Hauptthemen laut MEDLINE: Coke, Ozone, Water Pollutants, Chemical. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 73 Literaturangaben.
Abstract (Originalsprache)
The present study investigates the treatment of real coke plant effluent utilising several ultrasound-based hybrid oxidation approaches including Ultrasound (US) alone, US + catalyst, US + H2O2, US + Fenton, US + Ozone, and US + Peroxone, with main objective as maximizing the reduction of chemical oxygen demand (COD). Ultrasonic horn at power of 130 W, frequency as 20 kHz and duty cycle as 70% was applied. Study with varying catalyst (TiO2) dose from 0.5 g/L - 2 g/L revealed 1 g/L as the optimum dose resulting in 65.15% reduction in COD. A 40 ml/L dose of H2O2 was shown to be optimal, giving an 81.96% reduction in COD, based on the study of varied doses of H2O2 from 20 ml/L to 60 ml/L. US + Fenton reagent combination at optimum Fe2+/H2O2 (w/v) ratio of 1:1 resulted in a COD reduction of 85.29% whereas reduction of COD as 81.75% was obtained at the optimum flow rate of ozone as 1 LPM for US + Ozone approach. US + Peroxone demonstrated the best efficiency (90.48%) for COD reduction. To find the toxicity effects, the treated (US + peroxone) and non-treated samples were tested for the growth of bacterial cultures. It was observed that the toxicity of the treated sample increased only marginally after treatment. High-resolution liquid chromatography mass spectrometry (HR-LCMS) analysis was also performed to establish intermediate compounds. Overall, the coupling of ultrasound with oxidation processes produced better results with US + Peroxone established as best treatment approach for coke plant effluent.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Chemical Engineering Department, Institute of Chemical Technology, Matunga, Mumbai, 400 019, India.
- Chemical Engineering Department, Institute of Chemical Technology, Matunga, Mumbai, 400 019, India. Electronic address: pr.gogate@ictmumbai.edu.in.
Zitieren
APA
Dey, A., & Gogate, P. R. (2024). Comparative study of different ultrasound based hybrid oxidation approaches for treatment of real effluent from coke oven plant. Journal of Environmental Management. https://doi.org/10.1016/j.jenvman.2024.120095
Vancouver
Dey A, Gogate PR. Comparative study of different ultrasound based hybrid oxidation approaches for treatment of real effluent from coke oven plant. Journal of Environmental Management. 2024. doi:10.1016/j.jenvman.2024.120095
BibTeX
@article{Dey2024,
author = {Dey, Ananya and Gogate, Parag R},
title = {Comparative study of different ultrasound based hybrid oxidation approaches for treatment of real effluent from coke oven plant},
journal = {Journal of Environmental Management},
year = {2024},
doi = {10.1016/j.jenvman.2024.120095}
}
EUVIMED