EUVIMEDEUVIMED entdecken
Crossref

Comparative study of different ultrasound based hybrid oxidation approaches for treatment of real effluent from coke oven plant

Ananya Dey, Parag R Gogate

Journal of Environmental Management · 2024

DOI: 10.1016/j.jenvman.2024.120095 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Environmental Management, 2024. Verfasst von Ananya Dey und 1 weiteren Autor:innen. Beteiligte Einrichtung: Chemical Engineering Department, Institute of Chemical Technology, Matunga, Mumbai, 400 019, India. Hauptthemen laut MEDLINE: Coke, Ozone, Water Pollutants, Chemical. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 73 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The present study investigates the treatment of real coke plant effluent utilising several ultrasound-based hybrid oxidation approaches including Ultrasound (US) alone, US + catalyst, US + H2O2, US + Fenton, US + Ozone, and US + Peroxone, with main objective as maximizing the reduction of chemical oxygen demand (COD). Ultrasonic horn at power of 130 W, frequency as 20 kHz and duty cycle as 70% was applied. Study with varying catalyst (TiO2) dose from 0.5 g/L - 2 g/L revealed 1 g/L as the optimum dose resulting in 65.15% reduction in COD. A 40 ml/L dose of H2O2 was shown to be optimal, giving an 81.96% reduction in COD, based on the study of varied doses of H2O2 from 20 ml/L to 60 ml/L. US + Fenton reagent combination at optimum Fe2+/H2O2 (w/v) ratio of 1:1 resulted in a COD reduction of 85.29% whereas reduction of COD as 81.75% was obtained at the optimum flow rate of ozone as 1 LPM for US + Ozone approach. US + Peroxone demonstrated the best efficiency (90.48%) for COD reduction. To find the toxicity effects, the treated (US + peroxone) and non-treated samples were tested for the growth of bacterial cultures. It was observed that the toxicity of the treated sample increased only marginally after treatment. High-resolution liquid chromatography mass spectrometry (HR-LCMS) analysis was also performed to establish intermediate compounds. Overall, the coupling of ultrasound with oxidation processes produced better results with US + Peroxone established as best treatment approach for coke plant effluent.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CokeOzoneWater Pollutants, ChemicalHydrogen PeroxideWaste Disposal, FluidOxidation-Reduction

Stichwörter der Autor:innen

Advanced oxidation processes (AOPs)Coke plant effluentCost estimationHybrid treatment approachesToxicity analysisUltrasound

Substanzen

Hydrogen PeroxideCokeOzoneWater Pollutants, Chemical

Autor:innen und Institutionen

  • Chemical Engineering Department, Institute of Chemical Technology, Matunga, Mumbai, 400 019, India.
  • Chemical Engineering Department, Institute of Chemical Technology, Matunga, Mumbai, 400 019, India. Electronic address: pr.gogate@ictmumbai.edu.in.

Zitieren

APA

Dey, A., & Gogate, P. R. (2024). Comparative study of different ultrasound based hybrid oxidation approaches for treatment of real effluent from coke oven plant. Journal of Environmental Management. https://doi.org/10.1016/j.jenvman.2024.120095

Vancouver

Dey A, Gogate PR. Comparative study of different ultrasound based hybrid oxidation approaches for treatment of real effluent from coke oven plant. Journal of Environmental Management. 2024. doi:10.1016/j.jenvman.2024.120095

BibTeX
@article{Dey2024,
  author = {Dey, Ananya and Gogate, Parag R},
  title = {Comparative study of different ultrasound based hybrid oxidation approaches for treatment of real effluent from coke oven plant},
  journal = {Journal of Environmental Management},
  year = {2024},
  doi = {10.1016/j.jenvman.2024.120095}
}
Kostenlos starten →