EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Influence of operator experience on the complete-arch accuracy and time-based efficiency of three intraoral scanners

Wei-Chun Lin, Chian-Chuen Lee, Sheng-Yang Lee, Chiao-Yun Peng, Chia-Cheng Lin

Journal of Dental Sciences · 2025-01 · 20 (1) · 620-625

DOI: 10.1016/j.jds.2024.11.009 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Dental Sciences, 2025-01. Verfasst von Wei-Chun Lin und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Dental Technology, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Shin Kong Wu Ho Su Memorial Hospital.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/purpose: The performance of intraoral scanners (IOSs) relies on the operator's skills. However, whether operator experience influences IOS accuracy remains unclear. This study investigated the effect of operator experience on the trueness accuracy and time-based efficiency of IOSs. Materials and methods: Thirty operators were equally divided into two groups on the basis of their IOS-handling experience. Each operator performed simulation scans of a maxillary model in a training dummy by using three IOSs: CEREC Omnicam, Primescan, and Aoralscan 3. A total of 90 scans were generated, and the scan time for image acquisition and the render time required for an IOS to generate a three-dimensional image were recorded. The trueness of each scan was calculated by comparing with a reference scan obtained from an industrial high-precision scanner. The t test and the ANOVA followed by the Tukey post hoc test were used to determine statistical differences. Significance was set at P < 0.01.

Results

For the three IOSs, no significant difference was noted in trueness accuracy, scan time, or render time between inexperienced and experienced operators. For both inexperienced and experienced operators, Omnicam had significantly less accuracy and longer scan time than did the other IOSs; the render time was significantly shorter for Aoralscan 3 than for the other IOSs.

Conclusion

Operator experience does not substantially influence the trueness accuracy and time-based efficiency of IOSs; these factors vary across IOS types. The render time for obtaining three-dimensional images is a significant feature for improving the time-based efficiency of IOSs.

Schlagwörter

Stichwörter der Autor:innen

AccuracyDigital impressionIntraoral scannerScan timeTrueness

Autor:innen und Institutionen

  • School of Dental Technology, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan.
  • Department of Dentistry, Wan-Fang Hospital, Taipei Medical University, Taipei, Taiwan.
  • Center for Tooth Bank and Dental Stem Cell Technology, Taipei Medical University, Taipei, Taiwan.
  • School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan.
  • Department of Dentistry, Shin Kong Wu Ho-Su Memorial Hospital, Taipei, Taiwan.

Förderung

  • Shin Kong Wu Ho Su Memorial Hospital

Zitieren

APA

Lin, W. C., Lee, C. C., Lee, S. Y., Peng, C. Y., & Lin, C. C. (2025). Influence of operator experience on the complete-arch accuracy and time-based efficiency of three intraoral scanners. Journal of Dental Sciences, 20(1), 620-625. https://doi.org/10.1016/j.jds.2024.11.009

Vancouver

Lin WC, Lee CC, Lee SY, Peng CY, Lin CC. Influence of operator experience on the complete-arch accuracy and time-based efficiency of three intraoral scanners. Journal of Dental Sciences. 2025;20(1):620-625. doi:10.1016/j.jds.2024.11.009

BibTeX
@article{Lin2025,
  author = {Lin, Wei-Chun and Lee, Chian-Chuen and Lee, Sheng-Yang and Peng, Chiao-Yun and Lin, Chia-Cheng},
  title = {Influence of operator experience on the complete-arch accuracy and time-based efficiency of three intraoral scanners},
  journal = {Journal of Dental Sciences},
  year = {2025},
  volume = {20},
  number = {1},
  pages = {620--625},
  doi = {10.1016/j.jds.2024.11.009}
}