EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Trueness and precision of digital light processing fabricated 3D printed monolithic zirconia crowns

Ashraf Refaie, Christoph Bourauel, Tarek Elshazly, Bernd Evers-Dietze, Abdulaziz Alhotan, Mostafa Aldesoki

Journal of Dentistry · 2024

DOI: 10.1016/j.jdent.2024.105151 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Dentistry, 2024. Verfasst von Ashraf Refaie und 5 weiteren Autor:innen. Beteiligte Einrichtung: Oral Technology, Dental School, University Hospital Bonn, Bonn, Germany; Department of Fixed Prosthodontics, Faculty of Dentistry, Fayoum University,…. Hauptthemen laut MEDLINE: Zirconium, Printing, Three-Dimensional, Crowns, Computer-Aided Design. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: The present study aimed to evaluate the trueness and precision of monolithic zirconia crowns (MZCs) fabricated by 3D printing and milling techniques. METHODS: A premolar crown was designed after scanning a prepared typodont. Twenty MZCs were fabricated using milling and 3D-printing techniques (n = 10). All the specimens were scanned with an industrial scanner, and the scanned data were analyzed using 3D measurement software to evaluate the trueness and precision of each group. Root mean square (RMS) deviations were measured and statistically analyzed (One-way ANOVA, Tukey's, p ≤ 0.05). RESULTS: The trueness of the printed MZC group (140 ± 14 μm) showed a significantly higher RMS value compared to the milled MZCs (96 ± 27 μm,p < 0.001). At the same time, the precision of the milled MZCs (61 ± 17 μm) showed a significantly higher RMS value compared to that of the printed MZCs (31 ± 5 μm,p < 0.001). CONCLUSIONS: The Fabrication techniques had a significant impact on the accuracy of the MZCs. Milled MZCs showed the highest trueness, while printed MZCs showed the highest precision. All the results were within the clinically acceptable error values. CLINICAL SIGNIFICANCE: Although the trueness of the milled MZCs is higher, the manufacturing accuracy of the 3D-printed MZCs showed clinically acceptable results in terms of trueness and precision. However, additional clinical studies are recommended. Furthermore, the volumetric changes of the material should be considered.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ZirconiumPrinting, Three-DimensionalCrownsComputer-Aided DesignDental Prosthesis DesignHumansDental MaterialsBicuspidSurface PropertiesMaterials Testing

Stichwörter der Autor:innen

3D printingAccuracyMillingMonolithic zirconia crowns (MZCs)PrecisionTrueness

Substanzen

Zirconiumzirconium oxideDental Materials

Autor:innen und Institutionen

  • Oral Technology, Dental School, University Hospital Bonn, Bonn, Germany; Department of Fixed Prosthodontics, Faculty of Dentistry, Fayoum University, Egypt. Electronic address: ashraf@uni-bonn.de.
  • Oral Technology, Dental School, University Hospital Bonn, Bonn, Germany.
  • Department of Electrical Engineering, Mechanical Engineering and Technical Journalism (EMT), Bonn-Rhein-Sieg University of Applied Sciences, Sankt Augustin, Germany.
  • Department of Dental Health, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia.

Zitieren

APA

Refaie, A., Bourauel, C., Elshazly, T., Evers-Dietze, B., Alhotan, A., & Aldesoki, M. (2024). Trueness and precision of digital light processing fabricated 3D printed monolithic zirconia crowns. Journal of Dentistry. https://doi.org/10.1016/j.jdent.2024.105151

Vancouver

Refaie A, Bourauel C, Elshazly T, Evers-Dietze B, Alhotan A, Aldesoki M. Trueness and precision of digital light processing fabricated 3D printed monolithic zirconia crowns. Journal of Dentistry. 2024. doi:10.1016/j.jdent.2024.105151

BibTeX
@article{Refaie2024,
  author = {Refaie, Ashraf and Bourauel, Christoph and Elshazly, Tarek and Evers-Dietze, Bernd and Alhotan, Abdulaziz and Aldesoki, Mostafa},
  title = {Trueness and precision of digital light processing fabricated 3D printed monolithic zirconia crowns},
  journal = {Journal of Dentistry},
  year = {2024},
  doi = {10.1016/j.jdent.2024.105151}
}
Kostenlos starten →