Clinical performance of two new, fully integrated molecular platforms used for HIV-1, HBV and HCV viral load analysis, the NeuMoDx 288 and the Alinity m.
Journal of Clinical Virology · 2023
DOI: 10.1016/j.jcv.2022.105376 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Virology, 2023. Verfasst von K Mourik und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Microbiology, Leiden University Medical Center, Leiden, The Netherlands. Hauptthemen laut MEDLINE: HIV-1, Hepatitis C, HIV Infections, Hepatitis B. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
BACKGROUND: Viral load (VL) determination in patients with human immunodeficiency virus type 1 (HIV-1), hepatitis B virus (HBV) and hepatitis C virus (HCV) is essential for proper patient management and follow-up. New molecular platforms have been developed to fully automate these diagnostic assays. OBJECTIVE: Evaluation of the clinical performance of HIV-1, HBV and HCV VL assays on the Alinity m (Abbott) and NeuMoDx (Qiagen) molecular platforms. METHOD: Test panels of the three viruses have been compiled of 100 plasma and/or serum samples per target containing non-detectable, non-quantifiable and quantifiable VLs. All samples were retrospectively tested on the Alinity m and NeuMoDx platforms according to manufacturers' instructions. RESULTS: A total of 74, 86 and 66 samples with valid results for both platforms were included in the HIV-1, HBV and HCV analysis respectively. Overall qualitative agreement of the assays on both platforms was 78% for HIV-1, 93% for HBV and 100% for HCV. Quantitative agreement (less than 0.5 log difference) was shown to be 68% for HIV-1, 68% for HBV and 94% for HCV. CONCLUSION: The Alinity m and NeuMoDx HCV assay have a comparable performance. Quantification differences in the HIV-1 assay were mostly apparent in the lower VLs and under-quantification of the NeuMoDx HBV assay was observed.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical Microbiology, Leiden University Medical Center, Leiden, The Netherlands.
- Department of Medical Microbiology, Leiden University Medical Center, Leiden, The Netherlands. Electronic address: E.C.J.Claas@lumc.nl.
Zitieren
APA
Mourik, K., Boers, S. A., van Rijn, A. L., Thijssen, J. C. P., Wessels, E., & Claas, E. C. J. (2023). Clinical performance of two new, fully integrated molecular platforms used for HIV-1, HBV and HCV viral load analysis, the NeuMoDx 288 and the Alinity m. Journal of Clinical Virology. https://doi.org/10.1016/j.jcv.2022.105376
Vancouver
Mourik K, Boers SA, van Rijn AL, Thijssen JCP, Wessels E, Claas ECJ. Clinical performance of two new, fully integrated molecular platforms used for HIV-1, HBV and HCV viral load analysis, the NeuMoDx 288 and the Alinity m. Journal of Clinical Virology. 2023. doi:10.1016/j.jcv.2022.105376
BibTeX
@article{Mourik2023,
author = {Mourik, K and Boers, S A and van Rijn, A L and Thijssen, J C P and Wessels, E and Claas, E C J},
title = {Clinical performance of two new, fully integrated molecular platforms used for HIV-1, HBV and HCV viral load analysis, the NeuMoDx 288 and the Alinity m},
journal = {Journal of Clinical Virology},
year = {2023},
doi = {10.1016/j.jcv.2022.105376}
}
EUVIMED