Minimally invasive hardware-free supracondylar femoral osteotomy for genu valgum correction: A retrospective study
Journal of Clinical Orthopaedics and Trauma · 2026-05 · 76 · 103402
DOI: 10.1016/j.jcot.2026.103402 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Orthopaedics and Trauma, 2026-05. Verfasst von Vikram A Mhaskar und 3 weiteren Autor:innen. Beteiligte Einrichtung: JMVM Sports Injury Centre, Sitaram Bhartia Institute Of Science & Research, New Delhi, India. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Traditional methods for surgical correction of symptomatic genu valgum require extensive exposure, implants, and drilling. These factors increase morbidity, cost, and complication rates. This study aimed to evaluate the functional and radiological outcomes of a minimally invasive hardware-free supracondylar femoral osteotomy for genu valgum correction in adolescents and young adults.
Methods
A retrospective review of patients undergoing minimally invasive osteotomy for symptomatic genu valgum between October 2020 and August 2023. The implant-less technique involved a 1-cm stab incision, internal weakening of the cortices with an osteotome, and controlled varus force to achieve correction, followed by long leg, ankle-sparing cylinder casting. Radiological outcomes were assessed using Mechanical Axis Deviation Angle (MAD-A), while clinical outcomes were measured using Knee Injury and Osteoarthritis Outcome Score (KOOS) and Böstman scores. Statistical analysis was performed using paired t-tests or Wilcoxon signed-rank test.
Results
The study included 47 knees from 27 patients (24 females, 3 males) with a mean age of 15.3 ± 2.9 years (range, 11-25 years) and a follow-up period of 41.4 ± 24.6 months. The mean MAD-A improved significantly from 5.3° ± 2.1 (right) and 4.9° ± 2.4 (left) to -0.3° ± 0.6 and -0.5° ± 0.9, respectively (p < 0.001). KOOS scores improved modestly (88.9 ± 3.3 preoperatively to 89.9 ± 6.5 at final follow-up, p = 0.465), while Böstman scores increased significantly from 22.5 ± 1.8 at 6 weeks posteroperatively to 27.9 ± 2.2 at final follow-up (p < 0.001). One knee required supplemental fixation with a single Kirschner-wire. All patients achieved radiographic union by 6 weeks postoperatively.
Conclusion
This minimally invasive hardware-free supracondylar femoral osteotomy achieves effective and stable deformity correction with excellent functional and radiological outcomes. It eliminates growth plate disruption and implant-related complications, offering a reliable, cost-efficient alternative, particularly suitable for resource-limited or low-compliance settings. Level of evidence IV, therapeutic case series.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- JMVM Sports Injury Centre, Sitaram Bhartia Institute Of Science & Research, New Delhi, India.
- Vardhman Mahavir Medical College and Safdarjung Hospital, New Delhi, India.
Zitieren
APA
Mhaskar, V. A., Saggar, R., Maheshwari, J., & Patel, H. (2026). Minimally invasive hardware-free supracondylar femoral osteotomy for genu valgum correction: A retrospective study. Journal of Clinical Orthopaedics and Trauma, 76, 103402. https://doi.org/10.1016/j.jcot.2026.103402
Vancouver
Mhaskar VA, Saggar R, Maheshwari J, Patel H. Minimally invasive hardware-free supracondylar femoral osteotomy for genu valgum correction: A retrospective study. Journal of Clinical Orthopaedics and Trauma. 2026;76:103402. doi:10.1016/j.jcot.2026.103402
BibTeX
@article{Mhaskar2026,
author = {Mhaskar, Vikram A and Saggar, Rachit and Maheshwari, Jitendra and Patel, Het},
title = {Minimally invasive hardware-free supracondylar femoral osteotomy for genu valgum correction: A retrospective study},
journal = {Journal of Clinical Orthopaedics and Trauma},
year = {2026},
volume = {76},
pages = {103402},
doi = {10.1016/j.jcot.2026.103402}
}
EUVIMED