Vadose-zone control of PFOS delivery to groundwater: Explicit unsaturated-zone transport with solid-phase and air–water interfacial sorption
Journal of Contaminant Hydrology · 2027-01 · 284 · 105141
DOI: 10.1016/j.jconhyd.2026.105141 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Contaminant Hydrology, 2027-01. Verfasst von Vahid Rafiei. Beteiligte Einrichtung: Independent Researcher. Electronic address: vahidr32@gmail.com. Die Arbeit nennt 29 Literaturangaben.
Abstract (Originalsprache)
Quantifying PFOS retention in the unsaturated zone beneath contaminated sites requires a model that simulates how much PFOS the unsaturated zone holds and when PFOS first reaches groundwater. Both determine how long a source keeps feeding the aquifer and when watershed and site assessments need an explicit unsaturated zone. We modified the unsaturated-zone transport of MODFLOW 6 to simulate solid-phase and air-water interfacial sorption, each dependent on water content, and drove it at two sites with daily percolation from SWAT+. We applied it at three sites that differ in depth to water, infiltration and water content: two firefighting-foam sites and a tannery legacy source. At the shallow site, the same released mass was run once through the unsaturated zone and once directly to the water table. In a simulated 6.4-6.9 m column (3.0-4.3 m measured nearby), 63-83% of the PFOS released in 1971-1994 was above the water table in 2024, and its median crossing was delayed by at least 42 years; PFOS in the deep aquifer was 70-83% lower in 2017. Without sorption the two runs agreed within 0.2%, so the delay is sorption, not water movement. An advection-dispersion screen shows that 1/10,000 of the source concentration first reaches the water table within a median of 18-38 years at a dispersivity of 10% of the depth, against a median transit of 83-182 years. A single travel time answers neither question: a screen must report when PFOS is first detected and how long the unsaturated zone feeds the aquifer.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Independent Researcher. Electronic address: vahidr32@gmail.com.
Zitieren
APA
Rafiei, V. (2027). Vadose-zone control of PFOS delivery to groundwater: Explicit unsaturated-zone transport with solid-phase and air–water interfacial sorption. Journal of Contaminant Hydrology, 284, 105141. https://doi.org/10.1016/j.jconhyd.2026.105141
Vancouver
Rafiei V. Vadose-zone control of PFOS delivery to groundwater: Explicit unsaturated-zone transport with solid-phase and air–water interfacial sorption. Journal of Contaminant Hydrology. 2027;284:105141. doi:10.1016/j.jconhyd.2026.105141
BibTeX
@article{Rafiei2027,
author = {Rafiei, Vahid},
title = {Vadose-zone control of PFOS delivery to groundwater: Explicit unsaturated-zone transport with solid-phase and air–water interfacial sorption},
journal = {Journal of Contaminant Hydrology},
year = {2027},
volume = {284},
pages = {105141},
doi = {10.1016/j.jconhyd.2026.105141}
}
EUVIMED