EUVIMEDEUVIMED entdecken
Crossref

Electrode noise for induced polarization measurements: Insights of contaminant interference

Deqiang Mao, Jian Meng, Alex Furman, Jiaming Zhang, Shupeng Li, Ruijue Zhao, Yaxun Wang

Journal of Contaminant Hydrology · 2027-01 · 284 · 105115

DOI: 10.1016/j.jconhyd.2026.105115 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Contaminant Hydrology, 2027-01. Verfasst von Deqiang Mao und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Civil Engineering, Shandong University, Jinan 250061, China. Electronic address: maodeqiang@sdu.edu.cn. Die Arbeit nennt 73 Literaturangaben. Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The induced polarization (IP) method has significant potential for characterizing and monitoring groundwater contamination, particularly given recent advances in extracting rich spectral information from time domain IP (TDIP) data. However, its effectiveness depends on the quality of full-waveform data, and the impact of electrode noise remains insufficiently understood in field applications, especially at contaminated sites. Sandbox experiments were designed to evaluate electrode durability and IP data errors under field relevant combinations of contaminant type and conductivity at sampling rates of 0.1, 10, and 10,000 Hz. An error assessment method combining probability distributions, Fourier transforms, and the signal to noise ratio was proposed. It reveals the frequency ranges of amplitude and phase spectral information inherent in TD data. Pb-PbCl2 electrodes remained stable across the contaminant and conductivity range. For stainless steel electrodes, low-frequency noise decreased with increasing conductivity. Differences among contaminated media at same target conductivity are interpreted as combined responses to conductivity and ionic composition rather than as isolated contaminant effects. Organic contaminants may cause anomalous trends in electrode noise. Amplitude spectra were reliable across most of the 0.001-1000 Hz range, but for weaker signal, the SNR of stainless steel electrodes fell below 10 dB at

Schlagwörter

Stichwörter der Autor:innen

Contaminant interferenceElectrodeInduced polarizationSignal to noise ratioSoil and groundwater contamination

Autor:innen und Institutionen

  • School of Civil Engineering, Shandong University, Jinan 250061, China. Electronic address: maodeqiang@sdu.edu.cn.
  • School of Civil Engineering, Shandong University, Jinan 250061, China. Electronic address: mengjiansdu@163.com.
  • Civil and Environmental Engineering, Technion, Israel Institute of Technology, Haifa, Israel.
  • National Engineering Laboratory for Site Remediation Technologies, Beijing Construction Engineering Group Environmental Remediation Co., Ltd, Beijing, China.
  • School of Civil Engineering, Shandong University, Jinan 250061, China.

Förderung

  • National Key Research and Development Program of China
  • National Natural Science Foundation of China

Zitieren

APA

Mao, D., Meng, J., Furman, A., Zhang, J., Li, S., Zhao, R., & Wang, Y. (2027). Electrode noise for induced polarization measurements: Insights of contaminant interference. Journal of Contaminant Hydrology, 284, 105115. https://doi.org/10.1016/j.jconhyd.2026.105115

Vancouver

Mao D, Meng J, Furman A, Zhang J, Li S, Zhao R, et al. Electrode noise for induced polarization measurements: Insights of contaminant interference. Journal of Contaminant Hydrology. 2027;284:105115. doi:10.1016/j.jconhyd.2026.105115

BibTeX
@article{Mao2027,
  author = {Mao, Deqiang and Meng, Jian and Furman, Alex and Zhang, Jiaming and Li, Shupeng and Zhao, Ruijue and Wang, Yaxun},
  title = {Electrode noise for induced polarization measurements: Insights of contaminant interference},
  journal = {Journal of Contaminant Hydrology},
  year = {2027},
  volume = {284},
  pages = {105115},
  doi = {10.1016/j.jconhyd.2026.105115}
}