Temperature effects for tetrachloroethylene removal with NZVI between 10 and 55 °C in flow-through column experiments
Journal of Contaminant Hydrology · 2025
DOI: 10.1016/j.jconhyd.2025.104565 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Contaminant Hydrology, 2025. Verfasst von Alexander Schwardt und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Applied Geology, Aquatic Geochemistry and Hydrogeology, Institute of Geoscience, Kiel University, 24118 Kiel, Germany. Electronic addre…. Hauptthemen laut MEDLINE: Tetrachloroethylene, Water Pollutants, Chemical, Iron, Environmental Restoration and Remediation. Die Arbeit nennt 82 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Bundesministerium für Wirtschaft und Energie, Bundesministerium für Wirtschaft und Klimaschutz.
Abstract (Originalsprache)
Subsurface utilization for underground thermal energy storage (UTES) in urban areas can promote a sustainable and climate-neutral heat supply. Meanwhile, frequent subsoil contamination raises the question of whether the stored heat could be used for remediation, which can benefit from increased temperatures (e.g., by increased reactivity and desorption processes or enhanced microbial degradation). We focus on nanoscale zerovalent iron (NZVI), which is suitable for chlorinated hydrocarbon remediation. However, the potential benefits or drawbacks of increased temperatures for groundwater remediation, including accelerated contaminant degradation, declining long-term reactivity, or influenced passivation processes by mineral precipitation, remain largely unexplored. Herein, we investigate the effect of temperature changes (10-55 °C) on NZVI's long-term degradation of tetrachloroethylene (PCE) using column experiments to assess the approach's suitability for coupling with UTES. Using demineralized water (DW), maximum PCE removal rates (kPCE) between 10 and 55 °C increased from 0.13 to 2.3 h-1. With tap water (TW), kPCE increased between 10 and 40 °C from 0.18 to 0.75 h-1. Due to the higher PCE removal rates in combination with increasing H2 generation caused by enhanced anaerobic corrosion, long-term corrosion reactivity decreased between 10 and 55 °C from ∼275 to 14 d with DW and from 150 to 30 d between 10 and 40 °C with TW, whereby the increased H2 formation is beneficial for microbial degradation. Accelerated passivation of the NZVI due to carbonate precipitation was not observed for the examined temperatures. Therefore, the experiments revealed that combining UTES with NZVI for remediation purposes is practicable, offering clear remediation advantages.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Applied Geology, Aquatic Geochemistry and Hydrogeology, Institute of Geoscience, Kiel University, 24118 Kiel, Germany. Electronic address: alexander.schwardt@ifg.uni-kiel.de.
- Department of Applied Geology, Aquatic Geochemistry and Hydrogeology, Institute of Geoscience, Kiel University, 24118 Kiel, Germany.
Förderung
- Bundesministerium für Wirtschaft und Energie
- Bundesministerium für Wirtschaft und Klimaschutz
Zitieren
APA
Schwardt, A., Popp, N. F., Dahmke, A., & Köber, R. (2025). Temperature effects for tetrachloroethylene removal with NZVI between 10 and 55 °C in flow-through column experiments. Journal of Contaminant Hydrology. https://doi.org/10.1016/j.jconhyd.2025.104565
Vancouver
Schwardt A, Popp NF, Dahmke A, Köber R. Temperature effects for tetrachloroethylene removal with NZVI between 10 and 55 °C in flow-through column experiments. Journal of Contaminant Hydrology. 2025. doi:10.1016/j.jconhyd.2025.104565
BibTeX
@article{Schwardt2025,
author = {Schwardt, Alexander and Popp, Nils Fridtjof and Dahmke, Andreas and Köber, Ralf},
title = {Temperature effects for tetrachloroethylene removal with NZVI between 10 and 55 °C in flow-through column experiments},
journal = {Journal of Contaminant Hydrology},
year = {2025},
doi = {10.1016/j.jconhyd.2025.104565}
}
EUVIMED