Multizentrische Studie in der Zeitschrift Journal of Cranio-Maxillofacial Surgery, 2026-09. Verfasst von Sorana Eftimie und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Maxillofacial Surgery and Radiology, Iuliu Hațieganu University of Medicine and Pharmacy, Cluj-Napoca, 400347, Romania. Hauptthemen laut MEDLINE: Orbital Fractures, Workflow, Artificial Intelligence, Plastic Surgery Procedures. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Commission.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Orbital reconstruction after trauma or pathology requires precise restoration of anatomical symmetry to prevent functional and aesthetic impairment. Although virtual surgical planning and computer-aided design/manufacturing have significantly improved workflows, segmentation and mirroring of the orbit remain primarily manual and operator-dependent. This study developed and validated a fully automated, AI-based workflow that integrates deep learning-driven segmentation and algorithmic mirroring for improved efficiency and reproducibility in orbital reconstruction. A multicenter dataset comprising 502 cranial CT scans from Germany, Romania, and the USA was employed to train and evaluate a full-resolution 3D nnU-Net model for automated orbital segmentation. Following segmentation, a mirroring algorithm using Principal Component Analysis and Iterative Closest Point registration computed the sagittal symmetry plane. Automated outcomes were benchmarked against manual segmentation and mirroring by clinical experts, using metrics including Dice Similarity Coefficient, Mean Surface Distance, Hausdorff Distance, and angular deviation between symmetry planes. The AI-driven segmentation achieved high accuracy (mean DSC 0.936), with superior performance in non-fractured orbits (DSC up to 0.941). Angular deviation from manually defined symmetry planes was minimal (fractured: 0.95° ± 0.65°; non-fractured: 0.72° ± 0.53°), consistent across institutions. This automated approach demonstrated robust, clinically applicable segmentation and mirroring accuracy, enabling standardized and efficient orbital reconstruction workflows.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Orbital FracturesWorkflowArtificial IntelligencePlastic Surgery ProceduresHumansTomography, X-Ray ComputedAlgorithmsImaging, Three-DimensionalDeep LearningReproducibility of ResultsOrbitImage Processing, Computer-Assisted

Stichwörter der Autor:innen

Artificial intelligenceComputer simulationImage processingOrbital fracturesVirtual surgical planning

Autor:innen und Institutionen

  • Department of Maxillofacial Surgery and Radiology, Iuliu Hațieganu University of Medicine and Pharmacy, Cluj-Napoca, 400347, Romania.
  • Department of Oral and Cranio-Maxillofacial Surgery and 3D Print Lab, University Hospital Basel, Basel, Switzerland; Medical Additive Manufacturing Research Group (Swiss MAM), Department of Biomedical Engineering, Unive…
  • Department of Oral and Maxillofacial Surgery, University Hospital RWTH Aachen, Aachen, 52074, Germany.
  • Department of Oral and Maxillofacial Surgery, University Hospital RWTH Aachen, Aachen, 52074, Germany; Institute of Medical Informatics, University Hospital RWTH Aachen, Aachen, 52074, Germany.
  • Department of Oral and Maxillofacial Surgery, Lucerne Cantonal Hospital, Spitalstrasse, Lucerne, 6000, Switzerland.

Förderung

  • European Commission

Zitieren

APA

Eftimie, S., Beyer, M., Rashad, A., Vladu, O., Puladi, B., Hölzle, F., Thieringer, F. M., Gander, T., & Ilesan, R. R. (2026). Fully automated AI-based digital workflow for orbital fracture mirroring: A multicenter approach. Journal of Cranio-Maxillofacial Surgery, 54(9), 104637. https://doi.org/10.1016/j.jcms.2026.104637

Vancouver

Eftimie S, Beyer M, Rashad A, Vladu O, Puladi B, Hölzle F, et al. Fully automated AI-based digital workflow for orbital fracture mirroring: A multicenter approach. Journal of Cranio-Maxillofacial Surgery. 2026;54(9):104637. doi:10.1016/j.jcms.2026.104637

BibTeX
@article{Eftimie2026,
  author = {Eftimie, Sorana and Beyer, Michel and Rashad, Ashkan and Vladu, Oliver and Puladi, Behrus and Hölzle, Frank and Thieringer, Florian M and Gander, Thomas and Ilesan, Robert R},
  title = {Fully automated AI-based digital workflow for orbital fracture mirroring: A multicenter approach},
  journal = {Journal of Cranio-Maxillofacial Surgery},
  year = {2026},
  volume = {54},
  number = {9},
  pages = {104637},
  doi = {10.1016/j.jcms.2026.104637}
}
Kostenlos starten →