EUVIMEDEUVIMED entdecken
Vergleichsstudie

Why detailed modeling matters in the FE-based pre-clinical evaluation of temporomandibular joint implants

Girish Chandra, Rajdeep Ghosh, Vivek Verma, Kamalpreet Kaur, Ajoy Roychoudhury, Sudipto Mukherjee, Anoop Chawla, Kaushik Mukherjee

Journal of Cranio-Maxillofacial Surgery · 2026-08 · 54 (8) · 104595

DOI: 10.1016/j.jcms.2026.104595 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Cranio-Maxillofacial Surgery, 2026-08. Verfasst von Girish Chandra und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Indian Institute of Technology Delhi, New Delhi, Delhi, India. Hauptthemen laut MEDLINE: Finite Element Analysis, Temporomandibular Joint, Joint Prosthesis, Models, Biological. Die Arbeit nennt 38 Literaturangaben. Gefördert von: Indian Institute of Technology Delhi, Indo-German Science and Technology Centre.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

End-stage temporomandibular joint (TMJ) disorders often necessitate joint replacement to restore bilateral mastication. Patient-specific TMJ implants typically rely on detailed in silico modeling derived from subject-specific computed tomography (CT) scans of the mandible. However, generating highly detailed finite element (FE) models is computationally expensive. Although structural simplifications of the mandible are known to influence mechanical behavior, their quantitative impact on TMJ implant evaluation has not been systematically investigated. Our study examined the influence of three modeling simplifications on stress-strain predictions in intact and implanted mandibles: (i) a detailed segmented mandible with tissue-specific material properties (Model 1); (ii) a simplified mandible comprising cortical bone only (Model 2); and (iii) a further simplified mandible excluding dental crowns (Model 3). Both narrow and standard TMJ implants were analyzed under osseointegrated and non-osseointegrated conditions, resulting in 15 FE models. Physiological clenching activities were simulated. Compared with the detailed model, simplified models showed reductions of up to 50% in maximum principal strain in bone and up to 44% in von Mises stress in TMJ implants, while preserving spatial stress-strain trends. These findings indicate that simplified models may be suitable for preliminary implant design, whereas detailed FE modeling remains essential for final preclinical evaluation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Finite Element AnalysisTemporomandibular JointJoint ProsthesisModels, BiologicalHumansMandibleBiomechanical PhenomenaComputer SimulationStress, MechanicalBite ForceOsseointegrationCortical BoneModels, AnatomicImaging, Three-DimensionalMandibular CondyleProsthesis DesignTemporal MuscleMasseter Muscle

Stichwörter der Autor:innen

Biomet stock TMJFE analysisMandibleMandibular implantMastication cycle

Autor:innen und Institutionen

  • Department of Mechanical Engineering, Indian Institute of Technology Delhi, New Delhi, Delhi, India.
  • Department of Mechanical Engineering, Indian Institute of Technology Delhi, New Delhi, Delhi, India; Department of Mechanical Engineering, National Institute of Technology Agartala, Jirania, Tripura, India.
  • Department of Mechanical Engineering, Indian Institute of Technology Delhi, New Delhi, Delhi, India; Department of Mechanical Engineering, Indian Institute of Technology Patna, Patna, Bihar, India.
  • Department of Oral and Maxillofacial Surgery, CDER, All India Institute of Medical Sciences, New Delhi, Delhi, India.
  • Department of Mechanical Engineering, Indian Institute of Technology Delhi, New Delhi, Delhi, India. Electronic address: kmukherjee@mech.iitd.ac.in.

Förderung

  • Indian Institute of Technology Delhi
  • Indo-German Science and Technology Centre

Zitieren

APA

Chandra, G., Ghosh, R., Verma, V., Kaur, K., Roychoudhury, A., Mukherjee, S., Chawla, A., & Mukherjee, K. (2026). Why detailed modeling matters in the FE-based pre-clinical evaluation of temporomandibular joint implants. Journal of Cranio-Maxillofacial Surgery, 54(8), 104595. https://doi.org/10.1016/j.jcms.2026.104595

Vancouver

Chandra G, Ghosh R, Verma V, Kaur K, Roychoudhury A, Mukherjee S, et al. Why detailed modeling matters in the FE-based pre-clinical evaluation of temporomandibular joint implants. Journal of Cranio-Maxillofacial Surgery. 2026;54(8):104595. doi:10.1016/j.jcms.2026.104595

BibTeX
@article{Chandra2026,
  author = {Chandra, Girish and Ghosh, Rajdeep and Verma, Vivek and Kaur, Kamalpreet and Roychoudhury, Ajoy and Mukherjee, Sudipto and Chawla, Anoop and Mukherjee, Kaushik},
  title = {Why detailed modeling matters in the FE-based pre-clinical evaluation of temporomandibular joint implants},
  journal = {Journal of Cranio-Maxillofacial Surgery},
  year = {2026},
  volume = {54},
  number = {8},
  pages = {104595},
  doi = {10.1016/j.jcms.2026.104595}
}
Kostenlos starten →