Why detailed modeling matters in the FE-based pre-clinical evaluation of temporomandibular joint implants
Journal of Cranio-Maxillofacial Surgery · 2026-08 · 54 (8) · 104595
DOI: 10.1016/j.jcms.2026.104595 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Cranio-Maxillofacial Surgery, 2026-08. Verfasst von Girish Chandra und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Indian Institute of Technology Delhi, New Delhi, Delhi, India. Hauptthemen laut MEDLINE: Finite Element Analysis, Temporomandibular Joint, Joint Prosthesis, Models, Biological. Die Arbeit nennt 38 Literaturangaben. Gefördert von: Indian Institute of Technology Delhi, Indo-German Science and Technology Centre.
Abstract (Originalsprache)
End-stage temporomandibular joint (TMJ) disorders often necessitate joint replacement to restore bilateral mastication. Patient-specific TMJ implants typically rely on detailed in silico modeling derived from subject-specific computed tomography (CT) scans of the mandible. However, generating highly detailed finite element (FE) models is computationally expensive. Although structural simplifications of the mandible are known to influence mechanical behavior, their quantitative impact on TMJ implant evaluation has not been systematically investigated. Our study examined the influence of three modeling simplifications on stress-strain predictions in intact and implanted mandibles: (i) a detailed segmented mandible with tissue-specific material properties (Model 1); (ii) a simplified mandible comprising cortical bone only (Model 2); and (iii) a further simplified mandible excluding dental crowns (Model 3). Both narrow and standard TMJ implants were analyzed under osseointegrated and non-osseointegrated conditions, resulting in 15 FE models. Physiological clenching activities were simulated. Compared with the detailed model, simplified models showed reductions of up to 50% in maximum principal strain in bone and up to 44% in von Mises stress in TMJ implants, while preserving spatial stress-strain trends. These findings indicate that simplified models may be suitable for preliminary implant design, whereas detailed FE modeling remains essential for final preclinical evaluation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mechanical Engineering, Indian Institute of Technology Delhi, New Delhi, Delhi, India.
- Department of Mechanical Engineering, Indian Institute of Technology Delhi, New Delhi, Delhi, India; Department of Mechanical Engineering, National Institute of Technology Agartala, Jirania, Tripura, India.
- Department of Mechanical Engineering, Indian Institute of Technology Delhi, New Delhi, Delhi, India; Department of Mechanical Engineering, Indian Institute of Technology Patna, Patna, Bihar, India.
- Department of Oral and Maxillofacial Surgery, CDER, All India Institute of Medical Sciences, New Delhi, Delhi, India.
- Department of Mechanical Engineering, Indian Institute of Technology Delhi, New Delhi, Delhi, India. Electronic address: kmukherjee@mech.iitd.ac.in.
Förderung
- Indian Institute of Technology Delhi
- Indo-German Science and Technology Centre
Zitieren
APA
Chandra, G., Ghosh, R., Verma, V., Kaur, K., Roychoudhury, A., Mukherjee, S., Chawla, A., & Mukherjee, K. (2026). Why detailed modeling matters in the FE-based pre-clinical evaluation of temporomandibular joint implants. Journal of Cranio-Maxillofacial Surgery, 54(8), 104595. https://doi.org/10.1016/j.jcms.2026.104595
Vancouver
Chandra G, Ghosh R, Verma V, Kaur K, Roychoudhury A, Mukherjee S, et al. Why detailed modeling matters in the FE-based pre-clinical evaluation of temporomandibular joint implants. Journal of Cranio-Maxillofacial Surgery. 2026;54(8):104595. doi:10.1016/j.jcms.2026.104595
BibTeX
@article{Chandra2026,
author = {Chandra, Girish and Ghosh, Rajdeep and Verma, Vivek and Kaur, Kamalpreet and Roychoudhury, Ajoy and Mukherjee, Sudipto and Chawla, Anoop and Mukherjee, Kaushik},
title = {Why detailed modeling matters in the FE-based pre-clinical evaluation of temporomandibular joint implants},
journal = {Journal of Cranio-Maxillofacial Surgery},
year = {2026},
volume = {54},
number = {8},
pages = {104595},
doi = {10.1016/j.jcms.2026.104595}
}