EUVIMEDEUVIMED entdecken
Crossref

Patient-specific implants in minimally invasive orthognathic surgery: A case series

Matheus Spinella Almeida, Hugo Jose Correia Lopes, Lucas Viana Silva Ramos, Otacilio Chagas Junior, Jonathas Daniel Paggi Claus

Journal of Cranio-Maxillofacial Surgery · 2026-07 · 54 (7) · 104575

DOI: 10.1016/j.jcms.2026.104575 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cranio-Maxillofacial Surgery, 2026-07. Verfasst von Matheus Spinella Almeida und 4 weiteren Autor:innen. Beteiligte Einrichtung: Instituto Bucomaxilofacial, Florianópolis, SC, Brazil. Hauptthemen laut MEDLINE: Minimally Invasive Surgical Procedures, Orthognathic Surgical Procedures, Dental Implants. Die Arbeit nennt 14 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aimed to evaluate the accuracy of maxillary repositioning using patient-specific implants (PSI) adapted for minimally invasive orthognathic surgery (MIOS), employing a simplified two-plate fixation protocol. Although all patients underwent bimaxillary orthognathic surgery, quantitative accuracy analysis was limited to the maxilla. This retrospective study included 20 patients treated with PSI tailored for MIOS. The surgical protocol involved limited soft tissue dissection and maxillary fixation using only two plates. Postoperative accuracy was assessed through computed tomography and voxel-based comparison with the virtual surgical plan. Discrepancies were measured in three linear axes and cant correction. Statistical analysis included Bland-Altman plots, effect sizes, and intraclass correlation coefficients (ICCs). All procedures were completed without intraoperative complications. Discrepancies between planned and postoperative positions ranged from 0.02 mm to 0.31 mm. ICCs exceeded 0.82 across all variables, with cant correction ICCs of 0.98 and 0.99. Effect sizes were negligible to small, and Bland-Altman analysis revealed no systematic bias. Customized PSI can be effectively adapted for use in MIOS protocols. Despite a reduced fixation strategy, high accuracy and reproducibility were achieved. These findings support the use of simplified PSI workflows as a precise and less invasive alternative in modern orthognathic surgery.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Minimally Invasive Surgical ProceduresOrthognathic Surgical ProceduresDental ImplantsHumansDental ImplantationRetrospective StudiesMaxillaTomography, X-Ray ComputedMaleFemaleYoung AdultAdultImaging, Three-DimensionalSurgery, Computer-Assisted

Stichwörter der Autor:innen

Minimally invasive surgical proceduresOrthognathic surgeryPATIENT-specific modelingThree-dimensional imaging

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Instituto Bucomaxilofacial, Florianópolis, SC, Brazil.
  • Universidade Federal de Pelotas, RS, Brazil.
  • Instituto Bucomaxilofacial, Florianópolis, SC, Brazil. Electronic address: cirurgiaofacial@gmail.com.

Zitieren

APA

Almeida, M. S., Lopes, H. J. C., Ramos, L. V. S., Junior, O. C., & Claus, J. D. P. (2026). Patient-specific implants in minimally invasive orthognathic surgery: A case series. Journal of Cranio-Maxillofacial Surgery, 54(7), 104575. https://doi.org/10.1016/j.jcms.2026.104575

Vancouver

Almeida MS, Lopes HJC, Ramos LVS, Junior OC, Claus JDP. Patient-specific implants in minimally invasive orthognathic surgery: A case series. Journal of Cranio-Maxillofacial Surgery. 2026;54(7):104575. doi:10.1016/j.jcms.2026.104575

BibTeX
@article{Almeida2026,
  author = {Almeida, Matheus Spinella and Lopes, Hugo Jose Correia and Ramos, Lucas Viana Silva and Junior, Otacilio Chagas and Claus, Jonathas Daniel Paggi},
  title = {Patient-specific implants in minimally invasive orthognathic surgery: A case series},
  journal = {Journal of Cranio-Maxillofacial Surgery},
  year = {2026},
  volume = {54},
  number = {7},
  pages = {104575},
  doi = {10.1016/j.jcms.2026.104575}
}
Kostenlos starten →