A three – dimensional assessment of the accuracy of lefort 1 osteotomy using patient specific implants

Onur Koç, Hakan Hıfzı Tüz

Journal of Cranio-Maxillofacial Surgery · 2025

DOI: 10.1016/j.jcms.2025.07.016 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cranio-Maxillofacial Surgery, 2025. Verfasst von Onur Koç und 1 weiteren Autor:innen. Beteiligte Einrichtung: Hacettepe University, Faculty of Dentistry, Department of Oral and Maxillofacial Surgery, Ankara, Turkey. Electronic address: onurkoc101@gmail.com. Hauptthemen laut MEDLINE: Osteotomy, Le Fort, Imaging, Three-Dimensional, Dental Implants, Surgery, Computer-Assisted. Die Arbeit nennt 40 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study evaluated patient specific implant (PSI) accuracy at different maxillary locations during LeFort 1 osteotomy. Twelve patients underwent LeFort 1 osteotomy using PSIs and surgical guides. Deviations between the planned and actual positions were calculated for point A, mid-upper-incisal point, canine cusps, and first molar mesiobuccal cusps across the three axes. Spearman's Rho, Friedman, and Wilcoxon Tests with Bonferroni correction were used for analyses. Maxillary movements in LeFort 1 surgery averaged 1,46 ± 0,09 mm mediolaterally, 3,75 ± 0,23 mm anteroposteriorly, and 1,08 ± 0,17 mm superoinferiorly. The average amounts of deviations were 0,41 ± 0,03 mm (mediolateral), 0,60 ± 0,14 mm (anteroposterior), and 0,45 ± 0,15 mm (superoinferior). Negative correlations existed between planned movement and deviation at point A (superoinferior, P = 0.022) and left first molar (mediolateral, P = 0.045). Posterior teeth showed higher deviations (0.62 ± 0.42 mm) than anterior teeth (0.34 ± 0.30 mm) in the superoinferior direction (P = 0.007). The PSI technique ensures excellent transfer of the desired vertical position of the anterior teeth. Small anterior vertical and posterior transverse movements are more prone to deviations than great movements in the same regions and axes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Osteotomy, Le FortImaging, Three-DimensionalDental ImplantsSurgery, Computer-AssistedHumansMaleFemaleMaxillaAdultPatient Care PlanningYoung AdultAdolescent

Stichwörter der Autor:innen

AccuracyDeviation analysisDimensional assessmentLeFort 1 osteotomyPatient-specific implantsSurgical guidesThree

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Hacettepe University, Faculty of Dentistry, Department of Oral and Maxillofacial Surgery, Ankara, Turkey. Electronic address: onurkoc101@gmail.com.
  • Hacettepe University, Faculty of Dentistry, Department of Oral and Maxillofacial Surgery, Ankara, Turkey.

Zitieren

APA

Koç, O., & Tüz, H. H. (2025). A three – dimensional assessment of the accuracy of lefort 1 osteotomy using patient specific implants. Journal of Cranio-Maxillofacial Surgery. https://doi.org/10.1016/j.jcms.2025.07.016

Vancouver

Koç O, Tüz HH. A three – dimensional assessment of the accuracy of lefort 1 osteotomy using patient specific implants. Journal of Cranio-Maxillofacial Surgery. 2025. doi:10.1016/j.jcms.2025.07.016

BibTeX
@article{Ko2025,
  author = {Koç, Onur and Tüz, Hakan Hıfzı},
  title = {A three – dimensional assessment of the accuracy of lefort 1 osteotomy using patient specific implants},
  journal = {Journal of Cranio-Maxillofacial Surgery},
  year = {2025},
  doi = {10.1016/j.jcms.2025.07.016}
}
Kostenlos starten →