EUVIMEDEUVIMED entdecken
Crossref

Customized orbital implant versus 3D preformed titanium mesh for orbital fracture repair: A retrospective comparative analysis of orbital reconstruction accuracy

Giuseppe Consorti, Enrico Betti, Lisa Catarzi

Journal of Cranio-Maxillofacial Surgery · 2024

DOI: 10.1016/j.jcms.2024.02.012 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cranio-Maxillofacial Surgery, 2024. Verfasst von Giuseppe Consorti und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Maxillofacial Surgery, Azienda Ospedaliera Universitaria, Ospedali Riuniti di Ancona, Umberto, Italy. Electronic address: giuseppe.cons…. Hauptthemen laut MEDLINE: Orbital Fractures, Orbital Implants, Dental Implants, Enophthalmos. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 19 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aimed to compare the accuracy of inferomedial orbital fracture restoration using customized orbital implant versus 3D preformed titanium mesh. Patients were divided into two groups. Group 1 underwent surgery with customized orbital implants and intraoperative navigation, while group 2 was treated using 3D preformed titanium meshes with preoperative virtual surgical planning (VSP) and intraoperative navigation. Reconstruction accuracy was assessed by: (1) comparing the postoperative reconstruction mesh position with the preoperative VSP; and (2) measuring the difference between the reconstructed and unaffected orbital volume. Pre- and postoperative diplopia and enophthalmos were also evaluated. Fifty-two patients were enrolled (25 in group 1 vs 27 in group 2). The mean difference between final plate position and ideal digital plan was 0.62 mm (SD = 0.235) in group 1 and 0.69 mm (SD = 0.246) in group 2, with no statistical difference between the groups (p = 0.282). The mean volume differences between the reconstructed and unaffected orbits were 0.95 ml and 1.02 ml in group 1 and group 2, respectively, with no significant difference between the groups (p = 0.860). Overall clinical improvements, as well as complications, were similar. 3D preformed titanium meshes can reconstruct inferomedial fractures with the same accuracy as customized implants. Therefore, in clinical practice, it is recommended to use 3D preformed meshes for this type of fracture due to their excellent results and the potential for reducing time and costs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Orbital FracturesOrbital ImplantsDental ImplantsEnophthalmosHumansTitaniumRetrospective StudiesSurgical MeshOrbit

Stichwörter der Autor:innen

Blow-out fractureComputer-assisted surgeryCustomized orbital implantIntraoperative navigationOrbital fracturePreformed titanium mesh

Substanzen

TitaniumDental Implants

Autor:innen und Institutionen

  • Department of Maxillofacial Surgery, Azienda Ospedaliera Universitaria, Ospedali Riuniti di Ancona, Umberto, Italy. Electronic address: giuseppe.consorti@ospedaliriuniti.marche.it.
  • Department of Maxillofacial Surgery, Azienda Ospedaliera Universitaria, Ospedali Riuniti di Ancona, Umberto, Italy.
  • Department of Maxillofacial Surgery, Azienda Ospedaliera Universitaria, Ospedali Riuniti di Ancona, Umberto, Italy; Department of Maxillofacial Surgery, University of Siena, Siena, Italy.

Zitieren

APA

Consorti, G., Betti, E., & Catarzi, L. (2024). Customized orbital implant versus 3D preformed titanium mesh for orbital fracture repair: A retrospective comparative analysis of orbital reconstruction accuracy. Journal of Cranio-Maxillofacial Surgery. https://doi.org/10.1016/j.jcms.2024.02.012

Vancouver

Consorti G, Betti E, Catarzi L. Customized orbital implant versus 3D preformed titanium mesh for orbital fracture repair: A retrospective comparative analysis of orbital reconstruction accuracy. Journal of Cranio-Maxillofacial Surgery. 2024. doi:10.1016/j.jcms.2024.02.012

BibTeX
@article{Consorti2024,
  author = {Consorti, Giuseppe and Betti, Enrico and Catarzi, Lisa},
  title = {Customized orbital implant versus 3D preformed titanium mesh for orbital fracture repair: A retrospective comparative analysis of orbital reconstruction accuracy},
  journal = {Journal of Cranio-Maxillofacial Surgery},
  year = {2024},
  doi = {10.1016/j.jcms.2024.02.012}
}
Kostenlos starten →