Cardiac Computed Tomography for Quantification of Myocardial Extracellular Volume Fraction
JACC: Cardiovascular Imaging · 2023-10 · 16 (10) · 1306-1317
DOI: 10.1016/j.jcmg.2023.03.021 ↗Kurz gefasst
Metaanalyse in der Zeitschrift JACC: Cardiovascular Imaging, 2023-10. Verfasst von Donghee Han und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Imaging and Medicine, Cedars-Sinai Medical Center, Los Angeles, California, USA. Hauptthemen laut MEDLINE: Myocardium, Cardiomyopathies. Die Arbeit wurde bisher 86-mal zitiert (Crossref) und nennt 37 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Extracellular volume (ECV) is a quantitative measure of extracellular compartment expansion, and an increase in ECV is a marker of myocardial fibrosis. Although cardiac magnetic resonance (CMR) is considered the standard imaging tool for ECV quantification, cardiac computed tomography (CT) has also been used for ECV assessment. OBJECTIVES: The aim of this meta-analysis was to evaluate the correlation and agreement in the quantification of myocardial ECV by CT and CMR. METHODS: PubMed and Web of Science were searched for relevant publications reporting on the use of CT for ECV quantification compared with CMR as the reference standard. The authors employed a meta-analysis using the restricted maximum-likelihood estimator with a random-effects method to estimate summary correlation and mean difference. A subgroup analysis was performed to compare the correlation and mean differences between single-energy CT (SECT) and dual-energy CT (DECT) techniques for the ECV quantification. RESULTS: Of 435 papers, 13 studies comprising 383 patients were identified. The mean age range was 57.3 to 82 years, and 65% of patients were male. Overall, there was an excellent correlation between CT-derived ECV and CMR-derived ECV (mean: 0.90 [95% CI: 0.86-0.95]). The pooled mean difference between CT and CMR was 0.96% (95% CI: 0.14%-1.78%). Seven studies reported correlation values using SECT, and 4 studies reported those using DECT. The pooled correlation from studies utilizing DECT for ECV quantification was significantly higher compared with those with SECT (mean: 0.94 [95% CI: 0.91-0.98] vs 0.87 [95% CI: 0.80-0.94], respectively; P = 0.01). There was no significant difference in pooled mean differences between SECT vs DECT (P = 0.85). CONCLUSIONS: CT-derived ECV showed an excellent correlation and mean difference of
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Imaging and Medicine, Cedars-Sinai Medical Center, Los Angeles, California, USA.
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA.
- Department of Imaging and Medicine, Cedars-Sinai Medical Center, Los Angeles, California, USA. Electronic address: Daniel.Berman@cshs.org.
- Cardiovascular Institute, Indiana University School of Medicine, Indianapolis, Indiana, USA.
Zitieren
APA
Han, D., Lin, A., Kuronuma, K., Gransar, H., Dey, D., Friedman, J. D., Berman, D. S., & Tamarappoo, B. K. (2023). Cardiac Computed Tomography for Quantification of Myocardial Extracellular Volume Fraction. JACC: Cardiovascular Imaging, 16(10), 1306-1317. https://doi.org/10.1016/j.jcmg.2023.03.021
Vancouver
Han D, Lin A, Kuronuma K, Gransar H, Dey D, Friedman JD, et al. Cardiac Computed Tomography for Quantification of Myocardial Extracellular Volume Fraction. JACC: Cardiovascular Imaging. 2023;16(10):1306-1317. doi:10.1016/j.jcmg.2023.03.021
BibTeX
@article{Han2023,
author = {Han, Donghee and Lin, Andrew and Kuronuma, Keiichiro and Gransar, Heidi and Dey, Damini and Friedman, John D and Berman, Daniel S and Tamarappoo, Balaji K},
title = {Cardiac Computed Tomography for Quantification of Myocardial Extracellular Volume Fraction},
journal = {JACC: Cardiovascular Imaging},
year = {2023},
volume = {16},
number = {10},
pages = {1306--1317},
doi = {10.1016/j.jcmg.2023.03.021}
}
EUVIMED