EUVIMEDEUVIMED entdecken
Open Access

Accuracy of the Diagnostic Tests of Sacroiliac Joint Dysfunction

Parisa Nejati, Elham Sartaj, Farnad Imani, Reza Moeineddin, Lida Nejati, Marta Safavi

Journal of Chiropractic Medicine · 2020-03 · 19 (1) · 28-37

DOI: 10.1016/j.jcm.2019.12.002 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Chiropractic Medicine, 2020-03. Verfasst von Parisa Nejati und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Sports and Exercise Medicine, Rasool Akram Hospital, Iran University of Medical Sciences, Tehran, Iran. Die Arbeit wurde bisher 34-mal zitiert (Crossref) und nennt 72 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: The purpose of this study was to assess the reliability and validity of motion palpation and pain provocation compared with sacroiliac joint (SIJ) block as the gold-standard assessment method of patients with sacroiliac joint dysfunction (SIJD). METHODS: A cross-sectional study was conducted in the Department of Sports and Exercise Medicine at Rasool Akram Hospital. Forty-eight patients suspected of having SIJD were selected from a total of 150 patients on the basis of a combination of symptoms, physical tests, and magnetic resonance imaging findings. The patients suspected of having SIJD received the SIJ block, to which the accuracy of all the physical tests was compared. Sensitivity, specificity, and positive and negative predictive values were calculated for each test. The receiver operating characteristic curve and the area under the receiver operating characteristic curve were measured. RESULTS: The Flexion, Abduction and External Rotation (FABER) test had the highest specificity and positive predictive values of the physical tests. Furthermore, the combination of the FABER test and the thigh thrust test improved overall diagnostic ability more so than any of the other test combinations. CONCLUSION: A combination of the motion and provocation tests increased specificity and positive predictive values, and the FABER test had the highest of these single values. The palpation tests did not change after the SIJ block, suggesting that their accuracy cannot be determined using this method.

Schlagwörter

Stichwörter der Autor:innen

Diagnostic TestsPredictive Value of TestsSensitivity and Specificity

Autor:innen und Institutionen

  • Department of Sports and Exercise Medicine, Rasool Akram Hospital, Iran University of Medical Sciences, Tehran, Iran.
  • Department of Anesthesiology and Pain Medicine, Rasool Akram Hospital, Iran University of Medical Sciences, Tehran, Iran.
  • Dr. Moeineddin Radiology Clinic, Qazvin, Iran.
  • Islamic Azad University, Science and Research Branch, Tehran, Iran.

Zitieren

APA

Nejati, P., Sartaj, E., Imani, F., Moeineddin, R., Nejati, L., & Safavi, M. (2020). Accuracy of the Diagnostic Tests of Sacroiliac Joint Dysfunction. Journal of Chiropractic Medicine, 19(1), 28-37. https://doi.org/10.1016/j.jcm.2019.12.002

Vancouver

Nejati P, Sartaj E, Imani F, Moeineddin R, Nejati L, Safavi M. Accuracy of the Diagnostic Tests of Sacroiliac Joint Dysfunction. Journal of Chiropractic Medicine. 2020;19(1):28-37. doi:10.1016/j.jcm.2019.12.002

BibTeX
@article{Nejati2020,
  author = {Nejati, Parisa and Sartaj, Elham and Imani, Farnad and Moeineddin, Reza and Nejati, Lida and Safavi, Marta},
  title = {Accuracy of the Diagnostic Tests of Sacroiliac Joint Dysfunction},
  journal = {Journal of Chiropractic Medicine},
  year = {2020},
  volume = {19},
  number = {1},
  pages = {28--37},
  doi = {10.1016/j.jcm.2019.12.002}
}
Kostenlos starten →