Efficacy and safety of bent ab interno needle goniotomy: a systematic review and meta-analysis
Canadian Journal of Ophthalmology · 2026-10
DOI: 10.1016/j.jcjo.2026.08.024 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Canadian Journal of Ophthalmology, 2026-10. Verfasst von Faizan Naveed und 7 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine, University of Ottawa, Ottawa, ON. Electronic address: fnave070@uottawa.ca. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
OBJECTIVE: To evaluate the effectiveness and safety of bent ab interno needle goniotomy (BANG) for glaucoma through systematic review and meta-analysis. BANG is a device-free trabecular meshwork-excisional, minimally invasive glaucoma surgery that may offer a lower-cost, more accessible alternative to device-based angle surgery, but its efficacy and safety profile have not been comprehensively consolidated. METHODS: MEDLINE, Embase, Cochrane CENTRAL, Scopus, and Web of Science were searched from inception until December 14, 2025. Eligible studies included ≥10 eyes undergoing stand-alone or combined phaco-BANG. Two reviewers independently screened and extracted data; risk of bias was assessed using ROBINS-I v2/RoB-2 and certainty using GRADE. Random-effects inverse-variance meta-analyses pooled intra-ocular pressure (IOP) change at 6 and 12 months and anti-glaucoma medication (AGM) reduction at 6 months; hyphema incidence was pooled using proportional meta-analysis. Leave-one-out and subgroup analyses were performed. RESULTS: Fourteen studies met inclusion criteria. Across 10 cohorts (248 eyes), IOP decreased by 4.74 mm Hg (95% CI: 2.13-7.35; I² = 96.2%) at 6 months following BANG-containing procedures (predominantly phaco-BANG). Likewise, across 6 cohorts (140 eyes), 12-month IOP reduction was 4.88 mm Hg (0.44-9.31; I² = 98.0%). Across 6 cohorts (161 eyes), AGM burden decreased by 1.30 medications (0.86-1.74; I² = 85.7%). Across 11 cohorts (261 eyes), pooled hyphema incidence was 0.33 (0.14-0.55; I² = 93.3%). Leave-one-out and design-restricted analyses reduced heterogeneity and attenuated effect sizes, suggesting more conservative estimates of efficacy. Certainty of evidence was low. CONCLUSIONS: BANG-containing procedures are associated with modest IOP and medication reductions, with a substantial but typically transient hyphema risk. However, the predominantly phaco-BANG evidence base cannot isolate the independent or clinically meaningful contribution of BANG. Small samples, substantial heterogeneity, limited washout IOP reporting, and low-certainty evidence, support cautious interpretation.
Autor:innen und Institutionen
- Faculty of Medicine, University of Ottawa, Ottawa, ON. Electronic address: fnave070@uottawa.ca.
- Department of Ophthalmology and Vision Science, University of Toronto, Toronto, ON.
- Department of Ophthalmology, Faculty of Medicine, University of Ottawa, ON.
- Department of Ophthalmology, Washington University, St. Louis, MO.
Zitieren
APA
Naveed, F., Ahmed, Y., Lo, C., Sim, W., Kherani, I., Schlenker, M. B., Beckman, J., & Sheybani, A. (2026). Efficacy and safety of bent ab interno needle goniotomy: a systematic review and meta-analysis. Canadian Journal of Ophthalmology. https://doi.org/10.1016/j.jcjo.2026.08.024
Vancouver
Naveed F, Ahmed Y, Lo C, Sim W, Kherani I, Schlenker MB, et al. Efficacy and safety of bent ab interno needle goniotomy: a systematic review and meta-analysis. Canadian Journal of Ophthalmology. 2026. doi:10.1016/j.jcjo.2026.08.024
BibTeX
@article{Naveed2026,
author = {Naveed, Faizan and Ahmed, Yusuf and Lo, Cody and Sim, Wei and Kherani, Irfan and Schlenker, Matthew B and Beckman, Jamie and Sheybani, Arsham},
title = {Efficacy and safety of bent ab interno needle goniotomy: a systematic review and meta-analysis},
journal = {Canadian Journal of Ophthalmology},
year = {2026},
doi = {10.1016/j.jcjo.2026.08.024}
}
EUVIMED