Evaluation of a comatic aberration-based nomogram for symmetrical intracorneal ring segment implantation in keratoconus
Canadian Journal of Ophthalmology · 2026
DOI: 10.1016/j.jcjo.2026.01.021 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Canadian Journal of Ophthalmology, 2026. Verfasst von Nicole Mechleb und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Rothschild Foundation, Paris, France. Hauptthemen laut MEDLINE: Keratoconus, Visual Acuity, Corneal Stroma, Prosthesis Implantation. Die Arbeit nennt 17 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE: The aim of this study was to evaluate the short-term results of a comatic aberration-based nomogram of intrastromal corneal ring segments in different keratoconus patterns and stages. SETTING: Hospital Foundation Adolphe de Rothschild-Noémie de Rothschild Institute. DESIGN: A retrospective observational single-center study. METHODS: This study includes patients who underwent intracorneal ring segment implantation with Kc Solutions rings from January 2018 to December 2022. A complete ocular examination was performed preoperatively: uncorrected (UDVA) and best-corrected distance visual acuity (CDVA), slit lamp anterior segment, and fundus examination. Corneal topography was performed with the Pentacam HR system. RESULTS: Ninety-one eyes of 68 patients were included. Both UDVA and CDVA improved significantly from 0.47 ± 0.23 logMAR and 0.39 ± 0.25 logMAR at baseline to 0.34 ± 0.32 logMAR and 0.17 ± 0.19 logMAR after 3 months. A significant decrease of 2.13 ± 2.44 D in cylinder and 2.12 ± 3.06 D in SE was observed (p < 0.001). The Astigmatic Index of Success (AIS) was 0.43 ± 0.49, and 49 eyes (53.8%) had a decrease in cylinder of more than 50%. The flattest (K1) and steepest (K2) meridians, and maximum keratometry (Kmax) decreased at 3 months. The y value of the steepest point showed a significant upper shift (p = 0.007). Total RMS, higher-order aberration (HOA) RMS, and comatic aberrations all decreased significantly postoperatively (p < 0.001). CONCLUSIONS: The present study demonstrates that targeting vertical coma can reduce total RMS and HOA aberrations in addition to improving topographic and refractive outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Ophthalmology, Rothschild Foundation, Paris, France.
- Department of Ophthalmology, Rothschild Foundation, Paris, France. Electronic address: christophepanthier@gmail.com.
- Department of Ophthalmology, Rothschild Foundation, Paris, France; Center of Expertise and Research in Optics for Vision, Paris, France.
Zitieren
APA
Mechleb, N., Panthier, C., Fabro, F., Elahi, S., Stephan, S., Saad, A., & Gatinel, D. (2026). Evaluation of a comatic aberration-based nomogram for symmetrical intracorneal ring segment implantation in keratoconus. Canadian Journal of Ophthalmology. https://doi.org/10.1016/j.jcjo.2026.01.021
Vancouver
Mechleb N, Panthier C, Fabro F, Elahi S, Stephan S, Saad A, et al. Evaluation of a comatic aberration-based nomogram for symmetrical intracorneal ring segment implantation in keratoconus. Canadian Journal of Ophthalmology. 2026. doi:10.1016/j.jcjo.2026.01.021
BibTeX
@article{Mechleb2026,
author = {Mechleb, Nicole and Panthier, Christophe and Fabro, Fillipo and Elahi, Sina and Stephan, Sophie and Saad, Alain and Gatinel, Damien},
title = {Evaluation of a comatic aberration-based nomogram for symmetrical intracorneal ring segment implantation in keratoconus},
journal = {Canadian Journal of Ophthalmology},
year = {2026},
doi = {10.1016/j.jcjo.2026.01.021}
}