EUVIMEDEUVIMED entdecken
Crossref

Quantifying the repeatability and reproducibility of Dr. Noon CVD, AI software as medical device for cardiovascular risk assessment via retinal imaging

Rim Kyung Hong, Moonsu Kim, Eun Hee Hong, Min Ho Kang, Yong Un Shin, Hwan-Cheol Park, Sunjin Hwang

Canadian Journal of Ophthalmology · 2026

DOI: 10.1016/j.jcjo.2025.07.008 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Canadian Journal of Ophthalmology, 2026. Verfasst von Rim Kyung Hong und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Hanyang University Guri Hospital, Guri City, South Korea. Hauptthemen laut MEDLINE: Cardiovascular Diseases, Software, Artificial Intelligence, Retina. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 34 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: To evaluate the repeatability and reproducibility of the Dr.Noon CVD, an artificial intelligence software as a medical device that assesses cardiovascular risk from retinal photographs by providing risk scores and classifying patients into three categories: category 0 (low risk), category 1 (intermediate risk), and category 2 (high risk). METHODS: In this prospective, single-center study, participants underwent nonmydriatic fundus photography. For repeatability assessment, one examiner captured 3 consecutive images per eye. For reproducibility, a second examiner independently acquired 1 image per eye. Intraclass correlation coefficients (ICCs), within-subject standard deviations, and coefficients of variation were calculated. Differences by risk category and lens status were assessed using ANOVA and independent t tests. RESULTS: Overall, Dr.Noon CVD demonstrated excellent reliability, with a repeatability ICC of 0.997 (95% confidence interval [CI]: 0.996-0.998) and a reproducibility ICC of 0.999 (95% CI: 0.998-0.999). When analyzed by risk categories, repeatability, and reproducibility ICCs were 0.985 (95% CI: 0.974-0.997) and 0.995 (95% CI: 0.990-0.997) for category 0, 0.960 (95% CI: 0.918-0.983) and 0.969 (95% CI: 0.921-0.988) for category 1, and 0.965 (95% CI: 0.943-0.980) and 0.984 (95% CI: 0.971-0.992) for category 2. In terms of lens status, phakic eyes showed repeatability and reproducibility ICCs of 0.998 (95% CI: 0.996-0.998) and 0.999 (95% CI: 0.998-0.999), respectively, while pseudophakic eyes showed slightly lower but still excellent values of 0.989 (95% CI: 0.980-0.995) and 0.994 (95% CI: 0.988-0.997). CONCLUSIONS: Dr.Noon CVD demonstrated high precision with excellent repeatability and reproducibility across all risk levels and lens statuses, supporting its reliability for cardiovascular risk screening using retinal images.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cardiovascular DiseasesSoftwareArtificial IntelligenceRetinaDiabetic RetinopathyHumansReproducibility of ResultsProspective StudiesFemaleMaleMiddle AgedRisk AssessmentAgedPhotographyAdult

Autor:innen und Institutionen

  • Department of Ophthalmology, Hanyang University Guri Hospital, Guri City, South Korea.
  • Department of Ophthalmology, Hanyang University Guri Hospital, Guri City, South Korea; Hanyang Institute of Bioscience and Biotechnology, Hanyang University, Seoul, South Korea; Hanyang University College of Medicine, S…
  • Department of Ophthalmology, Hanyang University Guri Hospital, Guri City, South Korea; Hanyang University College of Medicine, Seoul, South Korea.
  • Department of Cardiology, Hanyang University Guri Hospital, Guri City, South Korea; Hanyang University College of Medicine, Seoul, South Korea.
  • Department of Ophthalmology, Hanyang University Guri Hospital, Guri City, South Korea; Hanyang University College of Medicine, Seoul, South Korea. Electronic address: sunjin1989@hanyang.ac.kr.

Zitieren

APA

Hong, R. K., Kim, M., Hong, E. H., Kang, M. H., Shin, Y. U., Park, H. C., & Hwang, S. (2026). Quantifying the repeatability and reproducibility of Dr. Noon CVD, AI software as medical device for cardiovascular risk assessment via retinal imaging. Canadian Journal of Ophthalmology. https://doi.org/10.1016/j.jcjo.2025.07.008

Vancouver

Hong RK, Kim M, Hong EH, Kang MH, Shin YU, Park HC, et al. Quantifying the repeatability and reproducibility of Dr. Noon CVD, AI software as medical device for cardiovascular risk assessment via retinal imaging. Canadian Journal of Ophthalmology. 2026. doi:10.1016/j.jcjo.2025.07.008

BibTeX
@article{Hong2026,
  author = {Hong, Rim Kyung and Kim, Moonsu and Hong, Eun Hee and Kang, Min Ho and Shin, Yong Un and Park, Hwan-Cheol and Hwang, Sunjin},
  title = {Quantifying the repeatability and reproducibility of Dr. Noon CVD, AI software as medical device for cardiovascular risk assessment via retinal imaging},
  journal = {Canadian Journal of Ophthalmology},
  year = {2026},
  doi = {10.1016/j.jcjo.2025.07.008}
}
Kostenlos starten →