Clinical outcomes of a trifocal compared with an extended depth of focus IOL following bilateral cataract surgery
Canadian Journal of Ophthalmology · 2023-10 · 58 (5) · 393-400
DOI: 10.1016/j.jcjo.2022.05.005 ↗Kurz gefasst
Fachartikel in der Zeitschrift Canadian Journal of Ophthalmology, 2023-10. Verfasst von Marius A Scheepers und 3 weiteren Autor:innen. Beteiligte Einrichtung: University of British Columbia, Kelowna, B.C.. Electronic address: 220eyes@gmail.com. Hauptthemen laut MEDLINE: Cataract Extraction, Lenses, Intraocular, Cataract, Phacoemulsification. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 11 Literaturangaben. Gefördert von: Alcon Laboratories Inc.
Abstract (Originalsprache)
OBJECTIVE: To compare the visual and patient reported outcomes of 2 presbyopia-correcting intraocular lenses (IOLs). METHODS: A total of 134 eyes (67 patients) that underwent cataract surgery with either a trifocal IOL or an extended depth of focus (EDOF) IOL bilaterally and were assessed 3 months after surgery. Outcome measures were binocular distance-corrected visual acuity at near (40 cm), intermediate (60 cm), and distance (6 m); Akman modified Quality of Life (QOL) Questionnaire-14; and 10% contrast visual acuity at distance and near, with and without glare. RESULTS: Mean binocular logMAR visual acuity (VA) for the PanOptix compared with the Symfony lenses: distance-corrected near VA, 0.054 versus 0.228; distance-corrected intermediate VA, 0.019 versus 0.063; and distance-corrected distance VA, -0.016 versus -0.021. The QOL questionnaire showed that 62% of the PanOptix group and 48% of the Symfony group had little or no difficulty with all QOL-related tasks. In a multivariable model controlling for pupil size and angle kappa (chord mu distance, right eyes), the differences were -0.005 (range, -0.03-0.02) and 0.165 (range, 0.12-0.21), respectively. Also, 10% contrast acuity was comparable in the 2 different lenses and was unaffected by glare. CONCLUSIONS: Binocular distance-corrected near VA was significantly better in the PanOptix group (p < 0.0001). This result remained statistically significant after controlling for pupil size and chord mu distance (p < 0.001). Intermediate and distance VAs were similar between the 2 groups. QOL scores were higher in the PanOptix group.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- University of British Columbia, Kelowna, B.C.. Electronic address: 220eyes@gmail.com.
- London School of Hygiene and Tropical Medicine, London, United Kingdom.
- Moorfields Eye Hospital and UCL Institute of Ophthalmology, London, United Kingdom.
- Sengi, Penniac, N.B.
Förderung
- Alcon Laboratories Inc
Zitieren
APA
Scheepers, M. A., Bunce, C. B., Michaelides, M., & Hall, B. (2023). Clinical outcomes of a trifocal compared with an extended depth of focus IOL following bilateral cataract surgery. Canadian Journal of Ophthalmology, 58(5), 393-400. https://doi.org/10.1016/j.jcjo.2022.05.005
Vancouver
Scheepers MA, Bunce CB, Michaelides M, Hall B. Clinical outcomes of a trifocal compared with an extended depth of focus IOL following bilateral cataract surgery. Canadian Journal of Ophthalmology. 2023;58(5):393-400. doi:10.1016/j.jcjo.2022.05.005
BibTeX
@article{Scheepers2023,
author = {Scheepers, Marius A and Bunce, Catey B and Michaelides, Michel and Hall, Brad},
title = {Clinical outcomes of a trifocal compared with an extended depth of focus IOL following bilateral cataract surgery},
journal = {Canadian Journal of Ophthalmology},
year = {2023},
volume = {58},
number = {5},
pages = {393--400},
doi = {10.1016/j.jcjo.2022.05.005}
}
EUVIMED