EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

TECTONIC CAD

Eric A Secemsky, Ziad A Ali, Evan Shlofmitz, Bassem M Chehab, Allen Jeremias, William Nicholson, Pratik Sandesara, Sameh Sayfo, Louis Verreault-Julien, Azeem Latib, Christopher Haddad, Rudy Haddad und 31 weitere

JACC: Cardiovascular Interventions · 2026-11

DOI: 10.1016/j.jcin.2026.10.002 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JACC: Cardiovascular Interventions, 2026-11. Verfasst von Eric A Secemsky und 42 weiteren Autor:innen. Beteiligte Einrichtung: Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts, USA. Electronic address: esecemsk@bidmc.harvard.edu. Die Arbeit nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Abbott Vascular.

AbstractSchlagwörterBibliografische AngabenZitieren

Abstract (Originalsprache)

BACKGROUND: Severe coronary calcification complicates percutaneous coronary intervention by limiting lesion compliance and impairing stent expansion. OBJECTIVES: To evaluate the safety and effectiveness of the SonicForce Coronary Intravascular Lithotripsy System (Abbott Vascular) in severely calcified de novo coronary lesions. METHODS: TECTONIC CAD intravascular lithotripsy investigational device exemption (NCT06885177) was a prospective, multicenter, single-arm study of 335 patients at 40 U.S. CENTERS: The primary safety endpoint was 30-day target lesion failure, defined as cardiac death, target-vessel myocardial infarction, or clinically driven target lesion revascularization. The primary effectiveness endpoint was procedural success. Each endpoint was tested against a prespecified performance goal. A prespecified optical coherence tomography (OCT) substudy evaluated calcium modification and stent expansion. RESULTS: A total of 335 patients were included in the full analysis set, with 330 and 334 as the evaluable populations for the primary safety and primary effectiveness endpoints, respectively, and a median follow-up duration of 36 days (Q1-Q3: 28-37 days). Thirty-day target lesion failure was 0.3% (1 of 330; exact 2-sided 95% CI: 0.0%-1.7%); the upper 1-sided 97.5% confidence bound was 1.7%, below the 12.9% performance goal (P < 0.0001). Procedural success was 97.0% (324 of 334; exact 2-sided 95% CI: 94.6%-98.6%); the lower 1-sided 97.5% confidence bound was 94.6%, above the 87.1% performance goal (P < 0.0001). In the OCT substudy, mean calcium length was 22.2 ± 10.3 mm, and the maximum contiguous calcium site had a calcium arc of 247.3 ± 99.0° and a thickness of 0.90 ± 0.25 mm at baseline. At this site, final stent area was 7.1 ± 1.9 mm2, with stent expansion of 95.9% ± 18.6%. Calcium fracture was identified in 62.5% (50 of 80) of lesions after intravascular lithotripsy and 66.3% (53 of 80) after stenting. CONCLUSIONS: TECTONIC CAD met both prespecified coprimary safety and effectiveness endpoints, demonstrating low 30-day target lesion failure and high procedural success. OCT demonstrated calcium fracture and favorable stent expansion at maximum contiguous calcium.

Schlagwörter

Stichwörter der Autor:innen

coronary artery calcificationintravascular lithotripsyintravascular ultrasoundlesion preparationoptical coherence tomographystent expansion

Autor:innen und Institutionen

  • Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts, USA. Electronic address: esecemsk@bidmc.harvard.edu.
  • St Francis Hospital & Heart Center, Roslyn, New York, USA.
  • Ascension Via Christi St Francis, Wichita, Kansas, USA.
  • Emory University Hospital, Atlanta, Georgia, USA.
  • Baylor Scott & White The Heart Hospital-Plano, Plano, Texas, USA.
  • Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, New York, USA.

Förderung

  • Abbott Vascular

Zitieren

APA

Secemsky, E. A., Ali, Z. A., Shlofmitz, E., Chehab, B. M., Jeremias, A., Nicholson, W., Sandesara, P., Sayfo, S., Verreault-Julien, L., Latib, A., Haddad, C., Haddad, R., Stoler, R. C., Osborn, E. A., Abela, O., Smith, J., Manthripragada, G., Ben-Dor, I., Hashim, H., …, & Kearney, K. E. (2026). TECTONIC CAD. JACC: Cardiovascular Interventions. https://doi.org/10.1016/j.jcin.2026.10.002

Vancouver

Secemsky EA, Ali ZA, Shlofmitz E, Chehab BM, Jeremias A, Nicholson W, et al. TECTONIC CAD. JACC: Cardiovascular Interventions. 2026. doi:10.1016/j.jcin.2026.10.002

BibTeX
@article{Secemsky2026,
  author = {Secemsky, Eric A and Ali, Ziad A and Shlofmitz, Evan and Chehab, Bassem M and Jeremias, Allen and Nicholson, William and Sandesara, Pratik and Sayfo, Sameh and Verreault-Julien, Louis and Latib, Azeem and Haddad, Christopher and Haddad, Rudy and Stoler, Robert C and Osborn, Eric A and Abela, Oliver and Smith, James and Manthripragada, Gopi and Ben-Dor, Itsik and Hashim, Hayder and Kiss, Daniel and Rosenberg, Jonathan and Syed, Mubbasher and Sandoval, Yader and Beohar, Nirat and Allana, Salman S and Mannino, Salvatore and Schmidt, Torrey and Mehrle, Anderson and Flaherty, James D and Mukarram, Osama and Choi, Calvin and Dohad, Suhail and Moussa, Issam and Chester, Rebecca and Popma, Jeffrey J and Maehara, Akiko and Johnson, Gayle and Kraemer, Carlye and Pingle, Sandeep C and Martinsen, Brad J and Meinen, Jennifer M and Korngold, Ethan C and Kearney, Kathleen E},
  title = {TECTONIC CAD},
  journal = {JACC: Cardiovascular Interventions},
  year = {2026},
  doi = {10.1016/j.jcin.2026.10.002}
}
Kostenlos starten →