Calcium Fracture Detection by Optical Coherence Tomography Versus Intravascular Ultrasound Following Intravascular Lithotripsy
JACC: Cardiovascular Interventions · 2026
DOI: 10.1016/j.jcin.2026.07.053 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift JACC: Cardiovascular Interventions, 2026. Verfasst von Takamasa Tanaka und 14 weiteren Autor:innen. Beteiligte Einrichtung: CVPath Institute Inc, Gaithersburg, Maryland, USA. Hauptthemen laut MEDLINE: Tomography, Optical Coherence, Ultrasonography, Interventional, Coronary Vessels, Lithotripsy. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Johnson & Johnson MedTech.
Abstract (Originalsprache)
BACKGROUND: Calcium fracture is a metric used to assess lesion preparation success. We have shown previously that optical coherence tomography (OCT) misses approximately half of these fractures. Intravascular ultrasound (IVUS) is the most commonly used intravascular imaging modality. The sensitivity of IVUS for detecting calcium fractures after intravascular lithotripsy (IVL) is unknown. OBJECTIVES: This study sought to assess the frequency and characteristics of calcium fracture observed on IVUS in comparison to OCT and gold standard micro-computed tomography (micro-CT) using heavily calcified coronary artery cadaveric vessels. METHODS: In an ex vivo study of 5 cadaveric hearts (15 coronary lesions), OCT, IVUS, and micro-CT were obtained before and after IVL coronary artery treatment. Fracture detection rates and appearance patterns were compared across modalities. Receiver operating characteristic analyses evaluated OCT-measured fracture width thresholds for IVUS detectability. RESULTS: Compared with micro-CT, OCT and IVUS significantly underestimated fracture occurrence, but OCT demonstrated higher detection sensitivity than IVUS (P 115 μm on OCT were identified by IVUS with excellent diagnostic performance (area under the curve: 0.99 [95% CI: 0.98-1.00], sensitivity 100%, specificity 92%). CONCLUSIONS: OCT and IVUS underestimate the occurrence of IVL-induced calcium fractures compared with micro-CT, with IVUS demonstrating lower sensitivity than OCT. IVUS detectability is strongly dependent on fracture width. Absence of visible fracture on either OCT or IVUS does not exclude calcium modification.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- CVPath Institute Inc, Gaithersburg, Maryland, USA.
- Heartlands Hospital, University Hospitals, Birmingham, United Kingdom.
- St Francis Hospital & Heart Center, Roslyn, New York, USA.
- Shockwave Medical, Santa Clara, California, USA.
- CVPath Institute Inc, Gaithersburg, Maryland, USA; University of Maryland, School of Medicine, Baltimore, Maryland, USA. Electronic address: afinn@cvpath.org.
- St Francis Hospital & Heart Center, Roslyn, New York, USA; New York Institute of Technology, Old Westbury, New York, USA. Electronic address: ziad.ali@dcvi.org.
Förderung
- Johnson & Johnson MedTech
Zitieren
APA
Tanaka, T., Basavarajaiah, S., Madra, A., Adachi, Y., Kawakami, R., Shin, D., Shiraki, T., Nakayama, T., Fujiyoshi, K., Hamana, T., Grogan, A., Virmani, R., West, N. E. J., Finn, A. V., & Ali, Z. A. (2026). Calcium Fracture Detection by Optical Coherence Tomography Versus Intravascular Ultrasound Following Intravascular Lithotripsy. JACC: Cardiovascular Interventions. https://doi.org/10.1016/j.jcin.2026.07.053
Vancouver
Tanaka T, Basavarajaiah S, Madra A, Adachi Y, Kawakami R, Shin D, et al. Calcium Fracture Detection by Optical Coherence Tomography Versus Intravascular Ultrasound Following Intravascular Lithotripsy. JACC: Cardiovascular Interventions. 2026. doi:10.1016/j.jcin.2026.07.053
BibTeX
@article{Tanaka2026,
author = {Tanaka, Takamasa and Basavarajaiah, Sandeep and Madra, Anna and Adachi, Yusuke and Kawakami, Rika and Shin, Doosup and Shiraki, Tatsuya and Nakayama, Takafumi and Fujiyoshi, Kazuhiro and Hamana, Tomoyo and Grogan, Alyssa and Virmani, Renu and West, Nick E J and Finn, Aloke V and Ali, Ziad A},
title = {Calcium Fracture Detection by Optical Coherence Tomography Versus Intravascular Ultrasound Following Intravascular Lithotripsy},
journal = {JACC: Cardiovascular Interventions},
year = {2026},
doi = {10.1016/j.jcin.2026.07.053}
}
EUVIMED