A Proposed Anatomical-Fluoroscopic Workflow to Identify the Optimal Split Line for Leaflet Modification in Redo-TAVR
JACC: Cardiovascular Interventions · 2026-06 · 19 (11) · 1469-1486
DOI: 10.1016/j.jcin.2026.04.007 ↗Kurz gefasst
Fachartikel in der Zeitschrift JACC: Cardiovascular Interventions, 2026-06. Verfasst von Takayuki Onishi und 22 weiteren Autor:innen. Beteiligte Einrichtung: Mount Sinai Fuster Heart Hospital, New York, New York, USA. Hauptthemen laut MEDLINE: Aortic Valve, Heart Valve Prosthesis, Workflow, Transcatheter Aortic Valve Replacement. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 10 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND The optimal leaflet modification strategy in redo transcatheter aortic valve replacement (TAVR) needs further refinement. OBJECTIVES The aims of this study were to clarify the anatomical relationship between transcatheter aortic valve leaflets and related structures by assessing leaflet suture lines, nodes, and commissural tabs and to propose a workflow to guide leaflet modification in redo-TAVR. METHODS The leaflet suture line and its relationship with nodes and commissural posts on the frames of SAPIEN 3, Evolut, Navitor, and ACURATE neo2 transcatheter aortic valves were identified. Leaflet regions were classified as modifiable, challenging, or nonmodifiable. Vertical leaflet split lines within the modifiable zone were proposed, and the lowest node along each split line was identified as a fluoroscopic landmark to guide leaflet modification. Preprocedural computed tomography helped determine the relationship between commissural orientation and coronary ostia to identify ideal split line(s) in proximity to the ostia to avoid obstruction. RESULTS For each valve type, the leaflet suture line and its relationship to commissural posts and valve frame were visible at multiple perspectives. The number and respective lengths of proposed split lines were identified (SAPIEN 3, A-D, 6.0-16.0 mm; Evolut, A-E, 5.0-13.0 mm; Navitor, A-C, 10.0-23.0 mm; and ACURATE neo2, A-D, 7.0-18.0 mm). Preprocedural computed tomography identified the ideal split line(s) facing the coronary ostia. A 4-step workflow to guide leaflet modification in redo-TAVR was proposed. CONCLUSIONS The authors propose a systematic, imaging-guided approach to leaflet modification in redo-TAVR. Further studies are ongoing to evaluate and validate its feasibility and effectiveness.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Mount Sinai Fuster Heart Hospital, New York, New York, USA.
- Baylor College of Medicine, Michael E. DeBakey VA Medical Center, Houston, Texas, USA.
- Cardiology Division, Department of Medicine, School of Clinical Medicine, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong SAR, China.
- Prince Charles Hospital, Brisbane, Australia.
- Ascension Alexian Medical Center, Elk Grove Village, Illinois, USA.
- Minneapolis Heart Institute Foundation, Minneapolis, Minnesota, USA.
Zitieren
APA
Onishi, T., Kini, A. S., Zaid, S., Alston Conrad Chiu, H. O., Cheung-Chi Lam, S., Eric Chan, K. Y., Poon, K., Khera, S., Hooda, A., Goel, S., Penta, B., Safi, L. M., Lerakis, S., Dangas, G. D., Sharma, S. K., Pop, A., Bapat, V. N., Fukui, M., Fukuhara, S., …, & Tang, G. H. L. (2026). A Proposed Anatomical-Fluoroscopic Workflow to Identify the Optimal Split Line for Leaflet Modification in Redo-TAVR. JACC: Cardiovascular Interventions, 19(11), 1469-1486. https://doi.org/10.1016/j.jcin.2026.04.007
Vancouver
Onishi T, Kini AS, Zaid S, Alston Conrad Chiu HO, Cheung-Chi Lam S, Eric Chan KY, et al. A Proposed Anatomical-Fluoroscopic Workflow to Identify the Optimal Split Line for Leaflet Modification in Redo-TAVR. JACC: Cardiovascular Interventions. 2026;19(11):1469-1486. doi:10.1016/j.jcin.2026.04.007
BibTeX
@article{Onishi2026,
author = {Onishi, Takayuki and Kini, Annapoorna S and Zaid, Syed and Alston Conrad Chiu, Ho-On and Cheung-Chi Lam, Simon and Eric Chan, Kwong-Yue and Poon, Karl and Khera, Sahil and Hooda, Amit and Goel, Sunny and Penta, Bhavanadhar and Safi, Lucy M and Lerakis, Stamatios and Dangas, George D and Sharma, Samin K and Pop, Andrei and Bapat, Vinayak N and Fukui, Miho and Fukuhara, Shinichi and Sellers, Stephanie and De Backer, Ole and Khan, Jaffar M and Tang, Gilbert H L},
title = {A Proposed Anatomical-Fluoroscopic Workflow to Identify the Optimal Split Line for Leaflet Modification in Redo-TAVR},
journal = {JACC: Cardiovascular Interventions},
year = {2026},
volume = {19},
number = {11},
pages = {1469--1486},
doi = {10.1016/j.jcin.2026.04.007}
}
EUVIMED