Radiation Exposure to Operators in Coronary Procedures Between Left Distal and Right Conventional Radial Access
JACC: Cardiovascular Interventions · 2026-01 · 19 (2) · 160-170
DOI: 10.1016/j.jcin.2025.10.028 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift JACC: Cardiovascular Interventions, 2026-01. Verfasst von Oh-Hyun Lee und 7 weiteren Autor:innen. Beteiligte Einrichtung: Yongin Severance Hospital, Yonsei University College of Medicine, Yongin, South Korea. Hauptthemen laut MEDLINE: Radial Artery, Radiation Exposure, Occupational Exposure, Radiation Dosage. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 38 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Distal radial access (DRA) may improve vascular complications, patient comfort, and hemostasis time. DRA-associated operator radiation exposure data are limited. OBJECTIVES: The aim of this study was to compare operator radiation exposure between left DRA and right transradial access (TRA). METHODS: In this prospective, multicenter, open-label trial, 1,010 patients scheduled to undergo coronary procedures were randomly assigned in a 1:1 ratio to either the left DRA or right TRA group. The primary endpoint was operator radiation exposure, measured using a set of 3 real-time radiation detection dosimeters on the left wrist, head, and chest by 5 experienced DRA operators. The secondary endpoints included the incidence of access-site crossover, total fluoroscopy time, total procedure time, and total contrast volume used. RESULTS: The primary endpoint analysis included 1,001 patients (501 in the left DRA group and 500 in the right TRA group). No significant differences were observed in operator radiation exposure to left wrist (4.76 μSv vs 5.20 μSv; P = 0.342), head (2.00 μSv vs 1.83 μSv; P = 0.416), and chest (1.28 μSv vs 1.07 μSv; P = 0.199) between the left DRA and right TRA groups. The incidence of crossover (6.6% vs 5.2%; P = 0.416), fluoroscopy time (4.5 minutes vs 4.2 minutes; P = 0.673), procedure time (16.0 minutes vs 15.0 minutes; P = 0.314), and contrast volume (80.0 mL vs 80.0 mL; P = 0.222) were not significantly different between the 2 groups. CONCLUSIONS: During coronary procedures, no significant differences were observed in the operator radiation exposure at the left wrist, head, and chest between the left DRA and right TRA groups.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Yongin Severance Hospital, Yonsei University College of Medicine, Yongin, South Korea.
- Yongin Severance Hospital, Yonsei University College of Medicine, Yongin, South Korea. Electronic address: yongcheol@yuhs.ac.
- Department of Biomedical Systems Informatics, Yonsei University College of Medicine, Seoul, South Korea.
- Chung-Ang University Gwangmyeong Hospital, Chung-Ang University College of Medicine, Gwangmyeong, South Korea.
- Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, South Korea.
- Yongin Severance Hospital, Yonsei University College of Medicine, Yongin, South Korea. Electronic address: chodk123@yuhs.ac.
Zitieren
APA
Lee, O. H., Roh, J. W., Kim, Y., Heo, S. J., Lee, S. Y., Lee, J. H., Im, E., & Cho, D. K. (2026). Radiation Exposure to Operators in Coronary Procedures Between Left Distal and Right Conventional Radial Access. JACC: Cardiovascular Interventions, 19(2), 160-170. https://doi.org/10.1016/j.jcin.2025.10.028
Vancouver
Lee OH, Roh JW, Kim Y, Heo SJ, Lee SY, Lee JH, et al. Radiation Exposure to Operators in Coronary Procedures Between Left Distal and Right Conventional Radial Access. JACC: Cardiovascular Interventions. 2026;19(2):160-170. doi:10.1016/j.jcin.2025.10.028
BibTeX
@article{Lee2026,
author = {Lee, Oh-Hyun and Roh, Ji Woong and Kim, Yongcheol and Heo, Seok-Jae and Lee, Sang Yeub and Lee, Jung-Hee and Im, Eui and Cho, Deok-Kyu},
title = {Radiation Exposure to Operators in Coronary Procedures Between Left Distal and Right Conventional Radial Access},
journal = {JACC: Cardiovascular Interventions},
year = {2026},
volume = {19},
number = {2},
pages = {160--170},
doi = {10.1016/j.jcin.2025.10.028}
}
EUVIMED