New-Onset Conductance Disturbances After Transcatheter Tricuspid Valve Replacement
JACC: Cardiovascular Interventions · 2025-11 · 18 (21) · 2569-2579
DOI: 10.1016/j.jcin.2025.07.039 ↗Kurz gefasst
Fachartikel in der Zeitschrift JACC: Cardiovascular Interventions, 2025-11. Verfasst von Robin Le Ruz und 14 weiteren Autor:innen. Beteiligte Einrichtung: Nantes Université, CHU Nantes, Interventional Cardiology Department, l'Institut du Thorax, Nantes, France; Nantes Université, CHU Nantes, CNRS, INSER…. Hauptthemen laut MEDLINE: Tricuspid Valve, Heart Valve Prosthesis Implantation, Cardiac Catheterization, Arrhythmias, Cardiac. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 23 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: The anatomical relationship between the tricuspid annulus and the conduction system increases the risk for new-onset conductance disturbance (NOCD) following transcatheter tricuspid valve replacement (TTVR). OBJECTIVES: The aim of this study was to describe the incidence and types of NOCD and potential risk factors. METHODS: This was a single-center, retrospective analysis of TTVR patients. The primary endpoint was 30-day NOCD incidence. Subgroups with (NOCD+) and without (NOCD-) conduction disturbances were compared. Echocardiographic measures of tricuspid valve and right ventricular size, morphology, and function as well as post-TTVR computed tomographic device position within the annulus were assessed. RESULTS: A total of 70 patients were included in this analysis, of whom 31 (44.3%) developed NOCD, which included right bundle branch block, complete atrioventricular block and slow atrial fibrillation. New permanent pacemaker implantation was required in 8 patients (14%) within 30 days. Baseline absolute right ventricle free wall longitudinal strain was significantly higher in NOCD+ patients (29.7% ± 5.4% vs 25.1% ± 6.4%; P = 0.002). Type IIIB leaflet morphology was more prevalent in NOCD+ patients (48.4% vs 25.6%; P = 0.049). No difference was found regarding membranous septum (MS) dimensions or device oversizing. The postprocedural incidence of white blood cell count peak >13 × 109/L was higher in NOCD+ patients (51.6% vs 28.2%; P = 0.046). By logistic regression, the primary outcome was associated with baseline absolute right ventricle free wall longitudinal strain ≥29% and contact of subvalvular device component with the MS on follow-up computed tomography. CONCLUSIONS: NOCD incidence was 44.6% after TTVR in a highly selected patient population. Baseline hyperdynamic right ventricular function and contact of the device with the MS were independently associated with NOCD at 30 days. Further studies are warranted.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Nantes Université, CHU Nantes, Interventional Cardiology Department, l'Institut du Thorax, Nantes, France; Nantes Université, CHU Nantes, CNRS, INSERM, l'Institut du Thorax, Nantes, France; Department of Medicine, Colum…
- Department of Medicine, Columbia University Irving Medical Center, New York, New York, USA.
- California Pacific Medical Center, San Francisco, California, USA.
- Department of Medicine, Columbia University Irving Medical Center, New York, New York, USA; Department of Cardiology, University of Bern, Inselspital, Bern, Switzerland.
- Department of Medicine, Columbia University Irving Medical Center, New York, New York, USA; Division of Cardiology, Department of Medicine, Cardiovascular Imaging Center, Samsung Medical Center, Sungkyunkwan University…
- Department of Medicine, Columbia University Irving Medical Center, New York, New York, USA. Electronic address: https://twitter.com/hahn_rt.
Zitieren
APA
Le Ruz, R., Nazif, T., George, I., Wan, E. Y., Agarwal, V., Lebehn, M., Rezende, C. P., Bartkowiak, J., Kim, E. K., Tat, E., Ng, V., Vahl, T. P., Leon, M. B., Kodali, S. K., & Hahn, R. T. (2025). New-Onset Conductance Disturbances After Transcatheter Tricuspid Valve Replacement. JACC: Cardiovascular Interventions, 18(21), 2569-2579. https://doi.org/10.1016/j.jcin.2025.07.039
Vancouver
Le Ruz R, Nazif T, George I, Wan EY, Agarwal V, Lebehn M, et al. New-Onset Conductance Disturbances After Transcatheter Tricuspid Valve Replacement. JACC: Cardiovascular Interventions. 2025;18(21):2569-2579. doi:10.1016/j.jcin.2025.07.039
BibTeX
@article{LeRuz2025,
author = {Le Ruz, Robin and Nazif, Tamim and George, Isaac and Wan, Elaine Y and Agarwal, Vratika and Lebehn, Mark and Rezende, Carolina Pinheiro and Bartkowiak, Joanna and Kim, Eun Kyoung and Tat, Emily and Ng, Vivian and Vahl, Torsten P and Leon, Martin B and Kodali, Susheel K and Hahn, Rebecca T},
title = {New-Onset Conductance Disturbances After Transcatheter Tricuspid Valve Replacement},
journal = {JACC: Cardiovascular Interventions},
year = {2025},
volume = {18},
number = {21},
pages = {2569--2579},
doi = {10.1016/j.jcin.2025.07.039}
}
EUVIMED