Incidence, Predictors, and Management of Conduction Disturbances After Transcatheter Tricuspid Valve Replacement
JACC: Cardiovascular Interventions · 2025-07 · 18 (14) · 1789-1799
DOI: 10.1016/j.jcin.2025.05.029 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift JACC: Cardiovascular Interventions, 2025-07. Verfasst von Andrea Scotti und 39 weiteren Autor:innen. Beteiligte Einrichtung: Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, New York, USA. Hauptthemen laut MEDLINE: Tricuspid Valve, Atrioventricular Block, Heart Valve Prosthesis Implantation, Cardiac Pacing, Artificial. Die Arbeit wurde bisher 26-mal zitiert (Crossref) und nennt 23 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Transcatheter tricuspid valve replacement (TTVR) can induce high-grade atrioventricular block (HAVB), necessitating permanent pacemaker implantation (PPI). Limited data are available regarding this complication and management post-TTVR. OBJECTIVES: The aim of this study was to investigate the incidence, predictors, and management of conduction disturbances after TTVR. METHODS: All consecutive patients undergoing TTVR in the multicenter TRIPLACE (Global Multicenter Registry on Transcatheter Tricuspid Valve Replacement) registry were analyzed. The primary endpoint was the occurrence of HAVB at 1 month post-TTVR. RESULTS: Of 263 TTVR patients, 75 (28.5%) were excluded because of pre-existing PPI and 3 (1.1%) because of surgical conversion. At 1 month, HAVB had occurred in 25 of the remaining 185 patients (13.5%), 88% within the first week post-TTVR (median 3.0 days; Q1-Q3: 2.0-5.0). New-onset right bundle branch block was observed in 20.6% of patients. Baseline left bundle branch block or left anterior or posterior fascicular block (adjusted OR: 3.63; 95% CI: 1.28-10.37; P = 0.016) was independently associated with HAVB, after adjusting for age and degree of device oversizing. PPI was performed using leadless technologies (45.5%), coronary sinus leads (27.3%), or transvalvular dual-chamber pacemakers (27.3%). CONCLUSIONS: HAVB occurred in 13.5% of PPI-naive patients who underwent TTVR. The majority of cases of HAVB (88%) were observed in the first week after TTVR. Baseline left bundle branch block or left anterior or posterior fascicular block confers a high risk for HAVB after TTVR. (Global Multicenter Registry on Transcatheter Tricuspid Valve Replacement [TRIPLACE]; NCT06033274).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, New York, USA.
- Department of Cardiovascular Medicine, Cleveland Clinic Foundation, Cleveland, Ohio, USA. Electronic address: purir@ccf.org.
- Oregon Health and Science University, Portland, Oregon, USA.
- Centre for Heart Valve Innovation, St. Paul's Hospital, Vancouver, British Columbia, Canada.
- Division of Cardiology, Columbia University Medical Center, NewYork-Presbyterian Hospital, New York, New York, USA.
- Groupe Cardio-Vasculaire lnterventionnel, Cinique Pasteur, Toulouse, France.
Zitieren
APA
Scotti, A., Puri, R., Sturla, M., Zahr, F., Boone, R., Kodali, S., Tchétché, D., De Backer, O., Coisne, A., Ludwig, S., Stolz, L., Estevez Loureiro, R., Adam, M., De Marco, F., Ho, E. C., Cheung, A., Moey, M., Ong, G., Chadderdon, S., …, & Latib, A. (2025). Incidence, Predictors, and Management of Conduction Disturbances After Transcatheter Tricuspid Valve Replacement. JACC: Cardiovascular Interventions, 18(14), 1789-1799. https://doi.org/10.1016/j.jcin.2025.05.029
Vancouver
Scotti A, Puri R, Sturla M, Zahr F, Boone R, Kodali S, et al. Incidence, Predictors, and Management of Conduction Disturbances After Transcatheter Tricuspid Valve Replacement. JACC: Cardiovascular Interventions. 2025;18(14):1789-1799. doi:10.1016/j.jcin.2025.05.029
BibTeX
@article{Scotti2025,
author = {Scotti, Andrea and Puri, Rishi and Sturla, Matteo and Zahr, Firas and Boone, Robert and Kodali, Susheel and Tchétché, Didier and De Backer, Ole and Coisne, Augustin and Ludwig, Sebastian and Stolz, Lukas and Estevez Loureiro, Rodrigo and Adam, Matti and De Marco, Federico and Ho, Edwin C and Cheung, Anson and Moey, Melissa and Ong, Geraldine and Chadderdon, Scott and Lulic, Davorka and Bartkowiak, Joanna and Echarte, Julio and Sievert, Horst and Byrne, Timothy and Maisano, Francesco and Frerker, Christian and Dumonteil, Nicolas and Oliva, Omar A and Rudolph, Tanja K and Kirchner, Johannes and Bakhtadze, Beka and Kapadia, Samir R and Rodés-Cabau, Josep and Schofer, Niklas and Granada, Juan and Hausleiter, Jörg and Hahn, Rebecca T and Modine, Thomas and Fam, Neil and Latib, Azeem},
title = {Incidence, Predictors, and Management of Conduction Disturbances After Transcatheter Tricuspid Valve Replacement},
journal = {JACC: Cardiovascular Interventions},
year = {2025},
volume = {18},
number = {14},
pages = {1789--1799},
doi = {10.1016/j.jcin.2025.05.029}
}
EUVIMED