High-Output Mechanical Circulatory Support in Left Main Interventions
JACC: Cardiovascular Interventions · 2024-12 · 17 (24) · 2851-2862
DOI: 10.1016/j.jcin.2024.09.017 ↗Kurz gefasst
Fachartikel in der Zeitschrift JACC: Cardiovascular Interventions, 2024-12. Verfasst von Ehud Schwammenthal und 4 weiteren Autor:innen. Beteiligte Einrichtung: Sheba Medical Center, Tel HaShomer & Magenta Medical Ltd., Kadima, Israel. Electronic address: ehudsc@magentamed.com. Hauptthemen laut MEDLINE: Feasibility Studies, Ventricular Function, Left, Cardiac Catheters. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 19 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: The Magenta Elevate is a 9-F, self-expanding, catheter-mounted pump delivered sheathed through a commercially available 10-F femoral introducer over the wire to the left ventricle (LV), providing temporary hemodynamic support up to an equivalent of normal cardiac output. OBJECTIVES: The authors sought to assess the feasibility and outcomes of Elevate-supported high-risk percutaneous coronary intervention (HR-PCI) in a first-in-human study and study the hemodynamic impact of high-output support during prolonged interventional left main coronary artery (LM) occlusions. METHODS: In this study, 14 patients underwent Elevate-supported HR-PCI, with 8 patients undergoing 20 prolonged (39 ± 16 seconds) balloon occlusions of an unprotected LM. Systolic and diastolic aortic pressures, mean arterial pressure (MAP), and diastolic aorto-left ventricular pressure difference (dΔPAoLV) were determined before and during inflations. RESULTS: There were no major device-related adverse events (primary safety endpoint) and no mortality at 30 days. During prolonged LM occlusions, the following changes were observed: There was a significant drop in systolic aortic pressure (-35 mm Hg [-46 to -23 mm Hg]; P < 0.0001) accompanied by a significant increase in diastolic pressure (7 mm Hg [4 to 10 mm Hg]; P < 0.0055). MAP, which showed a small decrease (-7 mm Hg [-13 to -2 mm Hg]; P < 0.001) and dΔPAoLV (-2 mm Hg [-5 to 4 mm Hg]; P = 0.51) remained in the normal range. Ventriculo-arterial uncoupling occurred in 13 of 20 LM balloon occlusions. CONCLUSIONS: In this first-in-human study, use of the Magenta Elevate low-profile, high-output catheter during HR-PCI was safe and provided substantial cardiac support. During prolonged interventional LM occlusions, the system unloaded the LV, maintaining a normal MAP and dΔPAoLV.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Sheba Medical Center, Tel HaShomer & Magenta Medical Ltd., Kadima, Israel. Electronic address: ehudsc@magentamed.com.
- The Israeli-Georgian Medical Research Clinic "Helsicore", Tbilisi, Georgia.
- CardioVascular Center Frankfurt, Frankfurt, Germany.
- Sheba Medical Center, Tel HaShomer & Faculty of Medicine, Tel-Aviv University, Israel.
- Beth Israel Deaconess Medical Center, Boston, Massachusetts, USA. Electronic address: dpinto@bidmc.harvard.edu.
Zitieren
APA
Schwammenthal, E., Gogorishvili, I., Sievert, H., Fefer, P., & Pinto, D. S. (2024). High-Output Mechanical Circulatory Support in Left Main Interventions. JACC: Cardiovascular Interventions, 17(24), 2851-2862. https://doi.org/10.1016/j.jcin.2024.09.017
Vancouver
Schwammenthal E, Gogorishvili I, Sievert H, Fefer P, Pinto DS. High-Output Mechanical Circulatory Support in Left Main Interventions. JACC: Cardiovascular Interventions. 2024;17(24):2851-2862. doi:10.1016/j.jcin.2024.09.017
BibTeX
@article{Schwammenthal2024,
author = {Schwammenthal, Ehud and Gogorishvili, Irakli and Sievert, Horst and Fefer, Paul and Pinto, Duane S},
title = {High-Output Mechanical Circulatory Support in Left Main Interventions},
journal = {JACC: Cardiovascular Interventions},
year = {2024},
volume = {17},
number = {24},
pages = {2851--2862},
doi = {10.1016/j.jcin.2024.09.017}
}
EUVIMED