EUVIMEDEUVIMED entdecken
Crossref

Commissural vs Coronary Alignment to Avoid Coronary Overlap With THV-Commissure in TAVR

Manish Vinayak, Gilbert H L Tang, Keva Li, Megan Berdan, Anoop N Koshy, Sahil Khera, Stamatios Lerakis, George D Dangas, Samin K Sharma, Annapoorna S Kini, Parasuram Krishnamoorthy

JACC: Cardiovascular Interventions · 2024-03 · 17 (6) · 715-726

DOI: 10.1016/j.jcin.2024.01.073 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JACC: Cardiovascular Interventions, 2024-03. Verfasst von Manish Vinayak und 10 weiteren Autor:innen. Beteiligte Einrichtung: Mount Sinai Heart, Mount Sinai Hospital, New York, New York, USA. Electronic address: https://twitter.com/manishvinayak. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Heart Valve Prosthesis. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 18 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Coronary alignment is proposed as an alternative to commissural alignment for reducing coronary overlap during transcatheter aortic valve replacement (TAVR). However, largescale studies are lacking. OBJECTIVES: This study aimed to determine the incidence of coronary overlap with commissural vs coronary alignment using computed tomography (CT) simulation in patients undergoing TAVR evaluation. METHODS: In 1,851 CT scans of native aortic stenosis patients undergoing TAVR evaluation (April 2018 to December 2022),virtual valves simulating commissural and coronary alignment were superimposed on axial aortic root images. Coronary overlap was assessed based on the angular gap between coronary artery origin and the nearest transcatheter heart valve commissure, categorized as severe (≤15°), moderate (15°-30°), mild (30°-45°), and no-overlap (45°-60°). RESULTS: The overall incidence of moderate/severe and severe overlap with either coronary artery remained rare with either coronary or commissural alignment (coronary 0.52% left, 0.52% right; commissural 0.30% left, 3.27% right). Comparing techniques, coronary alignment reduced moderate/severe overlap only for the right coronary artery (0.38% vs 2.97%; P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Transcatheter Aortic Valve ReplacementHeart Valve ProsthesisHumansAortic ValveTreatment OutcomeMultidetector Computed Tomography

Stichwörter der Autor:innen

TAVRcommissural alignmentcoronary alignment

Autor:innen und Institutionen

  • Mount Sinai Heart, Mount Sinai Hospital, New York, New York, USA. Electronic address: https://twitter.com/manishvinayak.
  • Department of Cardiovascular Surgery, Mount Sinai Health System, New York, New York, USA. Electronic address: gilbert.tang@mountsinai.org.
  • Department of Cardiovascular Surgery, Mount Sinai Health System, New York, New York, USA.
  • Mount Sinai Heart, Mount Sinai Hospital, New York, New York, USA; The Royal Melbourne Hospital & The University of Melbourne, Victoria, Australia. Electronic address: https://twitter.com/DrAnoop_Koshy.
  • Mount Sinai Heart, Mount Sinai Hospital, New York, New York, USA. Electronic address: https://twitter.com/Khera_MD.
  • Mount Sinai Heart, Mount Sinai Hospital, New York, New York, USA.

Zitieren

APA

Vinayak, M., Tang, G. H. L., Li, K., Berdan, M., Koshy, A. N., Khera, S., Lerakis, S., Dangas, G. D., Sharma, S. K., Kini, A. S., & Krishnamoorthy, P. (2024). Commissural vs Coronary Alignment to Avoid Coronary Overlap With THV-Commissure in TAVR. JACC: Cardiovascular Interventions, 17(6), 715-726. https://doi.org/10.1016/j.jcin.2024.01.073

Vancouver

Vinayak M, Tang GHL, Li K, Berdan M, Koshy AN, Khera S, et al. Commissural vs Coronary Alignment to Avoid Coronary Overlap With THV-Commissure in TAVR. JACC: Cardiovascular Interventions. 2024;17(6):715-726. doi:10.1016/j.jcin.2024.01.073

BibTeX
@article{Vinayak2024,
  author = {Vinayak, Manish and Tang, Gilbert H L and Li, Keva and Berdan, Megan and Koshy, Anoop N and Khera, Sahil and Lerakis, Stamatios and Dangas, George D and Sharma, Samin K and Kini, Annapoorna S and Krishnamoorthy, Parasuram},
  title = {Commissural vs Coronary Alignment to Avoid Coronary Overlap With THV-Commissure in TAVR},
  journal = {JACC: Cardiovascular Interventions},
  year = {2024},
  volume = {17},
  number = {6},
  pages = {715--726},
  doi = {10.1016/j.jcin.2024.01.073}
}
Kostenlos starten →