Chimney Stenting vs BASILICA for Prevention of Acute Coronary Obstruction During Transcatheter Aortic Valve Replacement
JACC: Cardiovascular Interventions · 2024-03 · 17 (6) · 742-752
DOI: 10.1016/j.jcin.2024.01.007 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift JACC: Cardiovascular Interventions, 2024-03. Verfasst von Antonio Mangieri und 20 weiteren Autor:innen. Beteiligte Einrichtung: IRCCS Humanitas Research Hospital, Rozzano-Milan, Italy. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Lacerations, Heart Valve Prosthesis, Coronary Occlusion. Die Arbeit wurde bisher 52-mal zitiert (Crossref) und nennt 19 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Coronary obstruction (CO) is a potentially life-threatening complication of transcatheter aortic valve replacement (TAVR). Chimney stenting or leaflet laceration with transcatheter electrosurgery (Bioprosthetic or Native Aortic Scallop Intentional Laceration to Prevent Iatrogenic Coronary Artery Obstruction [BASILICA]) are 2 techniques developed to prevent CO. OBJECTIVES: The aim of the present study was to compare periprocedural and 1-year outcomes of chimney and BASILICA in TAVR patients at high risk of CO. METHODS: This multicenter observational registry enrolled consecutive TAVR patients at high risk of CO, undergoing either preventive chimney stenting or BASILICA. Clinical success was defined as successful performance of the chimney or BASILICA technique without clinically relevant ostial CO. The primary endpoint was major adverse cardiovascular events, a composite of death, myocardial infarction, stroke, or unplanned target lesion coronary revascularization at 1 year. RESULTS: A total of 168 patients were included: 71 (42.3%) received chimney stenting, and 97 (57.7%) underwent BASILICA. Patients undergoing BASILICA had higher preprocedural risk of CO, as indicated by lower sinotubular junction height (18.2 ± 4.8 mm vs 14.8 ± 3.4 mm; P < 0.001) and diameter (28.2 ± 4.5 vs 26.8 ± 3.4; P = 0.029). Rates of periprocedural complications were similar between the 2 groups. Clinical success was 97.2% and 96.9% in chimney and BASILICA, respectively (P = 0.92). At 1-year follow-up, the cumulative incidence of major adverse cardiovascular events was 18.7% (95% CI: 11%-30.6%) in the chimney group and 19.9% (95% CI: 12.1%-31.5%) in the BASILICA group (log-rank P = 0.848), whereas chimney was associated with a numerically higher cardiovascular mortality than BASILICA (6.7% vs 1.3%; log-rank P = 0.168). CONCLUSIONS: Chimney stenting and BASILICA effectively prevent TAVR-induced acute CO. Both techniques seem to have comparable acceptable periprocedural and 1-year outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- IRCCS Humanitas Research Hospital, Rozzano-Milan, Italy.
- Department of Cardiology, Heart Centre Leipzig at University of Leipzig, Leipzig, Germany.
- IRCCS Humanitas Research Hospital, Rozzano-Milan, Italy; Department of Biomedical Sciences, Humanitas University, Pieve Emanuele-Milan, Italy.
- Department of Cardiology, IRCCS Policlinico San Donato, Milan, Italy.
- Department of Cardiology, Swiss Cardiovascular Centre, Bern University Hospital, Bern, Switzerland.
- School of Medicine, Vita-Salute San Raffaele University, Milan, Italy; Interventional Cardiology Unit IRCCS San Raffaele Scientific Institute, Milan, Italy.
Zitieren
APA
Mangieri, A., Richter, I., Gitto, M., Abdelhafez, A., Bedogni, F., Lanz, J., Montorfano, M., Unbehaun, A., Giannini, F., Nerla, R., Taramasso, M., Ielasi, A., Rudolph, T., Ferlini, M., Ribichini, F., Poletti, E., Latib, A., Colombo, A., Van Mieghem, N. M., …, & Abdel-Wahab, M. (2024). Chimney Stenting vs BASILICA for Prevention of Acute Coronary Obstruction During Transcatheter Aortic Valve Replacement. JACC: Cardiovascular Interventions, 17(6), 742-752. https://doi.org/10.1016/j.jcin.2024.01.007
Vancouver
Mangieri A, Richter I, Gitto M, Abdelhafez A, Bedogni F, Lanz J, et al. Chimney Stenting vs BASILICA for Prevention of Acute Coronary Obstruction During Transcatheter Aortic Valve Replacement. JACC: Cardiovascular Interventions. 2024;17(6):742-752. doi:10.1016/j.jcin.2024.01.007
BibTeX
@article{Mangieri2024,
author = {Mangieri, Antonio and Richter, Ines and Gitto, Mauro and Abdelhafez, Ahmed and Bedogni, Francesco and Lanz, Jonas and Montorfano, Matteo and Unbehaun, Axel and Giannini, Francesco and Nerla, Roberto and Taramasso, Maurizio and Ielasi, Alfonso and Rudolph, Tanja and Ferlini, Marco and Ribichini, Flavio and Poletti, Enrico and Latib, Azeem and Colombo, Antonio and Van Mieghem, Nicolas M and Thiele, Holger and Abdel-Wahab, Mohamed},
title = {Chimney Stenting vs BASILICA for Prevention of Acute Coronary Obstruction During Transcatheter Aortic Valve Replacement},
journal = {JACC: Cardiovascular Interventions},
year = {2024},
volume = {17},
number = {6},
pages = {742--752},
doi = {10.1016/j.jcin.2024.01.007}
}
EUVIMED