Anonymous Comparison of Various Angiography-Derived Fractional Flow Reserve Software With Pressure-Derived Physiological Assessment
JACC: Cardiovascular Interventions · 2023-07 · 16 (14) · 1778-1790
DOI: 10.1016/j.jcin.2023.04.026 ↗Kurz gefasst
Fachartikel in der Zeitschrift JACC: Cardiovascular Interventions, 2023-07. Verfasst von Kai Ninomiya und 17 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, National University of Ireland, Galway, Galway, Ireland. Hauptthemen laut MEDLINE: Fractional Flow Reserve, Myocardial, Coronary Stenosis. Die Arbeit wurde bisher 70-mal zitiert (Crossref) und nennt 27 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Software to compute angiography-derived fractional flow reserve (angio-FFR) have been validated against pressure wire-derived fractional flow reserve (PW-FFR) with an area under the receiver-operating characteristic curve (AUC) of 0.93 to 0.97. OBJECTIVES: The aim of this study was to investigate diagnostic accuracies of 5 angio-FFR software/methods by an independent core lab in a prospective cohort of 390 vessels with carefully documented sites of PW-FFR and pressure wire-derived instantaneous wave-free ratio. METHODS: One "matcher investigator" colocalized on angiography the sites of pressure wire measurement with angio-FFR measurements and provided the same 2 optimal angiographic views and frame selection to independent analysts who were blinded to invasive physiological results and results from other software. The results were anonymized and randomly presented. The AUC of each angio-FFR was compared with 2-dimensional quantitative coronary angiography (QCA) percent diameter stenosis (%DS) using a 2-tailed paired comparison of AUC. RESULTS: All 5 software/methods yielded a high proportion of analyzable vessels (A: 100%, B: 100%, C: 92.1%, D: 99.5%, and E: 92.1%). The AUCs for predicting fractional flow reserve ≤0.8 for software A, B, C, D, E, and 2-dimensional QCA %DS were 0.75, 0.74, 0.74, 0.73, 0.73, and 0.65, respectively. The AUC for each angio-FFR was significantly greater than that for 2-dimensional QCA %DS. CONCLUSIONS: This head-to-head comparison by an independent core lab demonstrated that the diagnostic accuracy of various angio-FFR software for predicting PW-FFR ≤0.80 was useful, with a higher discrimination compared with 2-dimensional QCA %DS; however, it did not reach the diagnostic accuracy previously reported in validation studies of various vendors. Therefore, the intrinsic clinical value of "angiography-derived fractional flow reserve" requires confirmation in large clinical trials.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, National University of Ireland, Galway, Galway, Ireland.
- Department of Cardiology, National University of Ireland, Galway, Galway, Ireland; National Heart and Lung Institute, Imperial College London, London, United Kingdom. Electronic address: patrick.serruys@nuigalway.ie.
- Department of Cardiology, Royal Blackburn Hospital, Blackburn, United Kingdom.
- Department of Cardiovascular Medicine, Wakayama Medical University, Wakayama, Japan.
- Hospital Clínico San Carlos Instituto de Investigación Sanitaria San Carlos, Universidad Complutense de Madrid, Madrid, Spain.
- Division of Cardiology and Duke Clinical Research Institute, Duke University, Durham, North Carolina, USA.
Zitieren
APA
Ninomiya, K., Serruys, P. W., Kotoku, N., Zhou, J., Kageyama, S., Masuda, S., Revaiah, P. C., Wang, B., He, X., Tsai, T. Y., Kageyama, M., Sevestre, E., Sharif, F., Garg, S., Akasaka, T., Escaned, J., Patel, M. R., & Onuma, Y. (2023). Anonymous Comparison of Various Angiography-Derived Fractional Flow Reserve Software With Pressure-Derived Physiological Assessment. JACC: Cardiovascular Interventions, 16(14), 1778-1790. https://doi.org/10.1016/j.jcin.2023.04.026
Vancouver
Ninomiya K, Serruys PW, Kotoku N, Zhou J, Kageyama S, Masuda S, et al. Anonymous Comparison of Various Angiography-Derived Fractional Flow Reserve Software With Pressure-Derived Physiological Assessment. JACC: Cardiovascular Interventions. 2023;16(14):1778-1790. doi:10.1016/j.jcin.2023.04.026
BibTeX
@article{Ninomiya2023,
author = {Ninomiya, Kai and Serruys, Patrick W and Kotoku, Nozomi and Zhou, Jinying and Kageyama, Shigetaka and Masuda, Shinichiro and Revaiah, Pruthvi C and Wang, Bo and He, Xingqiang and Tsai, Tsung-Ying and Kageyama, Momoko and Sevestre, Emelyne and Sharif, Faisal and Garg, Scot and Akasaka, Takashi and Escaned, Javier and Patel, Manesh R and Onuma, Yoshinobu},
title = {Anonymous Comparison of Various Angiography-Derived Fractional Flow Reserve Software With Pressure-Derived Physiological Assessment},
journal = {JACC: Cardiovascular Interventions},
year = {2023},
volume = {16},
number = {14},
pages = {1778--1790},
doi = {10.1016/j.jcin.2023.04.026}
}
EUVIMED