Systematische Übersicht in der Zeitschrift JACC: Cardiovascular Interventions, 2023-04. Verfasst von Nishant Jain und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine, University of Michigan, Ann Arbor, Michigan, USA. Hauptthemen laut MEDLINE: Hypertension, Pulmonary, Pulmonary Embolism, Lung Injury, Vascular System Injuries. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS, University of Michigan.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Balloon pulmonary angioplasty (BPA) was introduced as a treatment modality for patients with inoperable, medically refractory chronic thromboembolic pulmonary hypertension decades ago; however, reports of high rates of pulmonary vascular injury have led to considerable refinement in procedural technique. OBJECTIVES: The authors sought to better understand the evolution of BPA procedure-related complications over time. METHODS: The authors conducted a systematic review of original articles published by pulmonary hypertension centers globally and performed a pooled cohort analysis of procedure-related outcomes with BPA. RESULTS: This systematic review identified 26 published articles from 18 countries worldwide from 2013 to 2022. A total of 1,714 patients underwent 7,561 total BPA procedures with an average follow up of 7.3 months. From the first period (2013-2017) to the second period (2018-2022), the cumulative incidence of hemoptysis/vascular injury decreased from 14.1% (474/3,351) to 7.7% (233/3,029) (P < 0.01); lung injury/reperfusion edema decreased from 11.3% (377/3,351) to 1.4% (57/3,943) (P < 0.01); invasive mechanical ventilation decreased from 0.7% (23/3,195) to 0.1% (4/3,062) (P < 0.01); and mortality decreased from 2.0% (13/636) to 0.8% (8/1,071) (P < 0.01). CONCLUSIONS: Procedure-related complications with BPA, including hemoptysis/vascular injury, lung injury/reperfusion edema, mechanical ventilation, and death, were less common in the second period (2018-2022), compared with first period (2013-2017), likely from refinement in patient and lesion selection and procedural technique over time.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hypertension, PulmonaryPulmonary EmbolismLung InjuryVascular System InjuriesAngioplasty, BalloonPulmonary EdemaHumansPulmonary ArteryHemoptysisTreatment OutcomeEdemaChronic Disease

Stichwörter der Autor:innen

balloon pulmonary angioplastychronic thromboembolic pulmonary hypertensionpulmonary artery angioplasty

Autor:innen und Institutionen

  • Department of Internal Medicine, University of Michigan, Ann Arbor, Michigan, USA.
  • Division of Cardiology, Department of Internal Medicine, Southern Illinois University School of Medicine, Springfield, Illinois, USA.
  • Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Medical College of Wisconsin, Milwaukee, Wisconsin, USA.
  • University of Michigan Taubman Health Sciences Library, Ann Arbor, Michigan, USA.
  • Division of Cardiology, Duke University Medical Center, Durham, North Carolina, USA.
  • Smith Center for Outcomes Research in Cardiology, Division of Cardiology, Department of Medicine (E.A.S.), Beth Israel Deaconess Medical Center, Boston, Massachusetts, USA.

Förderung

  • NHLBI NIH HHS
  • University of Michigan

Zitieren

APA

Jain, N., Sheikh, M. A., Bajaj, D., Townsend, W., Krasuski, R., Secemsky, E., Chatterjee, S., Moles, V., Agarwal, P. P., Haft, J., Visovatti, S. H., Cascino, T. M., Rosenfield, K., Nallamothu, B. K., Mclaughlin, V. V., & Aggarwal, V. (2023). Periprocedural Complications With Balloon Pulmonary Angioplasty. JACC: Cardiovascular Interventions, 16(8), 976-983. https://doi.org/10.1016/j.jcin.2023.01.361

Vancouver

Jain N, Sheikh MA, Bajaj D, Townsend W, Krasuski R, Secemsky E, et al. Periprocedural Complications With Balloon Pulmonary Angioplasty. JACC: Cardiovascular Interventions. 2023;16(8):976-983. doi:10.1016/j.jcin.2023.01.361

BibTeX
@article{Jain2023,
  author = {Jain, Nishant and Sheikh, Muhammad A and Bajaj, Divyansh and Townsend, Whitney and Krasuski, Richard and Secemsky, Eric and Chatterjee, Saurav and Moles, Victor and Agarwal, Prachi P and Haft, Jonathan and Visovatti, Scott H and Cascino, Thomas M and Rosenfield, Kenneth and Nallamothu, Brahmajee K and Mclaughlin, Vallerie V and Aggarwal, Vikas},
  title = {Periprocedural Complications With Balloon Pulmonary Angioplasty},
  journal = {JACC: Cardiovascular Interventions},
  year = {2023},
  volume = {16},
  number = {8},
  pages = {976--983},
  doi = {10.1016/j.jcin.2023.01.361}
}
Kostenlos starten →