EUVIMEDEUVIMED entdecken
Crossref

Identification of endogenous carbonyl steroids in human serum by chemical derivatization, hydrogen/deuterium exchange mass spectrometry and the quantitative structure-retention relationship

Yinyu Wei, Yi Sun, Shuailong Jia, Pan Yan, Chaomei Xiong, Meiling Qi, Chenxi Wang, Zhifeng Du, Hongliang Jiang

Journal of Chromatography B · 2023

DOI: 10.1016/j.jchromb.2023.123776 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Chromatography B, 2023. Verfasst von Yinyu Wei und 8 weiteren Autor:innen. Beteiligte Einrichtung: Tongji School of Pharmacy, Huazhong University of Science and Technology, Wuhan 430030, China. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Steroids. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 55 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Steroids are tetracyclic aliphatic compounds, and most of them contain carbonyl groups. The disordered homeostasis of steroids is closely related to the occurrence and progression of various diseases. Due to high structural similarity, low concentrations in vivo, poor ionization efficiency, and interference from endogenous substances, it is very challenging to comprehensively and unambiguously identify endogenous steroids in biological matrix. Herein, an integrated strategy was developed for the characterization of endogenous steroids in serum based on chemical derivatization, ultra-performance liquid chromatography quadrupole Exactive mass spectrometry (UPLC-Q-Exactive-MS/MS), hydrogen/deuterium (H/D) exchange, and a quantitative structure-retention relationship (QSRR) model. To enhance the mass spectrometry (MS) response of carbonyl steroids, the ketonic carbonyl group was derivatized by Girard T (GT). Firstly, the fragmentation rules of derivatized carbonyl steroid standards by GT were summarized. Then, carbonyl steroids in serum were derivatized by GT and identified based on the fragmentation rules or by comparing retention time and MS/MS spectra with those of standards. H/D exchange MS was utilized to distinguish derivatized steroid isomers for the first time. Finally, a QSRR model was constructed to predict the retention time of the unknown steroid derivatives. With this strategy, 93 carbonyl steroids were identified from human serum, and 30 of them were determined to be dicarbonyl steroids by the charge number of characteristic ions and the number of exchangeable hrdrogen or comparing with standards. The QSRR model built by the machine learning algorithms has an excellent regression correlation, thus the accurate structures of 14 carbonyl steroids were determined, among which three steroids were reported for the first time in human serum. This study provides a new analytical method for the comprehensive and reliable identification of carbonyl steroids in biological matrix.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometrySteroidsHumansDeuteriumChromatography, High Pressure LiquidChromatography, Liquid

Stichwörter der Autor:innen

Carbonyl steroidsDerivatizationH/D exchangeQuantitative structure-retention relationshipUPLC-Q-exactive-MS/MS

Substanzen

DeuteriumSteroids

Autor:innen und Institutionen

  • Tongji School of Pharmacy, Huazhong University of Science and Technology, Wuhan 430030, China.
  • Department of Pharmacy, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 430030 Wuhan, China.
  • Department of Pharmacy, The Affiliated Changsha Central Hospital, Hengyang Medical School, University of South China, Changsha 410028, China.
  • Tongji School of Pharmacy, Huazhong University of Science and Technology, Wuhan 430030, China. Electronic address: duzhifeng@hust.edu.cn.
  • Tongji School of Pharmacy, Huazhong University of Science and Technology, Wuhan 430030, China. Electronic address: jianghongliang@hust.edu.cn.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Wei, Y., Sun, Y., Jia, S., Yan, P., Xiong, C., Qi, M., Wang, C., Du, Z., & Jiang, H. (2023). Identification of endogenous carbonyl steroids in human serum by chemical derivatization, hydrogen/deuterium exchange mass spectrometry and the quantitative structure-retention relationship. Journal of Chromatography B. https://doi.org/10.1016/j.jchromb.2023.123776

Vancouver

Wei Y, Sun Y, Jia S, Yan P, Xiong C, Qi M, et al. Identification of endogenous carbonyl steroids in human serum by chemical derivatization, hydrogen/deuterium exchange mass spectrometry and the quantitative structure-retention relationship. Journal of Chromatography B. 2023. doi:10.1016/j.jchromb.2023.123776

BibTeX
@article{Wei2023,
  author = {Wei, Yinyu and Sun, Yi and Jia, Shuailong and Yan, Pan and Xiong, Chaomei and Qi, Meiling and Wang, Chenxi and Du, Zhifeng and Jiang, Hongliang},
  title = {Identification of endogenous carbonyl steroids in human serum by chemical derivatization, hydrogen/deuterium exchange mass spectrometry and the quantitative structure-retention relationship},
  journal = {Journal of Chromatography B},
  year = {2023},
  doi = {10.1016/j.jchromb.2023.123776}
}
Kostenlos starten →