EUVIMEDEUVIMED entdecken
Beobachtungsstudie

Cardiopulmonary Performance Among Heart Failure Patients Before and After Left Ventricular Assist Device Implantation

Cole Buchanan, Collen Buchanan, Maeveen Riordan, Jessica Byrd, Margaret Schulte, Wendy M Kohrt, Amrut V Ambardekar, Larry A Allen, Gene Wolfel, Justin Lawley, Benjamin D Levine, William K Cornwell

JACC: Heart Failure · 2024

DOI: 10.1016/j.jchf.2023.06.017 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift JACC: Heart Failure, 2024. Verfasst von Cole Buchanan und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA. Hauptthemen laut MEDLINE: Heart Failure, Heart-Assist Devices, Ventricular Dysfunction, Left. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: NHLBI NIH HHS, NCATS NIH HHS, NIH.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Patients with heart failure with reduced ejection fraction (HFrEF) have persistent impairments in functional capacity after continuous-flow left ventricular assist device (CF-LVAD) implantation. OBJECTIVES: This study aims to characterize longitudinal changes in exercise hemodynamics and functional capacity among patients with HFrEF before and after CF-LVAD implantation. METHODS: Ten patients underwent 3 invasive cardiopulmonary exercise tests on upright cycle ergometry with pulmonary artery catheterization: 1) Visit 1 before CF-LVAD implantation; 2) Visit 2 after device implantation with CF-LVAD pump speed held constant at baseline speed; and 3) Visit 3 with increases in pump speed during exercise (median: 1,050 rpm [IQR: 750-1,150 rpm] and 220 rpm [IQR: 120-220 rpm] for HeartMate 3 and HeartWare VAD, respectively). Hemodynamics and direct Fick cardiac output were monitored using pulmonary artery catheterization. Gas exchange metrics were determined using indirect calorimetry. RESULTS: Maximal oxygen uptake (Visits 1, 2, and 3: 10.8 ± 2.5 mL/kg/min, 10.7 ± 2.2 mL/kg/min, and 11.5 ± 1.7 mL/kg/min; P = 0.92) did not improve after device implantation. Mean pulmonary arterial and pulmonary capillary wedge pressures increased significantly during submaximal and peak exercise on preimplantation testing (P < 0.01 for rest vs peak exercise) and remained elevated, with minimal change on Visits 2 and 3 regardless of whether pump speed was fixed or increased. CONCLUSIONS: Among patients with HFrEF, cardiovascular hemodynamics and exercise capacity were similar after CF-LVAD implantation, regardless of whether patients exercised at fixed or adjusted pump speeds during exercise. Further research is needed to determine methods by which LVADs may alleviate the HFrEF syndrome after device implantation. (Effect of mechanIcal circulatoRy support ON exercise capacity aMong pAtieNts with heart failure [IRONMAN]; NCT03078972).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart FailureHeart-Assist DevicesVentricular Dysfunction, LeftHumansCardiac OutputExercise TestHemodynamicsStroke VolumeVentricular Function, Left

Stichwörter der Autor:innen

exerciseheart failure with reduced ejection fractionhemodynamicsleft ventricular assist device

Autor:innen und Institutionen

  • Department of Internal Medicine, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA.
  • Department of Medicine-Cardiology, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA.
  • Colorado Clinical and Translational Sciences Institute, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA.
  • Colorado Clinical and Translational Sciences Institute, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA; Department of Medicine-Geriatric Medicine, University of Colorado Anschutz Medical Campus, A…
  • Department of Sport Science, Division of Physiology, University of Innsbruck, Innsbruck, Austria.
  • Department of Medicine, Division of Cardiology, University of Texas Southwestern Medical Center, and the Institute for Exercise and Environmental Medicine, Texas Health Presbyterian Dallas, Dallas, Texas, USA.

Förderung

  • NHLBI NIH HHS
  • NCATS NIH HHS
  • NIH

Zitieren

APA

Buchanan, C., Buchanan, C., Riordan, M., Byrd, J., Schulte, M., Kohrt, W. M., Ambardekar, A. V., Allen, L. A., Wolfel, G., Lawley, J., Levine, B. D., & Cornwell, W. K. (2024). Cardiopulmonary Performance Among Heart Failure Patients Before and After Left Ventricular Assist Device Implantation. JACC: Heart Failure. https://doi.org/10.1016/j.jchf.2023.06.017

Vancouver

Buchanan C, Buchanan C, Riordan M, Byrd J, Schulte M, Kohrt WM, et al. Cardiopulmonary Performance Among Heart Failure Patients Before and After Left Ventricular Assist Device Implantation. JACC: Heart Failure. 2024. doi:10.1016/j.jchf.2023.06.017

BibTeX
@article{Buchanan2024,
  author = {Buchanan, Cole and Buchanan, Collen and Riordan, Maeveen and Byrd, Jessica and Schulte, Margaret and Kohrt, Wendy M and Ambardekar, Amrut V and Allen, Larry A and Wolfel, Gene and Lawley, Justin and Levine, Benjamin D and Cornwell, William K},
  title = {Cardiopulmonary Performance Among Heart Failure Patients Before and After Left Ventricular Assist Device Implantation},
  journal = {JACC: Heart Failure},
  year = {2024},
  doi = {10.1016/j.jchf.2023.06.017}
}
Kostenlos starten →