Computed tomography anatomic predictors of outcomes in patients undergoing tricuspid transcatheter edge-to-edge repair
Journal of Cardiovascular Computed Tomography · 2024-05 · 18 (3) · 259-266
DOI: 10.1016/j.jcct.2024.02.001 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Cardiovascular Computed Tomography, 2024-05. Verfasst von Joanna Bartkowiak und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, The NewYork-Presbyterian/Columbia University Irving Medical Center, New York, NY, USA; Graduate School for Health Sciences, U…. Hauptthemen laut MEDLINE: Tricuspid Valve, Tricuspid Valve Insufficiency, Predictive Value of Tests, Cardiac Catheterization. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
AIM: To identify anatomical computed tomography (CT) predictors of procedural and clinical outcomes in patients undergoing tricuspid transcatheter edge-to-edge repair (T-TEER). METHODS AND RESULTS: Consecutive patients undergoing T-TEER between March 2018 to December 2022 who had cardiac CT prior to the procedure were included. CT scans were automatically analyzed using a dedicated software that employs deep learning techniques to provide precise anatomical measurements and volumetric calculations. Technical success was defined as successful placement of at least one implant in the planned anatomic location without single leaflet device attachment. Procedural success was defined as tricuspid regurgitation reduction to moderate or less. Procedural complexity was assessed by measuring the fluoroscopy time. The clinical endpoint was a composite of death, heart failure hospitalization, or tricuspid re-intervention throughout two years. A total of 33 patients (63.6% male) were included. Procedural success was achieved in 22 patients (66.7%). Shorter end-systolic (ES) height between the inferior vena cava (IVC) and tricuspid annulus (TA) (r = - 0.398, p = 0.044) and longer ES RV length (r = 0.551, p = 0.006) correlated with higher procedural complexity. ES RV length was independently associated with lower technical(adjusted Odds ratio [OR] 0.812 [95% CI 0.665-0.991], p = 0.040) and procedural success (adjusted OR 0.766, CI [0.591-0.992], p = 0.043). Patients with ES right ventricular (RV) length of >77.4 mm had a four-fold increased risk of experiencing the composite clinical endpoint compared to patients with ES RV length ≤77.4 mm (HR = 3.964 [95% CI, 1.018-15.434]; p = 0,034]). CONCLUSION: CT-derived RV length and IVC-to-TA height may be helpful to identify patients at increased risk for procedural complexity and adverse outcomes when undergoing T-TEER. CT provides valuable information for preprocedural decision-making and device selection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Medicine, The NewYork-Presbyterian/Columbia University Irving Medical Center, New York, NY, USA; Graduate School for Health Sciences, University of Bern, Bern, Switzerland.
- Department of Cardiology, University and Hospital of Fribourg, Fribourg, Switzerland; Arrhythmia Services, Division of Cardiology, Department of Medicine, McMaster University, Hamilton, Ontario, Canada; Department of Ca…
- Department of Cardiology, University of Bern, Inselspital, Bern, Switzerland.
- Department of Medicine, The NewYork-Presbyterian/Columbia University Irving Medical Center, New York, NY, USA.
- Department of Cardiology, University of Bern, Inselspital, Bern, Switzerland. Electronic address: fabien.praz@insel.ch.
Zitieren
APA
Bartkowiak, J., Vivekanantham, H., Kassar, M., Dernektsi, C., Agarwal, V., Lebehn, M., Windecker, S., Brugger, N., Hahn, R. T., & Praz, F. (2024). Computed tomography anatomic predictors of outcomes in patients undergoing tricuspid transcatheter edge-to-edge repair. Journal of Cardiovascular Computed Tomography, 18(3), 259-266. https://doi.org/10.1016/j.jcct.2024.02.001
Vancouver
Bartkowiak J, Vivekanantham H, Kassar M, Dernektsi C, Agarwal V, Lebehn M, et al. Computed tomography anatomic predictors of outcomes in patients undergoing tricuspid transcatheter edge-to-edge repair. Journal of Cardiovascular Computed Tomography. 2024;18(3):259-266. doi:10.1016/j.jcct.2024.02.001
BibTeX
@article{Bartkowiak2024,
author = {Bartkowiak, Joanna and Vivekanantham, Hari and Kassar, Mohammad and Dernektsi, Chrisoula and Agarwal, Vratika and Lebehn, Mark and Windecker, Stephan and Brugger, Nicolas and Hahn, Rebecca T and Praz, Fabien},
title = {Computed tomography anatomic predictors of outcomes in patients undergoing tricuspid transcatheter edge-to-edge repair},
journal = {Journal of Cardiovascular Computed Tomography},
year = {2024},
volume = {18},
number = {3},
pages = {259--266},
doi = {10.1016/j.jcct.2024.02.001}
}