Optimal diagnostic approach for using CT-derived quantitative flow ratio in patients with stenosis on coronary computed tomography angiography
Journal of Cardiovascular Computed Tomography · 2024
DOI: 10.1016/j.jcct.2024.01.004 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Cardiovascular Computed Tomography, 2024. Verfasst von Jonathan N Dahl und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Gødstrup Hospital, Herning, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark. Electronic addres…. Hauptthemen laut MEDLINE: Coronary Stenosis, Fractional Flow Reserve, Myocardial, Coronary Artery Disease. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science Foundation Ireland, Novo Nordisk Fonden, Hjerteforeningen.
Abstract (Originalsprache)
BACKGROUND: Coronary computed tomography angiography (CCTA)-derived quantitative flow ratio (CT-QFR) is an on-site non-invasive technique estimating invasive fractional flow reserve (FFR). This study assesses the diagnostic performance of using most distal CT-QFR versus lesion-specific CT-QFR approach for identifying hemodynamically obstructive coronary artery disease (CAD). METHODS: Prospectively enrolled de novo chest pain patients (n = 445) with ≥50 % visual diameter stenosis on CCTA were referred for invasive evaluation. On-site CT-QFR was analyzed post-hoc blinded to angiographic data and obtained as both most distal (MD-QFR) and lesion-specific CT-QFR (LS-QFR). Abnormal CT-QFR was defined as ≤0.80. Hemodynamically obstructive CAD was defined as invasive FFR ≤0.80 or ≥70 % diameter stenosis by 3D-quantitative coronary angiography. RESULTS: In total 404/445 patients had paired CT-QFR and invasive analyses of whom 149/404 (37 %) had hemodynamically obstructive CAD. MD-QFR and LS-QFR classified 188 (47 %) and 165 (41 %) patients as abnormal, respectively. Areas under the receiver-operating characteristic curve for MD-QFR was 0.83 vs. 0.85 for LS-QFR, p = 0.01. Sensitivities for MD-QFR and LS-QFR were 80 % (95%CI: 73-86) vs. 77 % (95%CI: 69-83), p = 0.03, respectively, and specificities were 73 % (95%CI: 67-78) vs. 80 % (95%CI: 75-85), p < 0.01, respectively. Positive predictive values for MD-QFR and LS-QFR were 63 % vs. 69 %, p < 0.01, respectively, and negative predictive values for MD-QFR and LS-QFR were 86 % vs. 85 %, p = 0.39, respectively). CONCLUSION: Using a lesion-specific CT-QFR approach has superior discrimination of hemodynamically obstructive CAD compared to a most distal CT-QFR approach. CT-QFR identified most cases of hemodynamically obstructive CAD while a normal CT-QFR excluded hemodynamically obstructive CAD in the majority of patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Gødstrup Hospital, Herning, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark. Electronic address: jonadh@rm.dk.
- Department of Cardiology, Gødstrup Hospital, Herning, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark; Department of Cardiology, Aalborg University Hospital, Aalborg, Denmark. Electronic add…
- The Lambe Institute for Translational Research and Curam, University of Galway, Ireland; Biomedical Instrument Institute, School of Biomedical Engineering, Shanghai Jiao Tong University, China. Electronic address: d.din…
- Biomedical Instrument Institute, School of Biomedical Engineering, Shanghai Jiao Tong University, China; Med-X Research Institute, Shanghai Jiao Tong University, Shanghai, China. Electronic address: sxtu@sjtu.edu.cn.
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark; Department of Cardiology, Aarhus University Hospital, Denmark. Electronic address: jelwes@rm.dk.
- The Lambe Institute for Translational Research and Curam, University of Galway, Ireland. Electronic address: william.wyns@nuigalway.ie.
Förderung
- Science Foundation Ireland
- Novo Nordisk Fonden
- Hjerteforeningen
Zitieren
APA
Dahl, J. N., Rasmussen, L. D., Ding, D., Tu, S., Westra, J., Wijns, W., Christiansen, E. H., Eftekhari, A., Li, G., Winther, S., & Bøttcher, M. (2024). Optimal diagnostic approach for using CT-derived quantitative flow ratio in patients with stenosis on coronary computed tomography angiography. Journal of Cardiovascular Computed Tomography. https://doi.org/10.1016/j.jcct.2024.01.004
Vancouver
Dahl JN, Rasmussen LD, Ding D, Tu S, Westra J, Wijns W, et al. Optimal diagnostic approach for using CT-derived quantitative flow ratio in patients with stenosis on coronary computed tomography angiography. Journal of Cardiovascular Computed Tomography. 2024. doi:10.1016/j.jcct.2024.01.004
BibTeX
@article{Dahl2024,
author = {Dahl, Jonathan N and Rasmussen, Laust D and Ding, Daixin and Tu, Shengxian and Westra, Jelmer and Wijns, William and Christiansen, Evald Høj and Eftekhari, Ashkan and Li, Guanyu and Winther, Simon and Bøttcher, Morten},
title = {Optimal diagnostic approach for using CT-derived quantitative flow ratio in patients with stenosis on coronary computed tomography angiography},
journal = {Journal of Cardiovascular Computed Tomography},
year = {2024},
doi = {10.1016/j.jcct.2024.01.004}
}
EUVIMED