Ultra-high-resolution spectral silicon-based photon-counting detector CT for coronary CT angiography: Initial results in a dynamic phantom
Journal of Cardiovascular Computed Tomography · 2023-09 · 17 (5) · 341-344
DOI: 10.1016/j.jcct.2023.08.003 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Cardiovascular Computed Tomography, 2023-09. Verfasst von Thomas Wesley Holmes und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Imaging Sciences, Emory University, 1364 Clifton Road NE, Atlanta, GA 30322, USA. Hauptthemen laut MEDLINE: Computed Tomography Angiography, Silicon. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 15 Literaturangaben. Gefördert von: Emory University, GE Healthcare.
Abstract (Originalsprache)
BACKGROUND: Recent improvements in CT detector technology have led to smaller detector pixels resolving frequencies beyond 20 lp/cm and enabled ultra-high-resolution CT. Silicon-based photon-counting detector (PCD) CT is one such technology that promises improved spatial and spectral resolution. However, when the detector pixel sizes are reduced, the impact of cardiac motion on CT images becomes more pronounced. Here, we investigated the effects cardiac motion on the image quality of a clinical prototype Si-PCD scanner in a dynamic heart phantom. METHODS: A series of 3D-printed vessels were created to simulate coronary arteries with diameter in the 1-3.5 mm range. Four coronary stents were set inside the d = 3.5 mm vessels and all vessels were filled with contrast agents and were placed inside a dynamic cardiac phantom. The phantom was scanned in motion (60 bpm) and at rest on a prototype clinical Si-PCD CT scanner in 8-bin spectral UHR mode. Virtual monoenergetic images (VMI) were generated at 70 keV and CT number accuracy and effective spatial resolution (blooming) of rest and motion VMIs were compared. RESULTS: Linear regression analysis of CT numbers showed excellent agreement (r > 0.99) between rest and motion. We did not observe a significant difference (p > 0.48) in estimating free lumen diameters. Differences in in-stent lumen diameter and stent strut thickness were non-significant with maximum mean difference of approximately 70 μm. CONCLUSION: We found no significant degradation in CT number accuracy or spatial resolution due to cardiac motion. The results demonstrate the potential of spectral UHR coronary CT angiography enabled by Si-PCD.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology and Imaging Sciences, Emory University, 1364 Clifton Road NE, Atlanta, GA 30322, USA.
- GE HealthCare, 3000 North Grandview Blvd, Waukesha, WI 53188, USA.
- Department of Radiology and Imaging Sciences, Emory University, 1364 Clifton Road NE, Atlanta, GA 30322, USA; Winship Cancer Institute, Emory University, 1364 Clifton Road NE, Atlanta, GA 30322, USA; Department of Biome…
Förderung
- Emory University
- GE Healthcare
Zitieren
APA
Holmes, T. W., Yin, Z., Stevens, G. M., Slavic, S., Okerlund, D. R., Maltz, J. S., & Pourmorteza, A. (2023). Ultra-high-resolution spectral silicon-based photon-counting detector CT for coronary CT angiography: Initial results in a dynamic phantom. Journal of Cardiovascular Computed Tomography, 17(5), 341-344. https://doi.org/10.1016/j.jcct.2023.08.003
Vancouver
Holmes TW, Yin Z, Stevens GM, Slavic S, Okerlund DR, Maltz JS, et al. Ultra-high-resolution spectral silicon-based photon-counting detector CT for coronary CT angiography: Initial results in a dynamic phantom. Journal of Cardiovascular Computed Tomography. 2023;17(5):341-344. doi:10.1016/j.jcct.2023.08.003
BibTeX
@article{Holmes2023,
author = {Holmes, Thomas Wesley and Yin, Zhye and Stevens, Grant M and Slavic, Scott and Okerlund, Darin R and Maltz, Jonathan S and Pourmorteza, Amir},
title = {Ultra-high-resolution spectral silicon-based photon-counting detector CT for coronary CT angiography: Initial results in a dynamic phantom},
journal = {Journal of Cardiovascular Computed Tomography},
year = {2023},
volume = {17},
number = {5},
pages = {341--344},
doi = {10.1016/j.jcct.2023.08.003}
}