What is the most suitable medicine ball mass for assessing maximal upper-extremity power in the seated single-arm horizontal push test?
Journal of Bodywork and Movement Therapies · 2025
DOI: 10.1016/j.jbmt.2025.09.023 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Bodywork and Movement Therapies, 2025. Verfasst von Matthieu Degot und 5 weiteren Autor:innen. Beteiligte Einrichtung: Universite Lyon 1, Laboratoire Interuniversitaire de Biologie de la Motricité, UR7424, Villeurbanne, France. Hauptthemen laut MEDLINE: Upper Extremity, Muscle Strength, Exercise Test. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Région Auvergne-Rhône-Alpes.
Abstract (Originalsprache)
INTRODUCTION: Different medicine ball (MB) masses are used for the unilateral MB push to indirectly determine upper-extremity power. This study aimed to identify the most suitable MB mass for assessing maximal upper-extremity power through the seated single-arm horizontal push test (SSAHPT). METHODS: Thirty-four athletes performed the SSAHPT with three different MB masses (1 kg, 3 kg, and 5 kg) and the unilateral ballistic bench press test. For each limb, the SSAHPT distance was determined, and the maximal power (Pmax) and force-velocity profile (SFv) were extracted from the unilateral bench press test. RESULTS: For the 1-kg and 3-kg MB, SSAHPT performance variation was explained by the variations of Pmax and Dominance (R2 = 0.82-0.86), with the effect of Pmax about 5.5 times greater than the effect of Dominance. For the 5-kg MB mass, SSAHPT performance variation was explained by the variations of Pmax, Dominance, and SFv (R2 = 0.85). The effect of Pmax was 5.3 and 1.6 times greater than the effect of Dominance and SFv, respectively. CONCLUSION: To limit the involvement of the athlete's force-velocity profile in SSAHPT performance with a 5-kg MB mass, it is advisable to use either a 1-kg or 3-kg MB mass when SSAHPT is employed to reflect maximal upper-extremity power.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Universite Lyon 1, Laboratoire Interuniversitaire de Biologie de la Motricité, UR7424, Villeurbanne, France.
- UnivSavoie Mont Blanc, Laboratoire Interuniversitaire de Biologie de la Motricité, EA 7424, F-73000, Chambéry, France.
- Universite Lyon 1, Laboratoire Interuniversitaire de Biologie de la Motricité, UR7424, Villeurbanne, France. Electronic address: Yoann.blache@univ-lyon1.fr.
Förderung
- Région Auvergne-Rhône-Alpes
Zitieren
APA
Degot, M., Rogowski, I., Dingome, A., Samozino, P., Morel, B., & Blache, Y. (2025). What is the most suitable medicine ball mass for assessing maximal upper-extremity power in the seated single-arm horizontal push test?. Journal of Bodywork and Movement Therapies. https://doi.org/10.1016/j.jbmt.2025.09.023
Vancouver
Degot M, Rogowski I, Dingome A, Samozino P, Morel B, Blache Y. What is the most suitable medicine ball mass for assessing maximal upper-extremity power in the seated single-arm horizontal push test?. Journal of Bodywork and Movement Therapies. 2025. doi:10.1016/j.jbmt.2025.09.023
BibTeX
@article{Degot2025,
author = {Degot, Matthieu and Rogowski, Isabelle and Dingome, Alexandre and Samozino, Pierre and Morel, Baptiste and Blache, Yoann},
title = {What is the most suitable medicine ball mass for assessing maximal upper-extremity power in the seated single-arm horizontal push test?},
journal = {Journal of Bodywork and Movement Therapies},
year = {2025},
doi = {10.1016/j.jbmt.2025.09.023}
}
EUVIMED