EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Reliability of a laser pointer device and photogrammetry in the evaluation of cervical flexion and side bending motions

María Alejandra Sánchez-Vera, Margareth Lorena Alfonso-Mora, Marisol Avellaneda Díaz, Laura Sofía Bravo Galvis, Angelica Vanessa Mora Barrero

Journal of Bodywork and Movement Therapies · 2025

DOI: 10.1016/j.jbmt.2025.05.052 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Bodywork and Movement Therapies, 2025. Verfasst von María Alejandra Sánchez-Vera und 4 weiteren Autor:innen. Beteiligte Einrichtung: Universidad de La Sabana, Campus del Puente del Común, Autopista Norte de Bogotá. Chía, Cundinamarca, Colombia. Hauptthemen laut MEDLINE: Photogrammetry, Range of Motion, Articular, Lasers, Cervical Vertebrae. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Universidad de La Sabana - Campus del Puente del Común.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: There are a variety of valid instruments for range of motion measurement, including computerized photogrammetry and laser devices. However, evidence of their effectiveness in measuring cervical range of motion is limited. OBJECTIVE: The purpose of the present study was to compare the reliability of photogrammetry (PG) and a laser pointer device (LPD) in the evaluation of cervical flexion and lateral bending motions in healthy subjects. METHODS: In this study, thirty healthy people were recruited. Cervical flexion and inclination range were assessed by PG and an LPD. For PG evaluation, two images were recorded for each movement assessed; images were taken on the same day within a 10-minute interval to evaluate reliability. For the LPD, two measurements were taken in a longitudinal direction for cervical flexion (CF), right side bending (RSB), and left side bending (LSB). RESULTS: PG showed high reliability for flexion and side bending movements between the two measurements CF ICC (intraclass correlation coefficient) = 0.99; RSB ICC = 0.97; LSB ICC = 0.99). Additionally, the LPD showed high reliability in all cervical movements evaluated (CF ICC = 0,99; RSB ICC = 0.99; LSB ICC = 0.99). The coefficient of variability indicated that flexion movement measurements were more homogenous in comparison to side bending movement measurements for both instruments. CONCLUSION: According to the results, PG and the LPD were shown to be reliable for the measurement of range of movement and the assessment of CF, RSB, and LSB in healthy people.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotogrammetryRange of Motion, ArticularLasersCervical VertebraeHumansFemaleAdultMaleReproducibility of ResultsYoung Adult

Stichwörter der Autor:innen

Cervical jointLaser pointer deviceMeasurementPhotogrammetryPhysiotherapyRange of motionReliability

Autor:innen und Institutionen

  • Universidad de La Sabana, Campus del Puente del Común, Autopista Norte de Bogotá. Chía, Cundinamarca, Colombia.
  • Universidad de La Sabana, Campus del Puente del Común, Autopista Norte de Bogotá. Chía, Cundinamarca, Colombia. Electronic address: margarethalmo@unisabana.edu.co.

Förderung

  • Universidad de La Sabana - Campus del Puente del Común

Zitieren

APA

Sánchez-Vera, M. A., Alfonso-Mora, M. L., Avellaneda Díaz, M., Bravo Galvis, L. S., & Mora Barrero, A. V. (2025). Reliability of a laser pointer device and photogrammetry in the evaluation of cervical flexion and side bending motions. Journal of Bodywork and Movement Therapies. https://doi.org/10.1016/j.jbmt.2025.05.052

Vancouver

Sánchez-Vera MA, Alfonso-Mora ML, Avellaneda Díaz M, Bravo Galvis LS, Mora Barrero AV. Reliability of a laser pointer device and photogrammetry in the evaluation of cervical flexion and side bending motions. Journal of Bodywork and Movement Therapies. 2025. doi:10.1016/j.jbmt.2025.05.052

BibTeX
@article{SnchezVera2025,
  author = {Sánchez-Vera, María Alejandra and Alfonso-Mora, Margareth Lorena and Avellaneda Díaz, Marisol and Bravo Galvis, Laura Sofía and Mora Barrero, Angelica Vanessa},
  title = {Reliability of a laser pointer device and photogrammetry in the evaluation of cervical flexion and side bending motions},
  journal = {Journal of Bodywork and Movement Therapies},
  year = {2025},
  doi = {10.1016/j.jbmt.2025.05.052}
}
Kostenlos starten →