Upper-Extremity physical performance tests in older adults: Reference values, reliability and measurement error
Journal of Bodywork and Movement Therapies · 2024
DOI: 10.1016/j.jbmt.2024.10.007 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Bodywork and Movement Therapies, 2024. Verfasst von Maria Eduarda Oliveira Novais und 6 weiteren Autor:innen. Beteiligte Einrichtung: Evangelical Faculty of Ceres, Ceres, Goiás, Brazil. Hauptthemen laut MEDLINE: Upper Extremity, Physical Functional Performance, Postural Balance. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 31 Literaturangaben.
Themen: Gerontologische Pflege
Abstract (Originalsprache)
BACKGROUND: Physical performance tests are reliable tools to assess aspects related to strength, power, and mobility. Unfortunately, few studies were performed with older adults. The main goal of this study was to describe reference values for the Closed Kinetic Chain Upper Extremity Stability Test (CKCUEST) and Upper Quarter Y Balance Test (UQYBT) in older adults and to determine differences based on sex. Reliability and measurement error were also established. METHODS: Test-retest design with a sample of 103 older adults. The CKCUEST (number of touches, normalized score, and power) and the UQYBT (reach in the medial, superolateral, and inferolateral direction, total excursion, and the composite score) were performed. The scores on both tests were adjusted using an analysis of covariance model. Reliability was determined using Intraclass Correlation Coefficient and error measurement through Standard Error of Measurement, Smallest Detectable Change, and Bland and Altman Plots. RESULTS: Normative values were provided. Males presented higher scores than females only in the medial reach of the UQYBT in the dominant limb (p < 0.001). Good reliability was found for the CKCUEST, while good to excellent reliability was found for the UQYBT; with the exception of the superolateral reach in the dominant limb. Absence of systematic error was presented. CONCLUSION: Normative data were provided and differences according to sex were found only in the UQYBT. Results demonstrated good to excellent reliability, except the superolateral reach in the dominant limb. Clinically acceptable absolute reliability values were found.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Evangelical Faculty of Ceres, Ceres, Goiás, Brazil.
- University of São Paulo, Ribeirão Preto, São Paulo, Brazil.
- Federal University of Goiás, Goiânia, Goiás, Brazil.
- State University of Goiás, Goiânia, Goiás, Brazil.
- University of Brasília, Brasília, Federal District, Brazil.
- University of Brasília, Brasília, Federal District, Brazil; University Center of the Federal District, Federal District, Brazil. Electronic address: joserobertofisio@gmail.com.
Zitieren
APA
Novais, M. E. O., Oliveira, A. S., Moreira, R. P., Barbosa, G. M. P., Lemos, T. V., Matheus, J. P. C., & de Souza Júnior, J. R. (2024). Upper-Extremity physical performance tests in older adults: Reference values, reliability and measurement error. Journal of Bodywork and Movement Therapies. https://doi.org/10.1016/j.jbmt.2024.10.007
Vancouver
Novais MEO, Oliveira AS, Moreira RP, Barbosa GMP, Lemos TV, Matheus JPC, et al. Upper-Extremity physical performance tests in older adults: Reference values, reliability and measurement error. Journal of Bodywork and Movement Therapies. 2024. doi:10.1016/j.jbmt.2024.10.007
BibTeX
@article{Novais2024,
author = {Novais, Maria Eduarda Oliveira and Oliveira, Anamaria Siriani de and Moreira, Rayanne de Paula and Barbosa, Glauber Marques Paraizo and Lemos, Thiago Vilela and Matheus, João Paulo Chieregato and de Souza Júnior, José Roberto},
title = {Upper-Extremity physical performance tests in older adults: Reference values, reliability and measurement error},
journal = {Journal of Bodywork and Movement Therapies},
year = {2024},
doi = {10.1016/j.jbmt.2024.10.007}
}
EUVIMED