EUVIMEDEUVIMED entdecken
Validierungsstudie

Validity and reliability of the modified four square step test in total HIP arthroplasty

Emel Tasvuran Horata, Fatma Eken, Murat Yesil, Ozal Ozcan

Journal of Bodywork and Movement Therapies · 2024

DOI: 10.1016/j.jbmt.2024.04.028 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Journal of Bodywork and Movement Therapies, 2024. Verfasst von Emel Tasvuran Horata und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physiotherapy and Rehabilitation, Afyonkarahisar Health Science University, Afyonkarahisar, Turkey. Electronic address: ethorata@gmail.…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Postural Balance. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: The Modified Four Square Step Test (mFSST) evaluates dynamic stabilization by using tape instead of canes to prevent people from tripping over obstacles and losing their balance. There was no study investigating reliability and validity in primary total hip arthroplasty (THA). This study aimed to evaluate the test-retest reliability, concurrent validity, and minimum detectable change in the mFSST for individuals with primary THA. METHOD: This study was cross-sectional in design. A total of 29 individuals aged 56.86 ± 10.14 years participated. The study used the test-retest method to determine the reliability of the mFSST and concurrent validity. The Timed Up and Go Test (TUGT) and Berg Balance Scale (BBS) were applied for concurrent validity. The minimum detectable change (MDC95) and the standard error measurement (SEM) were calculated. RESULTS: The mFSST showed excellent intra-rater reliability (ICC = 0.925). The SEM and MDC95 of the mFSST were 1.56 and 4.32. The test had a strong correlation with TUGT (r = 0.881) and BBS (r = -0.718) (p < 0.001). CONCLUSION: The mFSST is a valid and reliable assessment tool that can be used for individuals with primary THA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipPostural BalanceHumansMiddle AgedReproducibility of ResultsFemaleCross-Sectional StudiesMaleAgedAdultExercise Test

Stichwörter der Autor:innen

FallsPostural balanceValidation study

Autor:innen und Institutionen

  • Department of Physiotherapy and Rehabilitation, Afyonkarahisar Health Science University, Afyonkarahisar, Turkey. Electronic address: ethorata@gmail.com.
  • Department of Physiotherapy and Rehabilitation, Afyonkarahisar Health Science University, Afyonkarahisar, Turkey. Electronic address: fatmaeken08@gmail.com.
  • Department of Orthopaedics and Traumatology, Afyonkarahisar Health Sciences University, Afyonkarahisar, Turkey. Electronic address: drmurat17@hotmail.com.
  • Department of Orthopaedics and Traumatology, Afyonkarahisar Health Sciences University, Afyonkarahisar, Turkey. Electronic address: ozalozcan@yahoo.com.

Zitieren

APA

Horata, E. T., Eken, F., Yesil, M., & Ozcan, O. (2024). Validity and reliability of the modified four square step test in total HIP arthroplasty. Journal of Bodywork and Movement Therapies. https://doi.org/10.1016/j.jbmt.2024.04.028

Vancouver

Horata ET, Eken F, Yesil M, Ozcan O. Validity and reliability of the modified four square step test in total HIP arthroplasty. Journal of Bodywork and Movement Therapies. 2024. doi:10.1016/j.jbmt.2024.04.028

BibTeX
@article{Horata2024,
  author = {Horata, Emel Tasvuran and Eken, Fatma and Yesil, Murat and Ozcan, Ozal},
  title = {Validity and reliability of the modified four square step test in total HIP arthroplasty},
  journal = {Journal of Bodywork and Movement Therapies},
  year = {2024},
  doi = {10.1016/j.jbmt.2024.04.028}
}
Kostenlos starten →