EUVIMEDEUVIMED entdecken
Beobachtungsstudie

Comparison of sway meter and Kinovea software as a tool of measurement for the sway parameters during quiet standing: An observational study

Muhammed Rashid, Sherin Siby, Jerin Mathew, Sayed Asif Basha, Kavitha Raja

Journal of Bodywork and Movement Therapies · 2023-07 · 35 · 337-341

DOI: 10.1016/j.jbmt.2023.04.082 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Journal of Bodywork and Movement Therapies, 2023-07. Verfasst von Muhammed Rashid und 4 weiteren Autor:innen. Beteiligte Einrichtung: JSS College of Physiotherapy, Mysuru, Karnataka, 570004, India. Electronic address: rashidkpvld@gmail.com. Hauptthemen laut MEDLINE: Postural Balance, Standing Position. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Several attempts have been made to quantify postural sway, from simple observational techniques to advanced computer technology. Measuring sway using commercial motion tracking devices and force plates are expensive and not feasible in evaluation on non-standardised surfaces. Video cameras can be used as an affordable alternative to perform human motion capturing, and this data can be analysed using motion tracking software like Kinovea; a free, reliable software that provides valid data, and an acceptable level of accuracy in angular and linear measurements. This study evaluated the reliability of Kinovea software to measure the sway amplitude in comparison with sway meter. METHODS: Thirty-six young women were recruited by convenience to this prospective observational study. Sway amplitude of the participants were measured using a sway meter on three different surfaces, with eyes opened and closed conditions, using modified Lords sway meter and videography. Videos were later analysed using Kinovea motion analysing software. The quantitative data of sway parameters were analysed for reliability using intraclass-correlation co-efficient and Bland Altman plot. RESULTS: There was an excellent correlation (>0.90) between the sway measurement values obtained from both methods irrespective of the surfaces. But the reliability was greater for the medio-lateral sway on the pebbled surfaces (0.981), and least for the anterior posterior sway on the same surface. CONCLUSION: This study concludes that, there is an excellent reliability for the video based sway analysis using Kinovea software. Hence this method can be used as an affordable alternative to measure the sway parameters.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Postural BalanceStanding PositionHumansFemaleReproducibility of ResultsSoftwareAccidental Falls

Stichwörter der Autor:innen

AmbulationBalanceFallsPostural swayUneven terrain balance

Autor:innen und Institutionen

  • JSS College of Physiotherapy, Mysuru, Karnataka, 570004, India. Electronic address: rashidkpvld@gmail.com.
  • Physical Medicine and Rehabilitation, Zale Lipshy Pavillion - William P. Clements Jr. University Hospital, University of Texas, Southwestern, Medical Centre in Dallas, Texas, USA.
  • Centre for Health, Activity, And Rehabilitation Research, School of Physiotherapy, University of Otago, Dunedin, New Zealand; Department of Anatomy, School of Biomedical Sciences, University of Otago, Dunedin, New Zeala…
  • JSS College of Physiotherapy, Mysuru, Karnataka, 570004, India.

Zitieren

APA

Rashid, M., Siby, S., Mathew, J., Basha, S. A., & Raja, K. (2023). Comparison of sway meter and Kinovea software as a tool of measurement for the sway parameters during quiet standing: An observational study. Journal of Bodywork and Movement Therapies, 35, 337-341. https://doi.org/10.1016/j.jbmt.2023.04.082

Vancouver

Rashid M, Siby S, Mathew J, Basha SA, Raja K. Comparison of sway meter and Kinovea software as a tool of measurement for the sway parameters during quiet standing: An observational study. Journal of Bodywork and Movement Therapies. 2023;35:337-341. doi:10.1016/j.jbmt.2023.04.082

BibTeX
@article{Rashid2023,
  author = {Rashid, Muhammed and Siby, Sherin and Mathew, Jerin and Basha, Sayed Asif and Raja, Kavitha},
  title = {Comparison of sway meter and Kinovea software as a tool of measurement for the sway parameters during quiet standing: An observational study},
  journal = {Journal of Bodywork and Movement Therapies},
  year = {2023},
  volume = {35},
  pages = {337--341},
  doi = {10.1016/j.jbmt.2023.04.082}
}
Kostenlos starten →